background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 

ME3100 Analog Circuit Design 

Ready-to-Teach Package for Electronic Instrumentation and Measurement 

 
 
 

Quick Start Guide 

revision 2.00 

Printed on 29 June 2016

 

 

 
 

 

 
 
 

 
 

 

 

Summary of Contents for ME3100

Page 1: ...ME3100 Analog Circuit Design Ready to Teach Package for Electronic Instrumentation and Measurement Quick Start Guide revision 2 00 Printed on 29 June 2016...

Page 2: ...the requirements of the Low Voltage Directive 73 23 EEC and EMC Directive 89 336 EEC and carries the CE marking CAUTION ESD THIS PRODUCT CONTAINS ELECTRONIC COMPONENTS SENSITIVE TO ELECTROSTATIC DISCH...

Page 3: ...Design Quick Start Guide 3 25 Table of Contents Table of Contents 3 1 Quick Setup and Verification 4 2 Support and Warranty 9 Appendix A ME3100 Analog Circuit Design Kit 10 Appendix B Specifications...

Page 4: ...erted into the Embedded Audio Sound Module M1 that is located at the left corner of the ME3100 Analog Circuit Design kit 3 Turn on the power supply unit Set one of the dual channel output voltages to...

Page 5: ...iding a constant voltage supply to the ME3100 Analog Circuit Design kit 10 If the CC annunciator is on disable the power supply output Check if this is due to a current limit setting or a faulty conne...

Page 6: ...o the appendix for the pin layout of the op amp LM158 Figure 4 Single Band Equalizer with VU Meter 2 Table 1 shows the value of the electronics components in the schematic Table 1 Value of Components...

Page 7: ...ith VU Meter 3 Table 2 shows the value of the electronics components of the schematic Table 2 Value of Components Label Value R1 1 5 k RF 120 k RL 330 CF1 560 nF CF2 2 2 F CF3 150 nF CL1 1 2 nF CL2 4...

Page 8: ...n the microSD memory card The LED D1 will be turned on when the module is playing the audio file 8 The LEDs D2 D9 of the UV meter will visualize the output of the equalizer when the audio file is play...

Page 9: ...hipment be free from defects in material and workmanship and will conform to Acehub Vista Sdn Bhd s applicable specifications If Acehub Vista Sdn Bhd receives notice of a defect or non conformance dur...

Page 10: ...E3100 Analog Circuit Design Kit As shown in Figure A 1 the ME3100 Analog Circuit Design kit consists of the following Audio Speaker Embedded Audio Player LED Audio UV Meter Analog Potentiometer Seven...

Page 11: ...ETY This product is rated for indoor use only EMC IEC 61326 1 2005 EN 61326 1 2006 Canada ICES NMB 001 Issue 4 June 2006 Australia New Zealand AS NZS CISPR 11 2004 DIMENSIONS W x H x D 230 mm x 65 mm...

Page 12: ...http dreamcatcher asia cw cw enquiry dreamcatcher asia ME3100 Analog Circuit Design Quick Start Guide 12 25 Appendix C Pin Layout of LM158 Figure C 1 Pin Layout of LM158...

Page 13: ...the U2741A there are two LED indicators The power indicator lights up once the U2741A is powered on There is a system error if the indicator blinks after the U2741A is powered on The USB indicator wil...

Page 14: ...ltage measurement Measuring DC Current 1 The DC current measurement function of the U2741A has the following features three ranges to select 10 mA 100 mA 1 A and 2 A or auto range input impedance is 1...

Page 15: ...function generator after the desired parameters are set 14 The U2761A is able to output five standard waveforms that are Sine Square Ramp Triangle Pulse and DC 15 You can select one of the three built...

Page 16: ...the interface Table D 2 Features of the AMM Function Generator Interface No Panel Features 1 Waveform Pattern Selection Select various types of output function by clicking the buttons 2 Waveform Para...

Page 17: ...e in Vrms Duty Cycle Limitations For Square waveforms the U2761A may not be able to use the full range of duty cycle values at higher frequencies as shown below 20 to 80 frequency 10 MHz 40 to 60 freq...

Page 18: ...specify the output amplitude in dBm if the output termination is currently set to high impedance The units are automatically converted to Vpp You may configure the output termination by clicking Tool...

Page 19: ...the PC using a USB cable 2 Power on the oscilloscope 3 Launch the Keysight IO Control and the Keysight Measurement Manager AMM 4 The Select USB Device dialog box will appear displaying the connected U...

Page 20: ...the signal 4 Configuration summary Displays the configured functions and settings 5 Waveform graph display Displays the output of the data acquired 6 Scope control tabs Consists of all the sub functio...

Page 21: ...below Figure D 107 Channel On Off Mode 3 The channel options provide four types of adjustment to the channel waveform these options are AC Coupling Invert BW Limit and Attenuation 1X 10X 100X You may...

Page 22: ...ase Delay and Mode for the horizontal scale adjustment This is shown in Figure D 13813 Figure D 138 Soft Front Panel of the Horizontal System Controls 9 Time base allows you to control how often the v...

Page 23: ...n the toolbar of the soft front panel 2 Click to activate the automated measurement and cursor system This will display the window as shown below Figure D 16 Soft Front Panel of the Measurement and Cu...

Page 24: ...Stop 1 AutoScale automatically configures the oscilloscope to best display the input signal by analyzing any waveforms connected to the channel and external trigger inputs If AutoScale fails your curr...

Page 25: ...tronic mechanical photocopying recording or otherwise without prior written permission of Acehub Vista Sdn Bhd Every effort has been made to ensure that the information in this manual is accurate Aceh...

Reviews: