background image

11

10

If you live in a humid environment and have problems with mold or algae 

(the parts may feel “slimy”), simply soak all of the plastic parts (excluding 

the pump) in a diluted bleach solution for about 10 minutes after regular 

cleaning. We recommend using a solution that is 10% bleach and 90% 

water. Pour some of the bleach solution down into the pump’s cavity as 

well. You must be sure to rinse all the parts very thoroughly to remove all 

the chlorine. The best way to rinse out the pump’s cavity is to hold it under 

a weak stream of warm water. This is also an excellent way to disinfect 

the fountain. 

If you have “hard water” where you live, you may start to see white mineral 

deposits on or down inside the pump. This may eventually prevent the 

impeller from turning properly. To avoid having to replace the pump:

A.  Clean the pump more frequently; or

B.  Clean with regular white vinegar and let the vinegar soak for 

several  minutes down inside the pump’s cavity; or

C.  Use bottled water.

FOUNTAIN & YOUR ENVIRONMENT

MANUFACTURER’S SAFETY 

INSTRUCTIONS

The electrical use of this appliance 

is 3 watts.

Close supervision is necessary when 

any appliance is used by or near 

children.

Always unplug any appliance when 

not in use, before putting on or taking 

off parts, and before cleaning.  Never 

yank on a cord to remove from the 

outlet.

Do not use appliance for anything 

other than intended use. The use of 

attachments not recommended or 

sold by the manufacturer may cause 

an unsafe condition. Do not modify 

the unit.

Do not install or store appliance 

where it will be exposed to weather or 

temperatures below freezing.

Read and observe all important 

notices on the appliance.

Do not attempt repairs on the pump 

yourself. 

If the plug of this device gets wet, 

turn off the electricity to that outlet. 

Do not  attempt to unplug.

To avoid the possibility of the plug or 

outlet getting wet, the outlet should 

always be above the level of the 

fountain.

Examine this appliance after 

installation. Do not plug in if there 

is water on the cord or plug.

Do not operate any appliance if it 

has a damaged cord or plug, or 

if it is malfunctioning or has been 

damaged.

If an extension cord is necessary, 

a cord with a proper rating should 

be used.

FOR INDOOR USE ONLY!

1)  The fountain is meant to run continuously (always plugged into electricity), 

as long as the water level is maintained and the fountain is cleaned 

regularly. Be sure to check the fountain regularly to help prevent damage 

to the pump, as the water may get consumed or evaporate causing the 

pump to run dry.

2)  Do not allow pets or children to chew on or swallow any parts. If you are 

concerned about the power cord, purchase a cord conduit (a hard plastic 

protector) at any hardware store.

3)  Some animals have been known to be sensitive to plastic. If your animal 

shows signs of an allergic reaction to the plastic, please discontinue use 

until you have consulted with your veterinarian.

4) 

Standard Safety Precautions:

When being introduced to the Drinkwell

®

 Pet Fountain, your pet may 

be cautious of this new and unusual object. After beginning operation 

of your fountain, simply allow your pet to adjust at his or her own pace. 

Some pets may take several days or longer to begin use. 

Your pet may prefer that the fountain be placed away from their normal 

feeding area. Try plugging it in somewhere else, like a laundry room, a 

bathroom or another corner of the kitchen. 

Add ice cubes to the bowl for refreshing, ice-cold running water! 

TIPS ON USE

Summary of Contents for Ceramic Lotus Pet Fountain

Page 1: ...tions or has been dropped or damaged in any manner Call customer service immediately for further instructions For a portable appliance To reduce the risk of electrical shock do not place or store appliance where it can fall or be pulled into a tub or sink Always unplug any appliance when not in use before putting on or taking off parts and before cleaning Never pull on the cord to remove the adapt...

Page 2: ...in place by the clip on the tube connector See Fig 3b 4 Housing U S Patents No 5 799 609 and 5 842 437 5 Fig 1 Housing Cap Replace the housing by aligning the large gap at the bottom of the housing with the raised bump on the bottom of the main bowl The gap in the housing is shown in Fig 4a next page and the raised bump is circled in Fig 4b next page The housing should rest flat and stable on the ...

Page 3: ... lock on the housing See Fig 5 With these two items aligned press down on the cap while simultaneously turning it to the right this will secure the cap Fig 4b Fig 4a 7 8 9 10 11 12 Place the O ring over the housing See Fig 6 Next slide the upper dish onto the housing Rotate the upper dish until you are happy with how the spouts line up with the bottom bowl Adjust the flow of water by turning the h...

Page 4: ...ishwasher only the plastic and ceramic pieces If possible it is recommended that you turn down the heat of the water inside the dishwasher See the Pump Maintenance section of this manual for detailed instructions on how to clean your pump 7 8 Pump Impeller Stator Intake Plate Stator Pull Tab Fig 11a Fig 11b REPLACING THE FILTER FILTERS CHANGE EVERY 2 to 4 WEEKS 1 Filters should be changed every tw...

Page 5: ...ace the pump inside the filter so that the cord rests on top of the filter not beneath it Fig 17 Fig 16 6 With the pump and filter in place insert the Intake Tube into the opening at the top of the pump Move the Tube Connector up the shaft of the Cord Pass Thru Tube slightly to make room for the Intake Tube See Fig 18 7 With both tubes in place slide the Tube Connector back down the shaft so that ...

Page 6: ...nt notices on the appliance Do not attempt repairs on the pump yourself If the plug of this device gets wet turn off the electricity to that outlet Do not attempt to unplug To avoid the possibility of the plug or outlet getting wet the outlet should always be above the level of the fountain Examine this appliance after installation Do not plug in if there is water on the cord or plug Do not operat...