Parameter
Device 1
Device 2
Trigger Sensor
Sensor1
Sensor1
Delay ms
000.0
000.2
Bulb sec
01
00
Prefocus
No
No
Device Settings
Parameter
Sensor1
Sensor2
Trigger Type
Low
Low
Trigger Value
100
000
Power
Off_Sen2
On
Sensor Settings
The camera should be set to manual mode and the aperture and shutter speed should be set as
appropriate for the flash value. The delay for Device 2 (the flash) is to allow the shutter on the camera
to open before the flash triggers. The Power setting of Off_Sen2 turns the laser off before the camera
is triggered to keep the laser beam from being in the shot. The shot will be triggered when the light
sensor value goes below 100 (this value may need to be adjusted up or down depending on the
sensor reading when the laser is on verses off the light sensor).
Microphone Sensor
The microphone sensor is a basic sound activated sensor that is used to trigger devices based on
sharp/loud sound changes. An example of how the microphone sensor would be used is described
below.
Using a microphone sensor plugged into the Sensor 2 port and a flash connected to Camera/Flash
1, the user would like the flash to trigger 1/2 second after the microphone triggers. The following
settings could be used to set this up. In this case the settings for Device1 and Sensor2 are configured
according to the table below. Device2 should have the Trigger Sensor set to None and Sensor2 will
be ignored.
Parameter
Device 1
Device 2