report set
point/
regulation
mode
Reports output set point level (set with
command
8
) and the active regulation
mode (set with command
3
).
The controller returns three data bytes:
• Bytes 1 and 2 represent the set point
value.
• Byte 3 reports the regulation mode:
4
6 = Forward power regulation
(P
forward
)
4
7 = Load power regulation (P
real
)
4
8 = External power regulation (DC
Bias)
0
3
165
report
forward
power
Reports a snapshot of forward power
level at that instant.
The controller returns two data bytes
representing the forward power in watts
(LSB first).
0
2
166
report
reflected
power
Reports a snapshot of reflected power
level at that instant.
The controller returns two data bytes
representing the reflected power in watts
(LSB first).
0
2
167
report
delivered
power
Reports a snapshot of delivered power
level at that instant.
The controller returns two data bytes.
Both bytes represent delivered power
(LSB first).
0
2
168
report
external
feedback
(DC Bias)
Reports a snapshot of external feedback
level at that instant.
The controller returns two data bytes
representing the external feedback (LSB
first).
0
2
Table 4-13. Host port commands (Continued)
Command
Description
Number of
Host Data
Bytes
Number of
Response
Data Bytes
Summary of Contents for 13150 400 V
Page 2: ......
Page 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Page 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...