OPERATING YOUR DEHUMIDIFIER 

Set unit upright 

Always operate the dehumidifier in an upright position. If 
the unit has been stored or transported in a horizontal 
position, set it upright (in a vertical position) for at least 
30 minutes before operating it. This will allow for any 
compressor oil that has flowed into the refrigerant coils 
to return to the compressor and allow the dehumidifier to 
function properly. 

Set up drain hose 

The LGR1800 pump connects to a plastic drainage 
hose. The hose can be stored on the hose wrap, located 
on the back of the unit (see Fig. A). You can release the 
hose by rotating the top reel of the hose wrap down; 
simply pull outward until you’re able to rotate it (see Fig. 
C). Rotate the tab to the right or left until it is pointing 
straight down. This feature makes it easy to take off the 
entire hose quickly. Place the unattached hose end in a 
sink, drain, bucket –even outside; anywhere that water 
can drain out safely.  

NOTE: 

Uncoil and straighten the entire drain hose. 

Do not leave any of part of the hose coiled on the 
unit and do not place the end of the hose higher 
than 4.5 m (15 ft.) above the top of the unit. Also 
check for kinks, or obstructions that would restrict 
the flow of water. Failure to do so may cause a water 
backup in the pump resulting in leakage.

 

Plug in electrical cord 

The electrical cord is wrapped around the top of the unit. 
The LGR1800 will operate on any standard 230-volt 
Residual Current Device (RCD) protected outlet.  
 
If the unit experiences a loss of power, either from a 
power interruption or from thermal overload protection, 

let the unit rest for five minutes before restarting. 
Otherwise it might shut off again. 

Turn the unit on 

The control panel on the LGR1800 has a display and a 
touchpad with four keys. Press the 

 ON/OFF to turn 

the unit on.  

How to use the control panel 

The control panel on the LGR1800 has a display and a 
touchpad with four keys.  
 

 

ON/OFF

. Press the ON/OFF key to turn the unit on or 

off. When the machine turns on, the display normally 
reads PLEASE WAIT COMP. DELAY and performs a 
numeral count down from a maximum of 60 seconds 
to 0. This delay allows time for refrigerant pressures to 
equalise for easier starting. If you don’t see a 
compressor delay countdown, a delay is not necessary 
and the machine will begin operation immediately. Once 
the unit completes the compressor delay, the display 
shows UNIT ON XX HRS and cycles between 
INLET TEMP XX°C and INLET RH XX%. 
 

 

DISPLAY MENU

. Press the DISPLAY MENU key to 

cycle through the display of additional dehumidifier 
conditions and User Settings. To return to the main 
menu, press the ON/OFF button once. 
 

 

MENU SELECTION

. Press the MENU SELECTION 

key to change the values on the "User Defined" settings. 
The MENU SELECTON key acts as the UP key for 
adjusting the setpoint for Humidistat mode operation. 
See User Settings Menu (below) for details. 
 

 PURGE

. Press the PURGE key to manually empty 

water from the condensate pump reservoir. NOTICE: 
Always press the purge key prior to moving the unit. 
During normal operation, the pump purges automatically 
every six minutes, or whenever the reservoir is full. The 

Moulded cord storage.  

Air filter access 
door. Lift handle 
to release. 

Process (dehumidified) air 
outlet. May be used with 
standard 300 mm (12 in.) 
rigid or layflat ducting. 

Humid air inlet 
(both sides).  

Control panel 

FIG. D: FRONT

 

Summary of Contents for LGR1800

Page 1: ...h using maintaining and servicing your equipment and provides us with your contact information in case we need to communicate important safety information concerning your Dri Eaz product If you determ...

Page 2: ...meter to gauge temperature For improved accuracy take temperature readings in in the center of the room away from the airflow of the dehumidifier Dri Eaz dehumidifiers warm the air as they remove mois...

Page 3: ...either from a power interruption or from thermal overload protection let the unit rest for five minutes before restarting Otherwise it might shut off again Turn the unit on The control panel on the LG...

Page 4: ...ted JOB HOURS RESET Press to reset hours to zero NOTE When in Humidistat mode the unit will display HUMIDISTAT on the top line during normal operation rather than JOB HOURS LIFE HOURS 00 HRS Shows tot...

Page 5: ...aminants Monthly Check coils Dirty coils can cause the unit to overheat Clean when visibly dirty See Fig E 1 Unplug unit 2 Remove housing locate coils and allow coils to dry if wet 3 Vacuum coils surf...

Page 6: ...panel may require replacement Contact service ER3 CONTACT SERVICE CENTER Check defrost sensor for proper connection Check sensor cable for damage Sensor assembly may need replacement Contact service...

Page 7: ...gh unit is restricted Check humidity with hygrometer Increase room temperature Check filter and coils clean as necessary If the problem you are experiencing is not listed here call Dri Eaz Service Dep...

Page 8: ...ucts PURCHASE Purchase date ________________________ Serial number ________________________ Distributor ________________________ Tel _________________________ MAINTENANCE D A T E S E R V I C E P E R F...

Reviews: