VF61 Programming Chart
Model VF61 ___________________ SN: _______________________
Code
No.
Function Abbrev.
Function setting item
Unit
Setting range (Setting Resolution)
Change
during
operation
Default
User
value
80
Acc2.Time
Acceleration (2) time
Sec.
.1 to 3600
Impossible
30 Sec
81
Dec2.time
Deceleration (2) time
82
Acc3.Time
Acceleration (3) time
83
Dec3.Time
Deceleration (3) time
84
Acc4.Time
Acceleration (4) time
85
Dec4.Time
Deceleration (4) time
86
Preset3.F
Preset (3) frequency
Hz
-Top.F to +Top.F
Possible
0 Hz
87
Preset4.F
Preset (4) frequency
88
Preset5.F
Preset (5) frequency
89
Preset6.F
Preset (6) frequency
90
Preset7.F
Preset (7) frequency
91
Term-9.Sel
Terminal 9 (multifunction analog output)
selection
N/A
Vout Output voltage (a)
Iout Output current (b)
Torq Torque
current(c)
Fout Output frequency (d)
Internal Mon justing monitor for internal
use (e)
Possible
(b)
92
Carrier.F
Carrier frequency
kHz
4 to 15
Possible
15 kHz
93
L-SP.Adjust
Line speed indication adjustment
N/A
0 to 3200
Possible
0
94
STB.Adjust
STB adjustment
%
0 to 100
Possible
0%
95
OL.Pre-Alarm
Overload pre-alarm setting
%
0 to 100
Possible
50%
96
LED-Disp.Sel
Inverter LED indication item selection
N/A
Fout Output frequency (a)
Fref Reference frequency (b)
Iout Output current (c)
Vout Output voltage (d)
Torq out Torque current (e)
Vdc DC voltage (f)
Motor Speed Synchronous motor RPM (g)
OL counter Overload counter (h)
Line Speed Line Speed (i)
ROM Version ROM Version
(j)
Possible
(a)
97
ALM-data cir
Fault history clear
N/A
yes (a)
no (b)
Impossible
(b)
Code group special settings
Code
No.
Function Abbrev.
Function setting item
Unit
Setting range (Setting Resolution)
Change
during
operation
Default
User Value
17
Motor.Cap
Rated motor capacity
kW
.4 to rated inverter capacity
Impossible
N/A
18
Motor.V
Rated motor voltage
V
(400V class) 320 to 480
Impossible
400V
V
(200V class) 160 to 240
Impossible
200V
19
Motor.I
Rated motor current
A
1 to Rated inverter current
Impossible
N/A
20
Motor.F
Rated motor frequency
Hz
30 to 400
Impossible
60Hz
21
Motor.RPM
Rated motor RPM
rpm
300 to 24000
Impossible
1740rpm
22
Motor.Pole
Number of poles of the motor
N/A
2,4,6,8 (pole)
Impossible
N/A
23
Motor.R1drop
Primary resistance drop of the motor
%
0 to 25
Impossible
5%
24
DB.V
Dynamic Brake operating voltage
V
(400V class) 540 to 740
Possible
720V
V
(200V class) 270 to 370
Possible
360V
25
0 to 10V Gain
Frequency setting input + side (0V to
10V) gain
%
50 to 150
Possible
100%
26
-10 to 0V Gain
Frequency setting input - side (-10V to
0V) gain
%
50 to 150
Possible
100%
27
Term-9.Gain
Terminal 9 (analog output) gain
%
50 to 150
Possible
100%
28
Term-9.Ofset
Terminal 9 (analog output) offset
%
-5 to +5
Possible
0%
29
VDC.DET.Gain
DC voltage detection gain
%
90 to 110
Possible
100%
30
CRT.DET.Gain
Output current detection gain
%
50 to 150
Possible
100%
31
FCL.Level
FCL level
%
80 to 100
Possible
100%
Special Setting 2 (Sp.set-2)
Code
No.
Function Abbrev.
Function setting item
Unit
Setting range (Setting Resolution)
Change
during
operation
Default
User Value
17
4 to 20 out.Sel
4 to 20 mA output selection
N/A
Vout Output voltage (a)
Iout Output current (b)
Torq Torque current (c)
Fout Output frequency (d)
Internal Mon Adjustment monitor for internal
use (e)
Possible
(b)
18
4 to 20 out.gain 4 to 20 mA output gain
%
50 to 150
Possible
100%
19
4 to 20
out.Ofset
4 to 20 mA output offset
%
-1 to +1
Possible
0%
20
ISOin.Gain
Insulated input gain
%
50 to 150
Possible
100%
21
ISOin.Ofset
Insulated input offset
%
-1 to +1
Possible
0%
22
PG-Pulse
Number of PG pulses
P/R
100 to 2400
Impossible
600 P/R
23
ASR.P-Gain
ASR proportional gain
N/A
1 to 200
Possible
5
24
ASR.I-Time
ASR integral time
mS
.20 to 200
Possible
10 mS