ERROR MESSAGES 

If the control system detects an error, it will produce an error (“ER”) message. If this occurs, first unplug the unit and then 
plug it back in. This will usually reset the electronics, and the unit will begin operating normally. If the error message reap-
pears, refer to the explanations and solutions shown below. If these solutions do not fix the problem, contact your local 
authorized service centre.  

 
NOTE: The message “POWER FAILURE” is not a system error. When this message is displayed, it indicates that 
power to unit was interrupted and then restored. To clear the message, press the 

 MENU SELECTION key. 

 

C O N T R O L   P A N E L  

M E S S A G E

 

E X P L A N A T I O N   A N D   S O L U T I O N

 

ER1 CONTACT SERVICE 

CENTER 

Indicates a serious internal problem. The electronic control panel may require replace-
ment. Contact service. 
Air Inlet temperature set point for cycling dehumidifier to control temperature. 
Check AC power for low voltage. 

ER2 CONTACT SERVICE 

CENTER 

Control panel error. The electronic control panel may require replacement. If error per-
sists, contact service. 

ER3 CHECK  

ROTOR MOTOR 

React Temp minus Inlet Temp difference too high indicates rotor stopping 

– belt or 

drive motor issue. Check belt tension, belt failure, rotor cleats, and motor operation. 

ER4 CHECK  

AIRFLOW 

Heater amps too low indicates fan issue and/or inlet airflow restriction. Clear any ob-
structions from inlet, clean inlet filter and/or check fan operation. 

ER5 REACT  

SENSOR CONNECT 

 or 

ER5 PROCESS  

SENSOR CONNECT 

Temp sensor is open, missing, or shorted. Check that temp sensors are installed cor-
rectly on control panel. If error persists, contact service. 

ER6 SENSOR  

CONNECTION ON BD 

Inlet Temp/RH sensor is open, missing, or shorted. Check that inlet temp/RH sensor is 
installed correctly on control panel and inlet shroud. If error persists, contact service. 

ER7 CONTACT  

SERVICE CENTER 

Current sensor failure. If error persists, contact service. 

ER8 INVALID 

MODEL SETTING 

Incorrect or unsupported DIP switch settings. Contact your local distributor service de-
partment for correct DIP switch settings. 

ER9 BUTTON STUCK  

ALL BUTTONS 

Key is stuck or has been held down too long. Contact service,  

ER10 WIRELESS 

CONNECTION ON BD 

Wireless board has failed, Board is missing, shorted or has fallen off the control panel. 
Reinstall wireless board to clear error. Contact service. 

 

Summary of Contents for DriTec 4000i

Page 1: ...protected by a Residual Current Device RCD device Keep motor and wiring dry Always unplug unit before cleaning or servic ing Do not attempt to repair the unit For service contact your local distribut...

Page 2: ...el display will briefly cycle through a series of readouts This is part of the unit s self diagnosis proce dure and no user intervention is required Ducting Setup NOTICE For indoor use only Do not exp...

Page 3: ...ENU SELECTION UP KEY Change system settings The MENU SELECTION key acts as the UP key for cycling through the setpoints WATER REMOVAL Press and release to show a calculated amount of water removal in...

Page 4: ...ange the setting JOB HOURS RESET JOB HOURS 00 0 Press to reset to 0 INLET OUTLET 000 00 000 00 For information only REACT 000 00 For information only HEATER1CURRENT 00 A For information only HUMIDISTA...

Page 5: ...49 130B MANUAL DRITEC 4000i 230V AU 5 Legend Brands Inc Fig C Ducting Options...

Page 6: ...ICE Electric shock hazard Unplug unit before removing side panels NOTICE The unit is fitted with sensitive electronic sensors Protect the sensors and their lead wires from damage and do not expose the...

Page 7: ...er removal PERFORMANCE XXX LITRES 24H Displays calculated water removal in units indicated per day SYSTEM MESSAGES The Control Panel will display the following messages based on system performance and...

Page 8: ...If error per sists contact service ER3 CHECK ROTOR MOTOR React Temp minus Inlet Temp difference too high indicates rotor stopping belt or drive motor issue Check belt tension belt failure rotor cleat...

Page 9: ...irm humidity level with hygrometer Decrease temperature of intake air Decrease humidity of intake air Check filter Clean or replace as necessary If the problem you are experiencing is not listed here...

Reviews: