![Dresser iCIP 100 Series Installation & Operations Procedures Manual Download Page 12](http://html.mh-extra.com/html/dresser/icip-100-series/icip-100-series_installation-and-operations-procedures-manual_2530903012.webp)
1
2
Head Size
Number of
Heads
RPM Range
Volume Range
Quarts (Liters) per Day
Pressure Range (psi)
Low
High
Low
High
Standard
High
Pressure
3/16”
Single
5
65
2.9 (2.8)
38.0 (35.9)
0-5000
5000-7000
Duplex
5
65
2.9 (2,8)
76.0 (71.9)
0-5000
5000-7000
Triplex
5
65
2.9 (2,8)
114.0 (107.8)
0-5000
5000-7000
1/4”
Single
5
65
5.1 (4.8)
66.6 (63.0)
0-5000
0-5000
Duplex
5
65
5.1 (4.8)
133.2 (126.0)
0-5000
0-5000
Triplex
5
65
5.1 (4.8)
199.8 (189.0)
0-5000
0-5000
3/8”
Single
5
65
11.5 (10.9)
149.8 (141.7)
0-1500
1500-3000
Duplex
5
65
11.5 (10.9)
299.8 (283.5)
0-1500
0-1500
Triplex
5
65
11.5 (10.9)
449.4 (425.2)
0-1500
0-1500
1/2”
Single
5
65
20.5 (19.4)
266.2 (252.2)
0-1000
0-1000
Duplex
5
65
20.5 (19.4)
534.4 (503.8)
0-1000
0-1000
Triplex
5
65
20.5 (19.4)
798.6 (755.7)
0-500
0-500
Texsteam HiCIP
*
Pump
The Texsteam HiCIP solar-powered pump combines the intelligence of the
iCIP solar pump with the ability to pump almost 800 quarts per day,
44% more volume per head than the standard iCIP pump. The HiCIP pump
does the work of 2 to 3 lower volume pumps thereby reducing the cost of
ownership. With only one pump running, maintenance expenses
are reduced.
■
65 RPM motor allows for 44% more volume per head than the iCIP
pump
■
Variable speed continuous-duty brushless motor design
■
Same features and benefits as the iCIP pump
■
Available in Series 100, 200, 300 and 400
■
Available in duplex and triplex configurations for volume requirements
over 266.2 quarts/day
■
Solar pump with the capacity of 798.6 quarts/day (199.65 GPD) with the
triplex configuration