Drive AKKULIFT Operating Instructions Manual Download Page 18

________________________________________________________________________________________ 

 
18 of 24 

Supplement 

 

Technical Data 

 

AKKULIFT

®

 

Overall length (backrest in reclined position) 

860 mm 

Overall width (seat incl. side flaps)   

 

700 mm 

Width of seat   

 

 

 

 

370 mm 

Depth of seat   

 

 

 

 

450 mm 

Overall length of seat  

 

 

 

580 mm 

Sitting height min. 

 

 

 

 

approx. 80 mm 

Sitting height max. 

 

 

 

 

approx. 420 mm 

Height of backrest 

 

 

 

 

approx. 560 mm 

Width of backrest 

 

 

 

 

approx. 320 mm 

Angle of inclination (backrest) 

 

 

12  to 40  

Width of base plate   

 

 

 

approx. 310 mm 

Length of base plate   

 

 

 

approx. 545 mm

 

Load, max.      1

4

0 kg 

Weight, incl. storage battery   

 

 

approx.14,8 kg 

Motor unit (without battery)   

 

 

approx. 7.0 kg 

Seat unit 

 

 

 

 

 

approx. 7,7 kg 

Duration of lifting/lowering movement 

 

approx. 25 seconds (each)

 

Operating voltage 

 

 

 

 

12 V 

 

 

 

 

 

 

Storage battery 

 

 

 

 

12 V 

  2 - 2.6 Ah (rechargeable) 

 
 

Battery Charging Unit for 12-V Storage Batteries, black

  

Type   

 

 

 

 

 

Model HK-F304-T144 
Input voltage   

 

 

 

  

UK: 230 V-/50 Hz  

Output voltage 

 

 

 

 

12 V-/300 mA 3.6 VA 

Charge termination   

 

 

 

14.4 V +/- 2% 

Voltage limit   

 

 

 

 

fixed at 14.4 V 

Connection 

 

 

 

 

 

3.5 mm phone plug 

Housing material 

 

 

 

 

ABS 

Dimensions 

 

 

 

 

 

45 x 64 x 28 mm 

Indicators 

  

 

 

 

LED red, 

fast charge 

LED green

, trickle charge or no battery connected

 

Weight  

 

 

 

 

 

approx. 0.1 kg 

 
 

General Operating Conditions (of AKKULIFT) 

Ambient temperature  

 

 

 

+10...+ 50  C 

Relative air humidity   

 

 

 

10...100 % 

Air pressure   

 

 

 

 

700 hPa...1060 hPa 

 

Transport and Storage 

Temperature   

 

 

 

 

+10...+ 30 C 

Relative air humidity   

 

 

 

10...100 % 

Air pressure   

 

 

 

 

700 hPa...1060 hPa

 

 

 
 
 
 
 
 

Summary of Contents for AKKULIFT

Page 1: ...Operating Instructions AKKULIFT Bathlift Riviera UK AKKULIFT Bathlift Riviera Transfer UK...

Page 2: ...7 Operating the AKKULIFT in the bath 9 Manual Control 10 Removing the lift from the bathtub 11 Maintenance and Care 13 Maintenance of the AKKULIFT 13 Assembly of new cushion plugs for AKKULIFT 15 Mai...

Page 3: ...g the manual control which floats on the water comfortable raising and lowering is possible in the normal sitting position AKKULIFT can also be adjusted to variable positions The drive is housed in a...

Page 4: ...sporting AKKULIFT If AKKULIFT has been exposed to low temperatures for a longer period of time e g longer storage in a vehicle during the winter allow it to warm up to room temperature before use in o...

Page 5: ...the supplement to these operating instructions In the event of a failure please read the supplement to these operating instructions and the Troubleshooting chapter Make sure to observe the informatio...

Page 6: ...ler Unpack the charging unit first then unpack the remaining parts The shipping carton should be kept for later use i e transporting and storing AKKULIFT Prior to starting up the device for the first...

Page 7: ...s the mid suction cup to the bottom of the bathtub and fixes it into position see Figure 1 4 Place the backrest with cover on the frame in the bathtub Then insert the guide pins of the backrest into t...

Page 8: ...htub wall on the side of the backrest is vertical and con sequently there is a risk that the backrest is pushed against it the lift must be installed outside the bathtub and must be driven to its uppe...

Page 9: ...utomatically When the button is released the lift is stopped making it possible to move to intermediate stop positions Attention Release the blue button immediately if the backrest is pushed against t...

Page 10: ...the storage battery must be charged immediately see Charging the Storage Battery on page 17 The charging status of the storage battery is monitored by electronic control elements After one lifting mov...

Page 11: ...lly in its end position Make sure that the backrest does not push against the wall of the bathtub Then remove the battery from the battery compartment 1 The backrest is unlocked by pressing the red bu...

Page 12: ...arrow shown in Figure 11 Note The backrest cannot be removed from the frame when it is completely folded down to the seat because the backrest is then in a locked position again 4 Remove all 5 suctio...

Page 13: ...quest Maintenance of the AKKULIFT AKKULIFT is equipped with bearings and running surfaces which are completely maintenance free and do not require any lubrication However the lift should be cleaned th...

Page 14: ...may stain the covers failure to undertake regular cleaning of your covers will cause your covers to discolour Note Any form of discolouration is not covered under warranty scheme as they are consumabl...

Page 15: ...mobile use of the device Take the storage battery out of the battery compartment and store it separately 1 Secure the lift against sliding or slipping during transportation 2 If AKKULIFT was exposed...

Page 16: ...ned with mild detergents which are free from solvents or by means of a damp cloth Make sure that no liquid penetrates the charging unit Before starting up the charging unit again always make sure that...

Page 17: ...that the charging indicator will flash green The battery is charged and ready for use 5 Always pull the line power cord first 6 Disconnect the charging unit from the battery 7 After the charging unit...

Page 18: ...otor unit without battery approx 7 0 kg Seat unit approx 7 7 kg Duration of lifting lowering movement approx 25 seconds each Operating voltage 12 V Storage battery 12 V 2 2 6 Ah rechargeable Battery C...

Page 19: ...st dealer DO NOT USE THE DEVICE ANY LONGER Storage battery failure Insert new storage battery Lift creates loud noise Drive failure Contact your specialist dealer DO NOT USE THE DEVICE ANY LONGER Lift...

Page 20: ...sed and maintained as above Failure to do this can reduce the device life expectancy The life expectancy does not constitute an additional warranty Warranty Our warranty for AKKULIFT will be in accord...

Page 21: ...anual Control 400 600 Charging unit black 400 uk 350 Stopper and washer for Cover Classic Comfort white 415 252 Stopper and washer for Cover Classic Comfort white 415 312 Stopper and washer for Cover...

Page 22: ...the year and week of production of AKKULIFT Lift No Indicates the serial number of AKKULIFT Charging unit There are two entries which are very important for maintenance repair or warranty These entrie...

Page 23: ...r 21 Inserting the AKKULIFT into the Bathtub 7 Installation and Use 6 Maintenance of the AKKULIFT 13 Maintenance of the Charging Unit 16 17 Manual Control 10 Mobile use of the device 15 ON button 9 Op...

Page 24: ...9 0 7562 9724 25 Web www drivemedical de Mail info drivemedical de Drive Medical Limited Ainleys Industrial Estate Elland West Yorks HX5 9JP Phone 44 0 1422 31 44 88 Fax 44 0 1422 31 44 89 Web www dri...