Dri-Eaz 125105 Owner'S Manual Download Page 3

124775

B

 HEPA 700

Legend Brands, Inc. 

Replacing the HEPA Primary Filter 

IMPORTANT:

 Performance is reduced when a non-Legend 

Brands primary filter is installed. 

For maximum filtration 

performance, use only Legend Brands filters. 

Do not clean 

and reuse the HEPA filter. Always replace the prefilter when 
replacing the HEPA filter. 

1.

Lay unit on its back and release the four (4) buckles. Lift
off the filter door.

2.

Remove the prefilter from the filter door and discard.

3.

Release the two locking tabs and lift out primary filter
element. Discard used filter.

4.

Replace HEPA primary filter, handling it with care, as filter
is easily damaged. Do not use a filter that is damaged.

5.

Place new prefilter(s) in filter door. Replace filter cover and
lock the four buckles securely.

Before each use 

Inspect the electrical cord for damage, and do not use the unit 
if you find any fraying, cuts, etc. Contact your local distributor 
for service.  

As Needed 

Clean exterior of housing and inside the filter compartment. 
Ensure housing is completely dry before reassembling. Do not 
apply liquids to control panel or to any electrical components. 

When using the HEPA 700 for remediation or in 
sensitive environments:  

Wear NIOSH-approved protective gear when changing
filters.

Change both filters after every remediation job.

Dispose of used filters according to local regulations.

Replace both the prefilter and HEPA filter to prevent
cross-contamination.

Clean the unit thoroughly (vacuum and damp wipe per
IICRC S520, 10.11) before removing it from the
containment area to avoid cross-contamination. Let the
unit dry before installing clean filters.

For parts and service contact your local distributor or 
Legend Brands: Live Chat - Info.legendbrands.com | 
Email: 

[email protected]

  

Filter Options 

Air Filtration Applications:

 

Prefilter(s)

 

Removes larger 

particulates 

– protects 

primary filter 

Specialty Prefilter

 

Carbon removes 
VOCs and odors 

Primary filter (HEPA)

 

Removes fine particulate 

down to .3 microns 

Water loss air filtration and mold
remediation*

Standard air scrubbing.

 For high particle

loads, such as construction or remodeling sites.

2-in. MERV 8 Pleated

Paper Filter 

#125026 (6 pk.) 

HEPA Filter 

#124966 (

1

 pk.)

#

145028 (8 pk.)

Odor control and air filtration.

 For removing

volatile organic compounds (VOCs), fumes from
paint and paint thinners, and many other
noxious odors, eg, from food, sewage, etc.

Smoke particulate and odor removal.

 Paper

prefilter and HEPA filter remove particulates
and carbon filter adsorbs odors.

1-in. MERV 8 Pleated

Paper Filter 

#125029 (12 pk.) 

1-in. Activated

Carbon Filter

#125027 (4 pk.) 

HEPA Filter 

#124966 (1 pk.)

 

#

145028 (8 pk.)

This equipment has been tested and found to comply with the 
limits for a Class B digital device, pursuant to part 15 of the 
FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential 
installation. This equipment generates, uses and can radiate 
radio frequency energy, and if not installed and used in 
accordance with the instructions, may cause harmful 
interference to radio communications. However, there is no 
guarantee that interference will not occur in a particular 
installation. If this equipment does cause harmful interference 
to radio or television reception, which can be determined by 
turning the equipment off and on, the user is encouraged to try 
to correct the interference by one or more of the following 
measures: 
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected
• Consult the dealer or an experienced radio/TV technician for
help”

SPECIFICATIONS 

Specifications are subject to change without notice. Some values may 
be approximate.

 

Model 

HEPA 700 (#125105) 

Airflow 

Variable to 700 CFM | 1189 CMH 

Static pressure 

3.0 in. (H

2

O) | 747 Pa 

Weight 

42.0 lbs. | 19.1 kg 

Dimensions 

(H × D × W) 

22.8 × 17.0 × 25.9 in. 
57.9 × 43.3 × 65.9 cm 

Amps/Power 

1.5 - 3.0 amps, 115v, 60 Hz, 350w 

Power cord 

25 ft. | 7.6 m 

Duct size 

14 in. | 35.6 cm 

Construction 

Injection-molded plastic housing 

Xactimate 

WTRNAFAN> 

Safety 

ETL listed to UL 507 and CSA C22.2 No. 113 

Specifications are subject to change without notice. Some values 
may be approximate.  

Summary of Contents for 125105

Page 1: ...pose you to chemicals including lead and phthalates known to the State of California to cause cancer birth defects or other reproductive harm For more information go to P65Warnings ca gov HEPA 700 APP...

Page 2: ...t 4 For additional setup instructions go to HEPA700 legendbrandsrestoration com Electrical Outlets You can connect up to eight 8 HEPA 700s on a 15 amp circuit on the lowest speed four 4 on the highest...

Page 3: ...old remediation Standard air scrubbing For high particle loads such as construction or remodeling sites 2 in MERV 8 Pleated Paper Filter 125026 6 pk HEPA Filter 124966 1 pk 145028 8 pk Odor control an...

Page 4: ...eur et les pi ces ou l ments lectriques l tat sec N utilisez pas l unit l ext rieur Pour usage l int rieur seulement Ne manipulez pas la prise lectrique ou l unit avec les mains mouill es Ne faites pa...

Page 5: ...logiciel et une surveillance et un contr le 24h 24 et 7j 7 pour assurer une filtration optimale de l air Conduits facultatifs L admission accepte des conduits armature de fil m tallique standard de 14...

Page 6: ...faces int rieures de l unit ou essuyez les l aide d un chiffon humide 5 Installez un filtre primaire neuf Assurez vous que les languettes se verrouillent en position Avant chaque utilisation Inspectez...

Page 7: ...uses autres odeurs nocives 1 po Filtre en papier pliss MERV 8 No 125029 paq de 12 1 po Filtre au charbon actif No 125027 paq de 4 HEPA Filtre en microfibres de verre No 124966 paq de 1 No 125028 paq d...

Page 8: ...todas las fuentes de alimentaci n de los aparatos de combusti n abiertos como chimeneas calderas hornos calentadores de agua y sistemas de climatizaci n para evitar el riesgo de que se produzcan humos...

Page 9: ...ado Tenga cuidado de no doblar o da ar el anillo de fijaci n cuando instale el conducto No exceda la longitud m xima de los conductos de 25 pies 7 6 m Configuraci n de la presi n negativa El HEPA 700...

Page 10: ...de la velocidad m xima del ventilador cuando se instala un filtro primario que no sea de Legend Brands Para obtener el m ximo rendimiento de la filtraci n utilice s lo filtros Legend Brand No intente...

Page 11: ...crocristal 124966 1 pq 125028 8 pq Este equipo se ha probado y se ha comprobado que cumple con los l mites de un dispositivo digital de clase B de acuerdo con la parte 15 de las normas de la FCC Estos...