background image

 

6. UNPACKING AND INSTALLATION 

6.1 UNPACKING 

Once the suitable location for installation has been identified, open the package and remove the pump. Check that it was not 
damaged during transport or storage. The packaging material does not require special disposal precautions as it  is not in any 
way dangerous or polluting. Refer to the local regulations for disposal. 

 

6.2 INSTALLATION  

Pump assembly operations are not required. 
Allow a sufficient amount of space for installation, leaving a minimum perimetric space of 100 mm (3,93 in.). 
For  wall-mounting,  suitable  space  must  be  provided  (see  the  installation  diagram)  to  prevent  abnormal  positions  or  the 
possibility of impacts; install the pump at shoulder height. Then, the pump must be connected hydraulically to the machine and 
the tank must be filled (making sure not to exceed the maximum visual level). 
Empty the tank during the disassembly phase and disconnect the hydraulic part. 

 
 
7. INSTRUCTIONS FOR USE 

7.1 PRELIMINARY CHECKS 

-

 

Check the integrity of the pump. (The unit may only be opened and repaired by specialised personnel). 

-

 

Check that the hydraulic connection was carried out correctly. 

-

 

Fill the tank with lubricant free of impurities. 

 

7.2 USING THE PUMP 

Pump operation is very simple: simply pull the lever with a decisive and complete movement and release it. We recommend 
carrying out a few cycles to bleed the air from the system. 

 

It is prohibited to use the pump if submersed in fluids or in a particularly aggressive or explosive/inflammable environment 
if not previously prepared for that purpose by the supplier. 

 

Use protective gloves or glasses as specified in the safety sheet for the lubricating oil. 

 

DO NOT use aggressive lubricants with NBR gaskets. In the case of doubt, contact the technical office. 

 

Do not ignore the hazards to health and comply with the health regulations.  

 
 

8. PROBLEMS AND SOLUTIONS 
 

ANOMALY 

CAUSE 

SOLUTION 

The pump does not deliver 

or does not deliver the 

required quantity 

 

The pump intakes air because the tank is 

empty 

Refill the tank and bleed the air from the system 

The fittings are loose 

Carefully  tighten  al  the  fittings  making  sure  there 

are no leaks 

The pump does not deliver 

at the required pressure 

 

Pump deteriorated 

Replace the pump 

By-pass valve decalibrated 

Turn the pressure adjustment screw  

 

9. MAINTENANCE PROCEDURES 

The pump was designed and built in order to minimise maintenance requirements. 
To simplify maintenance, it is recommended to install it in an easy to reach position. 
Periodically check the pipe joints and always keep the pump clean to detect any leaks or defects. 
The machine does not require any special equipment for any control and/or maintenance activity. It is recommended to use 
tools and personal protective devices suitable for use (gloves) and that are in good condition according to current regulations to 
prevent damage to people or machine parts.   
 

 
 

 
In the case of doubts and/or problems that cannot be solved, do not try to discover the reason by disassembling machine parts, 
but contact the DROPSA S.p.A technical office. 
 

ATTENTION: make sure that the hydraulic power supply is disconnected before carrying out any maintenance work. 

 

Summary of Contents for 3106000

Page 1: ...ATION 4 TECHNICAL SPECIFICATIONS 5 PUMP COMPONENTS 6 PUMP UNPACKING AND INSTALLATION 7 INSTRUCTIONS FOR USE 8 PROBLEMS AND SOLUTIONS 9 MAINTENANCE PROCEDURES 10 DISPOSAL 11 ORDER INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORT 14 PRECAUTIONS FOR USE 15 GUIDELINES FOR USE 16 WARRANTY 17 DISTRIBUTORS C2157IE WK 39 10 http www dropsa com ...

Page 2: ...o use this apparatus You must read and look after it carefully making sure that it is available at all times for the operators who intend to consult it 2 GENERAL DESCRIPTION The hand operated pump 3106000 is particularly suggested due to its compact form and versatility when used with press lubrication systems machine tools reducers guides chains etc The hand operated pump 3106000 has a built in r...

Page 3: ...l Pumping system Piston Maximum operating pressures 30 bar Tank capacity 1 L Flow rate 10 cc shot Outlet connection G1 4 BSP Temperature of use 5 40 C Permitted lubricants Mineral lubricating oil min 32 cSt Grease max NLGI000 Maximum driving force 20 Kg Bypass Adjustable 0 30 bar Storage temperature 20 65 C PUMP COMPONENTS 1 Activation lever 2 Loading cap 3 Outlet 4 Tank 5 Distributor block 6 Fast...

Page 4: ...explosive inflammable environment if not previously prepared for that purpose by the supplier Use protective gloves or glasses as specified in the safety sheet for the lubricating oil DO NOT use aggressive lubricants with NBR gaskets In the case of doubt contact the technical office Do not ignore the hazards to health and comply with the health regulations 8 PROBLEMS AND SOLUTIONS ANOMALY CAUSE SO...

Page 5: ...emolishing the machine the identification plate and all other documents must be destroyed 11 ORDER INFORMATION 11 1 STANDARD VERSIONS 11 2 ACCESSORIES 12 DIMENSIONS ITEM Tank capacity Calibration pressure Flow rate CODE HAND OPERATED PUMP 1 Lt 30 BAR 10 cc 3106000 ITEM DESCRIPTION CODE PRESSURE GAUGE FITTING 0 60 bar 0020553 3085250 MOUNTING BRACKET KIT 3106117 MOUNTING BRACKET OPTIONAL ...

Page 6: ...in the lubrication circuits is normally not an inflammable liquid It is however necessary to adopt all the possible measures to prevent that it comes into contact with very hot parts or open flames Pressure Before each operation make sure there in every branch of the lubrication circuit that there is no residual pressure that could cause oil to spray when disassembling fittings or components After...

Page 7: ...ct with the fluid must be foreseen by the user the operator must be equipped with suitable PPE Use of unsuitable lubricant Main fluids that are not permitted Fluid Danger Lubricants with abrasive additives Extensive wear of the contaminated parts Lubricants with silicone additives Pump seizure Petrol solvents inflammable liquids Fire explosion damage to the gaskets Corrosive substances Pump corros...

Page 8: ... of subject product to an authorized Dropsa Sales Service location we will then either repair or replace such product s at out option and if determined to be a warranted defect we will perform such necessary product repairs or replace such product s at our expense Dropsa S p A reserves to right to charge an administration fee if the product s returned are found to be not defective This limited war...

Page 9: ...uk dropsa com Dropsa do Brazil Ind E Com Ltda Rua Sobralia 175 Sao Paulo Brazil Tel 55 011 5631 0007 Fax 55 011 5631 9408 E mail salesbr dropsa com Dropsa USA Inc 6645 Burroughs Ave 48314 2132 Srerling Hts Mi Us USA Tel 1 586 566 1540 Fax 1 586 566 1541 E mail salesusa dropsa com Dropsa Lubrication Systems Nr 8 Dongxing Road Songjiang Industrial Zone Shanghai Co Ltd Tel 86 021 67740275 Fax 86 021 ...

Reviews: