Setting the Unit’s PROFIBUS Network Address
Use the rotary address switches next to the
PROFIBUS
port on the rear panel
to set the HPG generator's address. Allowable addresses are numbers
between 0 and 126, selected in hex format.
To enter the unit's address, set the switch positions for hex representation.
The following example demonstrates switch settings for an address of12:
0 C = 0x0Ch = 12.
Note:
The unit’s address can only be changed from the
PROFIBUS
master if
the hardware address is above 126.
PROFIBUS Termination
Please ensure that you follow proper termination procedures if your HPG
generator is the last slave on the
PROFIBUS
cable. The termination resistors
should be on the connector housing of the
PROFIBUS
cable (not included).
PROFIBUS Baud Rate
The auto-baud feature of Dressler’s certified
PROFIBUS
interface adjusts
automatically to the rate of the PROFIBUS master system. Baud rates are
available in discrete steps from 9600 bits (9.6 kbits) to 12 Mbits. The auto-
baud feature operates much like a modem or FAX machine in that, at startup,
there is a small delay while the interface
traverses
the different baud rates and
then locks in. Please ensure that your PROFIBUS master allows for this delay.
PROFIBUS Status LEDs
The PROFIBUS LEDs (light-emitting diodes) on the rear panel consist of two
status LEDs to indicate whether the PROFIBUS system is operating properly.
See
.
describes the LED states and associated PROFIBUS status.
Table 4-5. PROFIBUS status LEDs
LED
Indication
Unit Status
Green (steady)
Operational
The PROFIBUS system is
ready and operational.
Summary of Contents for 13150 400 V
Page 2: ......
Page 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Page 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Page 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...