background image

15

REPLACEMENT  PARTS

Table 15-1: Space Distribution Unit (SDU-E)

Table 15-2: VAPORMIST

®

 subpanel with SDU-E

12 13

*Specify model size when ordering

11

7 8

3

5

1

4

14

10

6

13

12

8

9

2

9

6

6

5

1

7

4

2

3

13

2

2

8

18

14

16 17

12

10

15

11

19

No.

Description

Qty.

Part No.

1

Cabinet base, VM99

1

330000-003

2

Blower, SDU99 external assembly

1

409540-003

3

Frame, SDU external

1

165542

4

Dispersion chamber, SDU99 w/ 1½" out

1*

160445-001

4

Dispersion chamber, SDU99 w/ 2" out

1*

160445-002

5

Switch, air flow

1

406190

6

Tubing, 3/8" OD x .060 clear vinyl

1

405722

7

Nut, 8-32 x 3/8"

2

700200-002

8

Star washer, 8-32

6

700200-003

9

Screw, self tapping 8-32 x 3/8"

4

700170-001

10

Screw, 8-32 x 1/2" panhead Phillips F

4

700170-001

11

Cage clip, 8-32

4

409593-001

12

Lock washer, 1/4"

6

700300-005

13

Nut, 1/4-20 hex

10

700300-016

14

Cap, black

4

409593-002

No.

Description

Qty.

Part No.

1

Subpanel, VM99 barrier

1

120801

2

Ground lug, L-35 10-14 GA CP-8

1

409250-017

2

Ground lug, L-70 6-8 GA CP-4

1

409250-018

3

Transformer,  600V

1

408896

3

Transformer, 120/240/480/208

1

408965-001

4

Channel, wire with cover

2

408999-003

5

Main board, VL-3

1

408490-001

6

Display board, VL-3 with enclosure

1

408490-002

7

Plug, 4-prong female

4

409585-008

8

3-pole, 3-phase, power block

1

408300-002

8

2-pole 1-phase, power block

1

408300-001

9

Fan, 24 Volt

1

408677-001

10

Power plug

1

409585-001

11

Terminal

8

408252-001

12

Terminal, ground

1

408252-010

13

Terminal, end plate

1

408252-005

14

Terminal, jumper

2

408252-008

15

Relay, 24V

1

407900-016

16

Relay socket

1

407900-011

17

Breaker 1-pole 1.6A 480V

2

406775-001

17

Breaker, 1-pole 1.5A 600V

2

406775-003

18

Contactor, 60A

1

407001-021

18

Contactor, 32A

1

407001-020

19

Transformer, 480V 300VA

1

408991

19

Transformer, 575V 300VA

1

408982

19

Transformer, 480V 500VA

1

408996-008

19

Transformer, 600V 500VA

1

408996-009

VMOM-0600.PDF   15

11/19/2009   9:59:11 AM

Summary of Contents for VAPORMIST

Page 1: ...AND SAVE THESE INSTRUCTIONS VAPORMIST and VAPORMIST DI ELECTRIC STEAM HUMIDIFIERS Installation Operation and Maintenance Manual For toll free technical support call 1 800 328 4447 cETL LISTED ETL LIS...

Page 2: ...s DRI STEEM Humidifier Company VAPORMIST and VAPORMIST DI humidifiers 3 Installation Locating and mounting the VAPORMIST humidifier 4 Examples of mounting the dispersion tube 4 Mounting dispersion tub...

Page 3: ...INCOLOY alloy sheathed immersion heaters Keyholes for wall mounting Water fill NPT DN8 female 1 DN40 or 2 DN50 flexible vapor hose connects to dispersion tube in duct Condensate return line Duct Elect...

Page 4: ...in duct Vapor hose and dispersion tube s should be pitched back to the humidifier with a minimum gradual slope of 2 per foot 15 A single dispersion tube cannot be used with VM 30 or VM 34 Figure 4 2...

Page 5: ...ondensate drain tubing is not provided by DRI STEEM A minimum pitch of 2 ft 15 back to the humidifier must be maintained in the dispersion tube when there is no separate condensate drain Condensate dr...

Page 6: ...drain pipes into a single drain line may result in the backflow of drain water into the humidifier cabinet causing the unit to malfunction All wiring must be in accordance with all governing codes and...

Page 7: ...6 mm 2 25 57 mm Top view Back of enclosure Front of enclosure OM 282 1 Power wire knockout Humidistat or SDU knockouts 24 19 614mm 3 4 NPT DN20 tankdrain 3 4 NPT DN20 framedrain Model number Steam cap...

Page 8: ...re it disappears it could collect and drip as water The greater the space relative humidity the more the fog will rise throw and spread before disappearing The dis tances the fog travels before it dis...

Page 9: ...SDU E mechanical detail OM 54 1 2 25 57 mm Steam inlet Steam outlet If the SDU E or SDU I is immediately above the VAPORMIST disconnect both hose clamps on the steam hose grip the hose and rotate it t...

Page 10: ...that proper grounding and an approved earth groundareprovided 2 Confirm that the control signal being connected to the VAPOR LOGIC3 system is compatible with the VAPOR LOGIC3 program Identify the VAP...

Page 11: ...the electrical panel cover or heater terminal cover until electrical power is disconnected Safety first If the VAPORMIST has an SDU mounted directly above it the SDU cover must be removed before remov...

Page 12: ...tank to drain completely Disconnect the fill line at the fill fitting Disconnect the electrical plugs between the tank components and the back of the electrical panel includes power plug low water sw...

Page 13: ...control voltage across the fill valve output Humidifier does not stop filling Lack of tank to probe electrical continuity Water conductivity must be 100 micromhos cm 2 gr gal or 34 2 mg liter Add sal...

Page 14: ...oning float switch Check to make sure that float moves freely on stem Plugged fill valve Check fill valve inlet Humidifier does not stop filling Open drain valve Obstruction in drain valve will not al...

Page 15: ...ack 4 409593 002 No Description Qty Part No 1 Subpanel VM99 barrier 1 120801 2 Ground lug L 35 10 14 GA CP 8 1 409250 017 2 Ground lug L 70 6 8 GA CP 4 1 409250 018 3 Transformer 600V 1 408896 3 Trans...

Page 16: ...on pages 17 and 18 VM Model VMDI Model 3 1 2 19 25 6 7 34 8 34 22 24 28 20 15 16 11 33 32 31 10 18 25 9 4 5 13 35 36 12 15 11 27 20 16 17 29 30 23 21 26 25 37 3 4 NPT frame drain male Tank drain Hole...

Page 17: ...05390 006 5 Hose cuff 2 ID VM 21 34 1 305391 006 6 Cover tank 1 7 Heater element 8 Probe assembly cord and plug 1 406050 005 9 Probe assembly gasket 1 309750 004 10 Probe assembly VM 2 4 1 406270 10 P...

Page 18: ...pter VM 6 16 1 160224 041 22 Fill adapter VM 21 34 1 160224 052 23 Panel insulation 1 309845 003 24 Sensor temperature 1 405760 25 Screw Phillips head 8 32 x 8 700170 007 26 Frame assembly chassis 1 1...

Page 19: ...mer 600V 1 408986 3 Transformer 120 208 240 480 1 408965 001 4 Channel wire with cover 2 408999 003 5 Main board VL 3 1 408490 001 6 Keypad board VL 3 1 408490 002 7 Plug 4 prong female 4 409585 008 8...

Page 20: ...irect associated with the installation removal or reinstallation of any defective product DRI STEEM s limited warranty shall not be effective or actionable unless there is compliance with all installa...

Reviews: