access all interior spaces, the cabinets may need to be 
removed.  

NOTICE:

 Do not use the DriForce to extract liquid water or 

debris of any kind. This may damage the unit and void the 
warranty. 

DriForce Blower Setup 

The DriForce Blower is equipped with a blower outlet, a 
vacuum inlet, a power switch and a power cord. Plug in unit 
to an appropriate grounded 115V outlet rated for 15 amps.  

Attach vacuum hoses to the vacuum inlet and/or blower 
outlet.  

Set the DriForce blower out of high traffic areas to minimize 
a trip-and-fall hazard from the blower and the ADS. 

NOTE: The muffler/filter supplied with the DriForce should 
only be installed when using the DriForce in the Air Injec-
tion (Blower) mode, described under Phase 2 below. Do 
not use the muffler-filter when using with the DriForce in 
the air extraction mode (Phase 1). The filter is not intended 
to be used on the inlet (vacuum) side of the DriForce.  

Switch power on and off with the toggle switch, found in the 
base of the unit.  

Air Drying System (ADS) Setup 

Manifold configuration

 

Next, determine the number of manifolds needed for the 
job. The following setup will deliver 25 to 30 air exchanges 
per hour in each cavity, which is effective for most situa-
tions. Use a formula of one manifold (each manifold has 12 
injectors) for each 14 feet of interior 2 × 4 framed wall. For 
2 × 6 exterior framed walls, common walls in apartments 
and condos, double-sheeted fire walls, and dense or water-
resistant covered walls, use a formula of one manifold (12 
injectors) for each 7 feet of wall.  

After determining the number and length of hose assem-
blies and manifolds, set up the ADS system. Pre-
assembling the manifolds, tubing and injectors will save 
considerable time.  

Supply tube configuration

 

Two 200 ft. (60 m) lengths of 

of 

⅜ in. (0.375 mm) ID air supply 

tubing

are provided. This tubing can be cut to length with a 

pair of sturdy scissors or a utility knife. We recommend the 
cutting following tubing lengths to create a setup suitable 
for most standard wall-drying jobs:  

1. Set up THREE manifolds with the following lengths 
of tubing: 

Manifold 

no. 

Tubing 

quantity 

Tubing 

length 

Tubing locations  

on manifold outlets 

4 ft. 

1.2 m 

Outlets 1, 2, 11  
and 12 

3½ ft. 

1 m 

Outlets 3, 4, 9 and 10 

1 ft. 

30 cm 

Outlets 5, 6, 7 and 8 

 

2. Set up the remaining FIVE manifolds with the follow-
ing lengths of tubing: 

Manifold 

no. 

Tubing 

quantity 

Tubing 
Length 

Tubing locations  

on manifold outlets 

7½ ft. 
2.3 m 

Outlets 1 and 12 

6½ ft. 
2.0 m 

Outlets 2 and 11 

5½ ft. 
1.7 m 

Outlets 3 and 10 

4½ ft. 
1.4 m 

Outlets 4 and 9 

2½ ft. 
0.8 m 

Outlets 5 and 8 

1 ft. 

30 cm 

Outlets 6 and 7 

 

To install the tubing, slide the one end of the tubing over 
the manifold outlet nipple and insert an injector in the other 
end.  

Tightly seal off the last manifold on each run of ADS with 
an end-cap plug. Now place the injectors into the holes you 
have drilled or punched in the wall, cabinet or other as-
sembly.  

Ensure that all T-fittings, hose cuffs, manifolds, supply 
lines, and injectors are properly installed. Attach the ADS to 
the DriForce. Plug in the DriForce and switch it on briefly, 
checking all connections for air leakage. If needed, use a 
hose clamp to seal off any air leakage where the vinyl 
products connect up to hose barbs, etc. 

Drying Procedure 

Phase 1: Air Extraction (Vacuum) Drying 

Attach the ADS to the vacuum inlet of the DriForce 
blower unit and switch unit on.  

 

Diagram shows two inline ADS lines (left), and two double-ADS 
lines running from a T-fitting. It also shows tubing layouts for 
one or two injectors into each wall cavity. 

07-00274H F211-115V 

Dri-Eaz Products, Inc. 

Summary of Contents for DriForce InterAir F211-115V

Page 1: ...ead to electrical or fire hazards If power cord is damaged it must be replaced by a cord of the same type and amperage rating WARNING Do not touch grills when unit is operating NOTICE Keep motor dry For indoor use only NOTICE Unplug when not in use or when moving unit WARNING Do not allow children to play with or around the unit Be sure the unit is inaccessible to children when not attended NOTICE...

Page 2: ...s immedi ately above the top of baseboard and proceeding to dry with the baseboards in place This a necessary procedure where there is a desire to save a wall with a tiled wall base when value is added by avoiding the detachment of wall baseboards Making air access holes Punch holes with a carpet awl or use a drill with a 3 16 in bit Create at least one hole between each set of studs and about 2 i...

Page 3: ...ble time Supply tube configuration Two 200 ft 60 m lengths of of in 0 375 mm ID air supply tubingare provided This tubing can be cut to length with a pair of sturdy scissors or a utility knife We recommend the cutting following tubing lengths to create a setup suitable for most standard wall drying jobs 1 Set up THREE manifolds with the following lengths of tubing Manifold no Tubing quantity Tubin...

Page 4: ...e DriForce Position the dry air outlet of a dehumidifier near the DriForce air inlet or duct the dehumidifier outlet toward the DriForce inlet Desiccant dehumidifiers are especially useful for this purpose as the extremely dry air they produce can accelerate the dry ing of dense materials and assemblies NOTICE Do NOT tape or seal the dehumidifier ducting to the DriForce inlet as this could unbalan...

Page 5: ...léctricos o de incendio Si el cable está dañado debe ser sustituido por uno del mismo tipo y amperaje ADVERTENCIA No toque las parrillas cuando la unidad esté en funcionamiento AVISO Mantener seco el motor Sólo para uso interior AVISO Desenchufar cuando no esté en uso o cuando esté desplazando la unidad ADVERTENCIA No permita que los niños jueguen con o cerca de la unidad Asegúrese de que la unida...

Page 6: ...el zócalo para luego saber dónde instalarlo También se puede tener éxito haciendo las perforaciones en la pared inmediatamente por encima de la parte superior del zócalo para luego secarla con éstos sin ser retirados Éste procedimiento será necesario cuando se deba salvar una pared con un zócalo de azulejos cuando lo conveniente será evitar quitar de la pared estos zócalos Hacer agujeros de acceso...

Page 7: ...la de un colector cada colector tiene 12 inyectores por cada 14 pies de pared enmarcada de interior de 2 4 Para paredes enmarcadas exteriores de 2 6 muros comunes en apartamentos y condominios muros dobles antiflama y paredes firmes o recubiertas con materiales resistentes al agua usar una fórmula de un colector 12 inyectores para cada 7 pies de pared Después de determinar la cantidad y la longitu...

Page 8: ...n taladro para generar un pequeño orificio de ventilación justo por encima del punto más alto de humedad en la pared Esto permitirá un orificio de ventilación y ayudará a acelerar el proceso de secado al permitir un mayor flujo de aire a través de los materiales afectados Luego podrá ser fácilmente parcheado CONSEJO Para maximizar el secado en paredes revestidas con azulejos doble capa empapeladas...

Page 9: ...lastamiento 91 pies 28 m Tubería de 1 pulg 3 8 cm Pre cortada en 13 secciones de 7 pies 2 m Tamaño del orificio de inyector Menos de pulg 6 mm Tubería flexible 400 pies 122 m Tubería ID de pulg 0 375 mm Sistema de transporte guardado 2 bolsos de lona estilo maleta con manija y ruedas Modos de secado Por presión ya sea positiva o negativa Piezas incluidas 100 inyectores 8 colectores de 12 salidas c...

Page 10: ...ERTISSEMENT Ne faites jamais fonctionner une unité avec un câble d alimentation endommagé car cela peut entraîner un danger électrique ou un risque d incendie Si le câble d alimentation est endommagé il doit être rempla cé par un câble du même type et avec la même capacité en ampères AVERTISSEMENT Ne touchez pas les grilles lorsque l unité fonctionne ATTENTION Conservez le moteur au sec Pour un us...

Page 11: ... en insérant une spatule pour cloison sèche entre le levier et le mur Retirez les clous restants du mur ou par l arrière de la plinthe Inscrivez un chiffre sur le mur de la plinthe correspondante pour pouvoir la réinstaller en suite au bon endroit Toutefois pour réussir le sé chage il suffit de faire les pénétrations dans le mur immédiatement au dessus de la plinthe et de procéder au séchage avec ...

Page 12: ...spiration du DriForce Mettez sous hors tension avec l interrupteur à bascule qui se trouve à la base de l unité Préparation du système de séchage à l air ADS Configuration de collecteur Déterminez le nombre de collecteurs nécessaires pour la tâche La configuration suivante délivre 25 à 30 échanges d air par heure dans chaque cavité ce qui est efficace dans la majorité des cas Suivez le principe d ...

Page 13: ... d humidité à l intérieur de la cavité struc turale est égal à celui de l humidité dans la pièce il faut passer en mode d injection d air Le fait d injecter de l air ambiant dans les cavités structurales aide à poursuivre le processus de séchage C est particulièrement vrai si vous déshumidifiez l air ambiant ASTUCE Lorsque vous séchez des murs intérieurs utili sez un poinçon ou une perçeuse pour f...

Page 14: ...bes ADS indéformables 91 pi 28 m de tubes de diamètre de 1 po 3 8 cm Prédécoupé en treize sections de 7 pi 2 m Taille de trou d injection Moins de po 6 mm Tubes flexibles 400 pi 122 m de tubes de diamètre intérieur po 0 375 mm Matériel de transport rangement 2 sacs valises avec poignées et roulettes Modes de séchage Pression positive ou négative Pièces incluses 100 injecteurs 8 collecteurs 12 sort...

Reviews: