Battery box   

Control box with 

internal charger 

Emergency stop button 

LCD display 

Insert the plug of 
power cord in control 
box and the other end 
to a wall outlet.

Connect the plug of 

Handset 

Connect the plug 

of Actuator

   

 

 

 

 

 

 

 

Maintenance:

     

        It is extremely important that the lift be inspected before each use.    The following items 

need to be checked: 

a.  All nuts and bolts should be tight. 

b.  The lifter should move freely with caster brakes off. 

c.  Check the brakes on the rear casters for proper operation. 

d.  Make sure base adjustment mechanism is operating easily. 

e.  Double check to ensure the “U” bracket at the end of the boom and the “S” hook on the 

hanging bar are secured tightly. 

f.  Work the Linak Actuator to ensure that the battery still has enough power.    When battery 

is 50% below full capacity, it will give “ beep” warning and need to re-charge immediately. 

g.  Before initial use, place a drop of oil on the following areas. 

(1) Where mast and boom connect, hanging bar hook, pump handle hinge, and caster 

axles, 

(2) Where pump and boom attach, 

(3) Lubricate as above every two to three months. 

 

 

* We reserves the right to make technical changes without notice 

Manufactured For: 

Drive Medical Design an
www.drivemedical.com 

d Manufacturing 

 

 

Summary of Contents for 13246

Page 1: ...USER MANUAL Item 13246 Stand Aid Lift Drive Medical Design and Manufacturing www drivemedical com ...

Page 2: ... qualified professional z The lift must be used by a caregiver with proper training to work with the person to be transferred z Only trained and qualified caregivers should transfer a person Do not attempt to use the lift if you have not been properly trained to do so z Always be prepared before attempting to transfer a person z Do not use a sling that is not recommended for the lift z Do not stor...

Page 3: ...ts from the carton and place on the floor taking care to protect the finish from damage 2 Place the chassis in a clear space and apply the rear bakes Attach the foot plate to the base Drive Medical Design and Manufacturing www drivemedical com ...

Page 4: ...3 Fit the mast and boom assembly into the base socket Tighten the mast assembly with the drive screw Drive Medical Design and Manufacturing www drivemedical com ...

Page 5: ...Tighten up screw Assemble actuator bottom and top Insert the pin chain through actuator top Drive Medical Design and Manufacturing www drivemedical com ...

Page 6: ...Fit control box onto bracket on mast Tight up control box Fit battery onto control box Drive Medical Design and Manufacturing www drivemedical com ...

Page 7: ...trol box bottom at left side Plug actuator in control box bottom at middle Fit the adjusting handle REMARKS Please always check the mast is fully locked into position Drive Medical Design and Manufacturing www drivemedical com ...

Page 8: ...endant g Unlock rear casters and transfer patient to and above commode or wheelchair Lock brakes of both lifter and commode or wheelchair h Press the button on the control handset to gradually lower the patient i During descent assist patient to attain correct sitting posture j For transferring to wheelchair when patient is seated push down on boom to slacken hanging strips of sling Patient can re...

Page 9: ...e controller will give beep warning At this moment you should charge the battery immediately Please note that a lifted patient cannot be lowered down when battery is out of power 4 Push the Emergency red button if the control unit system is out of control 5 QUICK RELEASE system push pull enables stepless retraction of the actuator under load Mechanical emergency lowering Refer to Picture A Picture...

Page 10: ...e sure base adjustment mechanism is operating easily e Double check to ensure the U bracket at the end of the boom and the S hook on the hanging bar are secured tightly f Work the Linak Actuator to ensure that the battery still has enough power When battery is 50 below full capacity it will give beep warning and need to re charge immediately g Before initial use place a drop of oil on the followin...

Page 11: ...Drive Medical Design and Manufacturing www drivemedical com Drive Medical Design Manufacturing 99 Seaview Boulevard Port Washington NY 11050 Phone 516 998 4600 Fax 516 998 4601 www drivemedical com ...

Reviews: