Installation
2-8
April 2003
Part No. 917404-001 Rev. B
1.
Turn power
Off
to the site controller.
2.
Place a wrist strap, (Wayne part number 916962, 3M Charge Guard 2213, or equivalent), on your
wrist and clip the grounding end to the chassis of the power supply in the site controller.
3.
If there is a PIB/Plus board in slot 6, remove it.
4.
Install the HyperPIB board in slot 2 (remove the 2400/Plus CPU board on this slot if there is one)
of the site controller. Refer to Figure 2-1. Place the HyperPIB board with the component side
facing toward the power supply.
5.
Check the site controller cabinet for loose tools or parts.
6.
Remove the grounding end of the wrist strap from the power supply and close the cabinet door.
7.
Turn power
On
to the site controller.
8.
To check the HyperPIB software version, enter mode 90 and submode 08 on the 2400 console,
then press the PRNT/ENTR key. The console screen displays the HyperPIB version in the
following format: VVWWYY00, where VV is the HyperPIB version number, WW and YY the
week and year when the software is released.
Note: If the HyperPIB version does not appear on the console screen, the HyperPIB board is not
communicating with the 2400 console. If the checksum does not equal zero, the HyperPIB firmware
or hardware is not operating correctly and must be replaced.
9.
To check the HyperPIB software checksum, enter mode 90 and submode 07 on the 2400 console,
then press the PRNT/ENTR key. The console screen displays the software checksum. The
checksum should equal zeroes if a production release version of code is present.
10.
Turn power to the site controller
Off.
11.
Remove the six screws securing the metal plate to the hinge side of the site controller. Discard the
metal plate. Install the new side panel (part number 850258-04).
12.
Connect the 10-pin AMP connector end of cable, part number 887902-001, to J1 on the
HyperPIB board, then connect the 25-pin DB connector end to slot J1 on the side panel of the site
controller using the screw assembly #5010303.
13.
Connect the 10-pin AMP connector end of cable, part number 887902-001, to J2 on the
HyperPIB board, then connect the 25-pin DB connector end to slot J2 on the side panel of the site
controller using the screw assembly #5010303.