2
–
Hybrid-Power
Content
Fire Warning
3
Safeguards
4
Introduction
6
Installation
8
Pump Functions
9
Storage
10
Damage Prevention
Moving and Handling
Cleaning
11
Maintenance
13
Troubleshooting
14
Technical Description
15
Warranty
16
Page 1: ...Hybrid Power User Manual...
Page 2: ...p step down alternating therapy to repair and maintain healthy skin cells as well as providing a comfortable and stable platform When the Hybrid Power system is in use with the pump it is suitable for...
Page 3: ...tent Fire Warning 3 Safeguards 4 Introduction 6 Installation 8 Pump Functions 9 Storage 10 Damage Prevention 10 Moving and Handling 10 Cleaning 11 Maintenance 13 Troubleshooting 14 Technical Descripti...
Page 4: ...ause damage to the mattress system Patient clothing bed sheets and other items may be combustible and could catch fire Failure to observe this warning could result in a severe fire property damage phy...
Page 5: ...to a service centre for examination and repair 5 Keep the cord away from heated surfaces 6 Never block the air opening of this product or place it on a soft surface such as a bed or couch where their...
Page 6: ...5 Hybrid Power Disposal of Electrical Electronic Equipment WEEE Product conforms to all relevant standards See Declaration of Conformity...
Page 7: ...cells to be built on as well as providing a support structure during patient transfer The support foam also contains specially engineered castellation s in the side walls to allow the mattress to ben...
Page 8: ...unit This pump has been specifically designed for the Hybrid application This compact and light weight pump is easy to transport and can be easily cleaned down to aid infection control Intended use Th...
Page 9: ...floor 6 Join the connectors on the mattress feed pipes to the side of the pump NOTE Ensure the feed pipes on the mattress are not kinked or tucked under the mattress as this will restrict airflow 7 P...
Page 10: ...d by pressing this button The pump will automatically revert back to alternating mode after 20 minutes Alternate One in two cycle this function will provide optimum pressure relief Lock Out After 5 mi...
Page 11: ...tra care not to puncture the cover as this will allow fluid ingress and ultimately contaminate the foam core To prevent the cover from being punctured and or damaged x Do not place sharp objects such...
Page 12: ...ct cannot be decontaminated therefore it is recommended that any contamination must result in the foam being replaced WARNING Do not use phenolic or biological based cleaning solutions Do not use any...
Page 13: ...ould be followed by a cold rinse and extraction Drying Mattress inners and tube sets should be wiped with a clean and dry cloth before reinserting Mattress covers can be tumble dried on a low heat set...
Page 14: ...be checked regularly to ensure they remain fit for purpose clinically effective and pose no risk of infection to either the patient or the carer Drive DeVilbiss Healthcare Ltd recommend that a thorou...
Page 15: ...ls are secure x Assess the cells for any punctures which maybe causing a leak Patient is bottoming out x Pressure setting may be inadequate adjust comfort range No air is being produced from some of t...
Page 16: ...ge x Continuous operation Mattress Specification Dimensions 1980 x 880 x160mm Weight 16Kg Max Patient Weight 254kg with a pump Top Cover Material Xtreme fabric PU coated fabric substrate Cell Material...
Page 17: ...our products and our assurance to the customer In the event of a defect covered by this warranty we will at our option supply parts or replace the device This warranty does not cover device failure du...
Page 18: ...ve our customers the freedom to live independently This encompasses their daily home life and provides them with the opportunity to enjoy an outing with family and friends Our goal is to develop a ran...