TROUBLESHOOTING
F A U L T
C A U S E
S O L U T I O N
Unit does not
operate
No power to machine.
Unit not switched on.
Plug in unit; check power at outlet and at base of unit.
Switch unit on.
Blower wheel
not turning
Obstructed blower.
Remove duct ring and grill.
Remove obstruction.
Replace duct ring and grill.
Unit operating,
but room not dry
Not enough time to dry.
Poor air movement in room.
Excessive moist air infiltration.
Allow more time for drying.
Increase air movement with air movers.
Reduce infiltration.
Unit
continuously in
defrost mode
Room temperature too low
Increase room temperature.
Pump does not
function
Stuck float valve
Clean float valve shaft.
Unit collects too
little water
Room air is dry.
Room temperature is too low.
Check humidity with hygrometer.
Increase room temperature.
Check filter and coils; clean as necessary.
If the problem you are experiencing is not listed here, call your local distributor or contact the Dri-Eaz Service
Department toll-free at 800-932-3030.
SPECIFICATIONS
Model
DRIZAIR 1200 F203
Type
Standard refrigerant
Refrigerant
R-410A
Use weight
80 lbs. | 36 kg
Dimensions
(H × D × W)
32 × 20 × 19.5 in.
83 × 50 × 50 cm
Power
6.8 amps, 110 volts
Water removal AHAM
(80°F/60% RH)
54 pts. | 25.5 liters / day
Water removal max.
(90°F/90% RH)
105 pts. | 49.7 liters / day
Max process air
202 CFM | 343 CMH
Operating range
33°–100°F | 1°–38°C
Air filter
3M HAF filter (part no. F368)
Power cord
25 ft. | 7.6 m
Construction
Rotomolded polyethylene housing
Safety
CE
Specifications are subject to change without notice. Some
values may be approximate.
Warranty information is available at
CONTACT
Dri-Eaz Products, Inc.
15180 Josh Wilson Rd.
Burlington, WA 98233
800-932-3030
07-01502B 2014-04 Warranty 07-00427