User Manual
RANGE HOOD | COMPACTA
76
10
7. INSTALLATION OF ASSEMBLY WITH
RECIRCULATION IN THE CABINET
IMPORTANT
: The charcoal filter must be installed in the filter version extractors. The two
outlet points of the extractor must be blocked with the air outlet covers (9).
1. As shown (fig.5), drill a 133 mm diameter hole in the cabinet, check the position of
the power outlet, and consider whether the power cord of the appliance reaches the
wall outlet.
2. Mark 4 points for the holes in the cabinet, respecting the indicated distances (fig.6).
Drill 4 6 mm diameter holes in the cabinet.
3. Push the extractor into the cabinet and insert the 4 screws (5) that operate from the
inside of the cabinet. Tighten the screws completely.
FASTENING CONDUCT
Caution to reduce the risk of fire, we use
only metal material.
1. Glue a round tube 120 mm long in
the recessed area of the air outlet
adapter.
2. Secure the conduit with the two
screws that are already attached to
both sides of the air outlet adapter.
Make sure the conduit is securely
fastened.
CONNECTIONS
Exhaust system through air
CAUTION:
To reduce the risk of fire. Use metal conduits.
1. Decide where the line of ducts between the extractor and the outside goes.
2. Use a straight pipe section and allow the extractor to work as efficiently as possible.
3. Long tube runs, elbows, prevent proper operation of the extractor. Use as few of
them as possible. For larger ducts longer tubes can be used for best performance.
4. Attach a suitable length of 120 mm round tube to the air outlet adapter.