background image

Place cone inside 

and fill medication.

4.    OPERATING YOUR NEBULIZER

4

Operating Cautions:

Storage Cautions:

Cleaning Cautions:

1.

1.

Note: 

Prior to initial operation, the nebulizer should be thoroughly cleaned.

Only connect this product to an appropriate voltage outlet for your model.

2. Do not run this product unattended.
3. Never operate the Airial Voyager™ Portable Nebulizer if it has a damaged 

cord, plug, or battery or if it has been dropped into water. If for any reason 

this unit does not work properly, promptly return it to an authorized service 

center for repair.

4. If any abnormalities occur, discontinue use immediately until the unit has

been examined and repaired.

5. Always unplug the product immediately after use.
6. Never block the air openings of the main unit or place it where the air

openings may be obstructed.

7. This product should always be operated under close adult supervision.

Do not store the unit under direct sunlight, high temperature or humidity.

2. Keep the unit out of reach of small children.
3. Always keep the unit unplugged while not in use.

1. Do not immerse the unit in water. It may damage the unit.

1. Place your Airial Voyager™ Portable Nebulizer on a flat and stable surface. Be

sure that you can easily reach the controls when you are seated.

2. Gently twist the top part of the nebulizer cup counter-clockwise to disassemble

the nebulizer cup.

3. Fill the bottom section of the nebulizer

cup with the medication prescribed by 

your physician. Be sure that the cone is 

put inside the bottom section.

4. Gently twist the top part clockwise to 

reassemble the nebulizer cup. Be sure 

the two sections fit well.

5. Attach one end of air tube to the base of the nebulizer cup.
6. Attach mouthpiece or mask per your choice to the top section of nebulizer cup.
7. Your nebulizer operates by using one of two power choices: the AC Adapter 

or the Battery pack.

2. Disconnect the unit from the electrical outlet before cleaning.
3. Clean all necessary parts after each use as instructed in this guidebook.

Summary of Contents for Airial Voyager MQ5300

Page 1: ...i f d rale tats Unis exige que cet appareil soit vendu par ou la demande d un m decin PRECAUCI N Las leyes federales EE UU restringen la venta de este dispositivo s lo por orden de un m dico CAUTION F...

Page 2: ...e you with many years of reliable treatment This product is developed for the successful treatment of asthma allergies and other respiratory disorders It creates a stream of air that travels through a...

Page 3: ...it Never operate the unit if it has any damaged parts including power cord or if it has been dropped or submersed in water Promptly send it to a service center for examination and repair 1 2 The unit...

Page 4: ...e the unit under direct sunlight high temperature or humidity 2 Keep the unit out of reach of small children 3 Always keep the unit unplugged while not in use 1 Do not immerse the unit in water It may...

Page 5: ...s and hold the Open Lock button and slide the battery away from you to engage Release the Open Lock button 3 Place the rubber skid resistant base into your carry case for storage and later use 4 Press...

Page 6: ...zer cup mouthpiece and mask with water 4 Dry them with clean soft towel or let them air dry 5 Reassemble the nebulizer cup when completely dry and put these parts in a dry sealed container It is recom...

Page 7: ...k Nebulizer Air Tube Mouthpiece Filters 5 PCs Protection against electric shock Class II Equipment Type BF applied parts Mouthpiece and mask Protection against harmful ingress of water Degree of safet...

Page 8: ...ession of our confidence in the materials and workmanship of our products and our assurance to the consumer of years of dependable service This warranty does not cover device failure due to owner misu...

Page 9: ...www drivemedical com Drive Medical 99 Seaview Boulevard Port Washington NY 11040 t 877 224 0946 f 516 996 4601...

Reviews: