Parachute Manual DRS-M600_EN
©2021 Drone Rescue Systems GmbH
24/27
Table 3 shows a list of available parameters.
Parameter
Def.
Range
Unit Description
MAX_BANK_ANGLE
55
20 - 90
deg Deploy when bank angle exceeds
set value. Set to zero to disable
this feature.
MAX_SINKRATE
700
500 - 2550
𝑐𝑚
𝑠
Deploy when vertical velocity
exceeds set value. Set to zero to
disable this feature.
MAX_YAWRATE
300
100 - 490
𝑑𝑒𝑔
𝑠
Deploy when yaw rate exceeds
set value. Set to zero to disable
this feature.
MIN_FREEFALL_ACC
300
5 - 500
𝑐𝑚
𝑠 ∗ 𝑠
Deploys when the norm of the
acceleration vector drops below
this value. Set to zero to disable
this feature.
DISABLE_POWER_BAD
0
0 / 1
-
0: deploy when a power loss is
detected
1: Power loss detection is
disabled
AUTOMATIC_DISABLE
0
0 / 1
-
0: Deploy when enabled
parameters exceed their set
value.
1: System will NOT deploy when
enabled parameters exceed
set value. Only manual deploy
works.
LOGGING_FROM_POWER_ON
1
0 / 1
-
0: Logging from takeoff until
power off.
1: Logging from power on until
power off.
MOTOR_OFF_DELAY
0
0
–
10000
ms
Delay parachute deployment for
configured time. This refers to
manual
and
automatic
deployment.
SERIAL_INTERFACE
0
0 - 4
-
Must be set to 0 for DRS-M600.
Table 3 Available parameters to customize configuration
Caution:
Be careful when choosing the values. Use proper values for your UAV and
application. Using improper parameter values may cause the parachute to fail from
deploying as well as unwanted deployments.
System Time
The DRS-M600 is capable of naming the log-files based on the current date and timestamp.
Therefore, the system’s time has to be set in advance. This is done once after fabrication but