ERROR MESSAGES 

The table below shows error message that the system may detect. If the display shows an “ER” message, first unplug the 
unit and then plug it back in. This may re-set the electronics, and if so, no further action is required. If the error message 
reappears, try the solution under “Explanation.” If this still does not fix the problem, contact Dri-Eaz Service Department 
on +44 (0)1908-611-211. 

 

C O N T R O L   P A N E L  

M E S S A G E  

E X P L A N A T I O N  

ER1 CONTACT SERVICE 
CENTER  

Check AC power for inadequate voltage. The electronic 
control panel may require replacement. Contact service. 

ER2 CONTACT SERVICE 
CENTER  

The electronic control panel may require replacement. 
Contact service. 

ER3 CONTACT SERVICE 
CENTER  

Check defrost sensor for proper connection. Check sensor 
cable for damage. Sensor assembly may need 
replacement. Contact service. 

ER4 

√ DEFROST SENSOR 

CONNECT 
 

– or – 

ER4 

√ OUTLET SENSOR 

CONNECT 

Check defrost sensor for proper connection. Check sensor 
cable for damage. Sensor assembly may need 
replacement. Contact service. 

ER5 

√ 

SENSOR CONNECT 

ON BOARD 

Check temp/RH sensor connections. 

ER6 CONTACT  
SERVICE CENTER 

The high voltage board may need replacing. Contact 
service. 

ER7 INVALID 
MODEL SETTING 

Incorrect DIP switch settings or firmware version for that 
specific model. Contact service.  

ER8 BUTTON STUCK 

√ 

ALL BUTTONS 

Press each membrane button and check for proper 
operation. Membrane overlay may require replacement. 
Contact service. 

ER9 PUMP BLOCKED 

√ 

CHECK PUMP & HOSE 

Check for obstructions in drain hose. Check the pump. 

 

Summary of Contents for LGR1800

Page 1: ...h using maintaining and servicing your equipment and provides us with your contact information in case we need to communicate important safety information concerning your Dri Eaz product If you determ...

Page 2: ...meter to gauge temperature For improved accuracy take temperature readings in in the center of the room away from the airflow of the dehumidifier Dri Eaz dehumidifiers warm the air as they remove mois...

Page 3: ...either from a power interruption or from thermal overload protection let the unit rest for five minutes before restarting Otherwise it might shut off again Turn the unit on The control panel on the LG...

Page 4: ...ted JOB HOURS RESET Press to reset hours to zero NOTE When in Humidistat mode the unit will display HUMIDISTAT on the top line during normal operation rather than JOB HOURS LIFE HOURS 00 HRS Shows tot...

Page 5: ...aminants Monthly Check coils Dirty coils can cause the unit to overheat Clean when visibly dirty See Fig E 1 Unplug unit 2 Remove housing locate coils and allow coils to dry if wet 3 Vacuum coils surf...

Page 6: ...panel may require replacement Contact service ER3 CONTACT SERVICE CENTER Check defrost sensor for proper connection Check sensor cable for damage Sensor assembly may need replacement Contact service...

Page 7: ...gh unit is restricted Check humidity with hygrometer Increase room temperature Check filter and coils clean as necessary If the problem you are experiencing is not listed here call Dri Eaz Service Dep...

Page 8: ...ucts PURCHASE Purchase date ________________________ Serial number ________________________ Distributor ________________________ Tel _________________________ MAINTENANCE D A T E S E R V I C E P E R F...

Reviews: