background image

Owner’s Manual 

Dri-Eaz 1200 110V/50Hz Portable Dehumidifier 

DRI-EAZ PRODUCTS, INC.  

15180 Josh Wilson Road, Burlington, WA 98233 

Phone: 800-932-3030

 

Fax: 360-757-7950

 

www.dri

-

eaz.com

  

Dri-Eaz 1200 dehumidifiers reduce humidity in enclosed structural environments by 
removing water vapor from the air. The 1200 is engineered to be rugged, durable and highly 
portable, making them ideally suited for water damage restoration, structural drying, 
construction, and other applications requiring temporary, high-performance 
dehumidification.  

 

R E A D   A N D   S A V E   T H E S E   I N S T R U C T I O N S

 

SAFETY INSTRUCTIONS 

 

 

 

 

 

 

WARNING! Electric shock hazard, rotating fan, hot 
surface hazards. Unplug unit before opening cover 
for cleaning or servicing. Unit must be grounded. 

  Inspect the power cord before use. If cord is 

damaged, do not use. Always grasp the plug (not 
the cord) to unplug. 

  Insert three-prong plug on power cord into a 

matching electrically grounded outlet. Do not use 
adapter. Never cut off third prong. Do not use an 
extension cord.  

  The unit must be operated on a 110V/50 Hz circuit 

protected by a Ground Fault Circuit Interrupter 
(GFCI) device.  

  Keep motor and wiring dry. 

  Do not attempt to repair the unit. For Authorized 

Service Centers, call Dri–Eaz at 800-932-3030. 

BEFORE YOU BEGIN 

Unpacking your unit 

Retain all packing material and boxes for possible 
equipment returns.  
 

Install the handle 

The 1200 is shipped without the handle attached. Install 
the handle using the four ¼-20 hex washer-head bolts 
supplied 

and a ⅜ in. driver or wrench. Make sure the 

bolts are firmly secured before using the unit.   

Warranty registration 

Visit 

warranty.drieaz.com

 to register your purchase. 

Registration allows us to better assist you with using, 
maintaining or servicing your equipment, as well as to 
contact you in case we have important safety information 
concerning your Dri-Eaz product. If you determine 
service is required, have your equipment model, serial 
number and original proof of purchase available and call 
your distributor for assistance with obtaining a return 
material authorization (RMA). 

 

INTRODUCTION 

Dehumidifiers reduce humidity in enclosed structural 
environments by removing water vapor from the air. With 
proper use, the 1200 can help dry carpet, carpet pad, 
floors, walls, building contents and more. Using 
dehumidifiers can also help prevent secondary damage 
caused by high humidity. For best results, use the 1200 
with Dri-Eaz TurboDryer® airmovers placed around the 
perimeter of the room to distribute heat energy and 
release moisture from wet surfaces into the air. 

How the 1200 dehumidifier works 

Dri-Eaz refrigerant dehumidifiers operate by pulling 
moist air in across a very cold evaporator coil. The 
moisture in the air condenses on the coil. In certain 
conditions, the machine operates in defrost mode, 
warming any frost accumulated on the evaporator coil 
back into water. The water collects in a tray and is 
pumped out through a hose.  
 
IMPORTANT: Before moving the unit, make sure there’s 
no water in the pump. See how to use the PURGE 
function under “How to use the control panel” on page 2.  

POSITIONING A DEHUMIDIFIER 

For best results, operate your dehumidifiers in an 
enclosed area, as this creates a drying chamber. Close 
all doors and windows that open to the outside to 

WARNING

 

07-01502B 2014-04 Warranty 07-00427 

Dri-Eaz Products, Inc.  

Summary of Contents for DrizAir 1200

Page 1: ...ore using the unit Warranty registration Visit warranty drieaz com to register your purchase Registration allows us to better assist you with using maintaining or servicing your equipment as well as t...

