Myriad II Installation and Operation Manual
31
7.2
Clearances to Walls and Ceiling
The clearances to combustible walls may be slightly different in Canada and the U.S.A.
and may also differ depending on whether you use single or double wall flue pipe. Please
be sure to choose the correct clearance for your location and type of flue pipe. See figure
Clearances to combustible materials and floor protection to match each letter to a
clearance.
APPLIANCE CLEARANCES
(INSTALLATION WITH SINGLE
WALL PIPE CONNECTOR)
CANADA
USA
A
15" (381 mm)
9" (229 mm)
B
24" (610 mm)
24" (610 mm)
C
16" (406 mm)
16" (406 mm)
K
48" (1220 mm)
48" (1220 mm)
L
84" (213 cm)
84" (213 cm)
APPLIANCE CLEARANCES
(INSTALLATION WITH DOUBLE
WALL PIPE CONNECTOR)
CANADA
USA
A
6" (152 mm)
6" (152 mm)
B
24" (610 mm)
24" (610 mm)
C
16" (406 mm)
16" (406 mm)
K
48" (1220 mm)
48" (1220 mm)
L
84" (213 cm)
84" (213 cm)
If the above clearances are met, then the distances measured from the flue outlet
will be:
DISTANCES* FROM PIPE
CONNECTOR TO THE
COMBUSTIBLE MATERIALS
CANADA
USA
D
18 1/2" (470 mm)
12 1/2" (318 mm)
E
33" (838 mm)
33" (838 mm)
F
24 1/2" (622 mm)
24 1/2" (622 mm)
DISTANCES* FROM PIPE
CONNECTOR TO THE
COMBUSTIBLE MATERIALS
CANADA
USA
D
9 1/2" (241 mm)
9 1/2" (241 mm)
E
33" (838 mm)
33" (838 mm)
F
24 1/2" (622 mm)
24 1/2" (622 mm)
*The pipe distances listed in this table refer to the distances obtained when the
stove is installed in accordance with the appliance clearances above mentioned.
However, you can install the stove at reduced clearances; follow the instructions in
Section 7.4: Reducing Wall and Ceiling Clearances Safely. Where they are followed,
the new distance of the pipe to combustible materials must be respected in the
appropriate certification of the pipe.