49-130B MANUAL, DRITEC 4000i 230V AU 

Legend Brands, Inc. 

 

 
 

 

CONTROL PANEL 

 

Press the 

 

ON/OFF to turn the unit on. 

 

 

ON/OFF

  

When the machine is turned on, the display normally reads PLEASE WAIT 
WARMING UP. Once the unit completes the warm-up procedure, the display 
shows UNIT ON XXX HRS and cycles between INLET XXX°C and IN-
LET XX%. 

 

DISPLAY MENU

  

Cycles through the display of additional dehumidifier conditions and User Set-
tings. To return to the main menu, press the ON/OFF key once.

 

 MENU SELECTION / 
UP KEY  

Change system settings. The MENU SELECTION key acts as the “UP” key for 
cycling through the setpoints.

 

 

WATER REMOVAL 

Press and release to show a calculated amount of water removal in pints/day. 
The unit will display PLEASE WAIT CALCULATING for a moment and then 
WATER REMOVAL XXX PINTS/24H. The display will automatically return to 
the “Unit On” display after a few seconds. NOTE: For greatest accuracy, allow 
the unit to operate for at least 5 minutes before performing this operation.  

NOTICE 

Condensation  may  collect  in  the  reactivation  duct  during  opera-
tion. Do not allow water to run back into the unit. This could cause 
a shock hazard or damage to the unit. 

Summary of Contents for DriTec 4000i

Page 1: ...protected by a Residual Current Device RCD device Keep motor and wiring dry Always unplug unit before cleaning or servic ing Do not attempt to repair the unit For service contact your local distribut...

Page 2: ...el display will briefly cycle through a series of readouts This is part of the unit s self diagnosis proce dure and no user intervention is required Ducting Setup NOTICE For indoor use only Do not exp...

Page 3: ...ENU SELECTION UP KEY Change system settings The MENU SELECTION key acts as the UP key for cycling through the setpoints WATER REMOVAL Press and release to show a calculated amount of water removal in...

Page 4: ...ange the setting JOB HOURS RESET JOB HOURS 00 0 Press to reset to 0 INLET OUTLET 000 00 000 00 For information only REACT 000 00 For information only HEATER1CURRENT 00 A For information only HUMIDISTA...

Page 5: ...49 130B MANUAL DRITEC 4000i 230V AU 5 Legend Brands Inc Fig C Ducting Options...

Page 6: ...ICE Electric shock hazard Unplug unit before removing side panels NOTICE The unit is fitted with sensitive electronic sensors Protect the sensors and their lead wires from damage and do not expose the...

Page 7: ...er removal PERFORMANCE XXX LITRES 24H Displays calculated water removal in units indicated per day SYSTEM MESSAGES The Control Panel will display the following messages based on system performance and...

Page 8: ...If error per sists contact service ER3 CHECK ROTOR MOTOR React Temp minus Inlet Temp difference too high indicates rotor stopping belt or drive motor issue Check belt tension belt failure rotor cleat...

Page 9: ...irm humidity level with hygrometer Decrease temperature of intake air Decrease humidity of intake air Check filter Clean or replace as necessary If the problem you are experiencing is not listed here...