Page 2: ...to a plastic drainage hose that is wrapped around the air outlet located at the back of the unit This hose is equipped with a quick connect fitting for quick attachment to the provided 40 ft drain hos...

Page 3: ...ess the PURGE key to empty water from the pump reservoir During normal operation the pump purges automatically every six minutes or whenever the reservoir is full The display will read PUMP PURGING wi...

Page 4: ...k drain hose 1 Look for obstructions Disconnect and clear any debris present 2 Reattach gravity drain hose Annually Have the pump system inspected by the Dri Eaz Service Department 800 932 3030 or by...

Page 5: ...room temperature Check filter and coils clean as necessary If the problem you are experiencing is not listed here call your local distributor or contact the Dri Eaz Service Department toll free at 800...

Page 6: ...uptor del circuito de fallos de conexi n a tierra GFCI por sus siglas en ingl s Mantenga el motor y los cables secos No intente reparar la unidad Para conocer los Centros de Servicio T cnico Autorizad...

Page 7: ...g rese de colocarlo en el centro de la habitaci n alejado del flujo de aire del deshumidificador Si la temperatura alcanza niveles peligrosos m s de 90 F 32 C puede hacer que disminuya usando el siste...

Page 8: ...ar Una vez que desaparece la leyenda RETAR COMPRS aparece en la pantalla DESHUMIDIFICADOR PRENDIDO y se alternan los mensajes TOTAL DE HORAS HORAS DE TRABAJO y DESHUMIDIFICADOR PRENDIDO Vuelva a presi...

Page 9: ...e externa vaciarla con cuidado MANTENIMIENTO ADVERTENCIA PELIGRO DE DESCARGA EL CTRICA Desenchufe el deshumidificador 1200 antes de realizar cualquier tarea de mantenimiento Antes de cada uso Controle...

Page 10: ...2 Transp rtelo y almac nelo de manera segura para evitar cualquier impacto que da e las partes internas LEA Y GUARDE ESTAS INSTRUCCIONES MENSAJES DE ERROR El siguiente cuadro muestra los mensajes de e...

Page 11: ...metro Aumente la temperatura de la habitaci n Controle el filtro y los serpentines l mpielos si es necesario Si su problema no est incluido aqu llame al distribuidor de su zona o comun quese sin cargo...

Page 12: ...liste des centres d entretien agr s appelez Dri Eaz au 800 932 3030 AVANT DE COMMENCER D ballage de l appareil Conservez tout le mat riel d emballage et les cartons pour un renvoi ventuel Pose de la p...

Page 13: ...CVC chauffage et climatisation pour la faire baisser R glez le 27 C 80 F et continuez de faire fonctionner l appareil S il n y a pas de syst me CVC appelez Dri Eaz au 800 932 3030 et un sp cialiste vo...

Page 14: ...ICATEUR EN MARCHE ou ARR T HEURES TOTALES ou HEURES TRAVAIL lors du cycle Appuyez une nouvelle fois sur le bouton AFFICHAGE pour red marrer le cycle Changement de la langue de l affichage ATTENTION En...

Page 15: ...centre de services le plus proche Inspectez et videz le filtre selon les besoins Conservez toujours un filtre propre dans l appareil afin de prot ger les composants internes contre l accumulation de...

Page 16: ...iter tout impact dommageable sur les pi ces internes AND SAVE THESE INSTR MESSAGES D ERREURS Le tableau ci dessous indique des messages d erreurs que le syst me pourrait d tecter Si l cran affiche un...

Page 17: ...e L air de la pi ce est sec La temp rature de la pi ce est trop basse V rifiez l humidit avec un hygrom tre Augmentez la temp rature de la pi ce Inspectez le filtre et les serpentins nettoyez selon le...

Page 18: ...___ Distributor Distribuidor Distributeur ____________________________ Tel Tel T l ________________________ MAINTENANCE MANTENIMIENTO MAINTENANCE D A T E F E C H A D A T E S E R V I C E P E R F O R M...