ME3000 Analog Electronics        

                          

Lab 6 - 15/19  

 

                     

 

Agilent Measurement Manager Soft Front Panel (Oscilloscope)

 

 

 

Figure B-35 – Soft Front Panel of the Oscilloscope 

 

Figure 

B-35

B-3  shows  the  graphic  user  interface  of  Agilent  Modular  Oscilloscope  under  Agilent 

Measurement  Manager  together  with  the  label  of  each  panel.  Table 

B-1

B-1  shows  the  features  of 

each panel of the interface. 

Table B-1 – Features of the AMM Oscilloscope Interface 

 

No.  Panel 

Description 

Oscilloscope toolbar 

Consists of oscilloscope tools 

Waveform Acquisition tab 

Displays the time-domain waveform for the oscilloscope 

FFT Analysis tab 

Displays the FFT spectrum of the signal 

Configuration summary 

Displays the configured functions and settings 

Waveform graph display 

Displays the output of the data acquired 

Scope control tabs 

Consists of all the sub functions of the oscilloscope 

Measurement Results panel 

Displays the measurement results of the scope operations 

Status tab 

Displays the status panel, which shows the history of operations 

Refresh rate 

Displays the graph update rate in frame/sec. 

10 

Video Sampling Rate 

Displays the video sampling rate (in number of samples per second taken from a 
continuous signal) 

11 

Calibration Delta Temp. 
indicator 

Displays the calibration delta temperature of the connected device 

 

Analog Controls 

 

Summary of Contents for ME3000 Analog Electronics Lab 6

Page 1: ...signing an RF tuned amplifier ii To demonstrate AC measurements on a Class A amplifier Equipment Required i ME3000 M2 Analog Electronics Training Kit ii Digital Multimeter recommendation Agilent 34405...

Page 2: ...gion is almost linear Two types of amplifiers can be designed tuned and untuned amplifiers An untuned amplifier has a wider bandwidth than a tuned amplifier as shown in Figure 1 A tuned amplifier cons...

Page 3: ...between 1 MHz to 300 MHz Great care must be taken in designing an RF amplifier as most of the components will not portray ideal characteristics at radio frequencies Most of the RF Class A amplifiers...

Page 4: ...etails 5 Use the multimeter to measure VCC applied to the transistor between terminals TP4 and GND Calculate the voltage at the transistor base using the resistive voltage divider formula CC B V R R R...

Page 5: ...to 8 MHz in 100 kHz increments 17 Record the peak to peak voltage at the input CH 1 and output CH 2 and determine the magnitude of the voltage gain AV as a function of frequency 18 Plot the AV versus...

Page 6: ...25 Connect the oscilloscope CH1 to TP1 and GND 26 Connect the oscilloscope CH2 to TP6 and GND 27 Set the trigger signal to CH1 28 Record the peak to peak voltage at the input CH 1 and output CH 2 and...

Page 7: ...urrent limit to 0 5 A Next set the supply to 25 V positive supply Set the voltage to 15 V and current limit to 0 5 A Repeat the same procedure for 25 V negative supply to set the voltage to 15 V and c...

Page 8: ...e U2741A there are two LED indicators The power indicator lights up once the U2741A is powered on There is a system error if the indicator blinks after the U2741A is powered on The USB indicator will...

Page 9: ...make a DC voltage measurement Measuring DC Current 1 The DC current measurement function of the U2741A has the following features three ranges to select 10 mA 100 mA 1 A and 2 A or auto range input i...

Page 10: ...he output of the function generator after the desired parameters are set 14 The U2761A is able to output five standard waveforms that are Sine Square Ramp Triangle Pulse and DC 15 You can select one o...

Page 11: ...ch panel of the interface Table A 2 Features of the AMM Function Generator Interface No Panel Features 1 Waveform Pattern Selection Select various types of output function by clicking the buttons 2 Wa...

Page 12: ...for Sine wave in Vrms Duty Cycle Limitations For Square waveforms the U2761A may not be able to use the full range of duty cycle values at higher frequencies as shown below 20 to 80 frequency 10 MHz 4...

Page 13: ...to half You cannot specify the output amplitude in dBm if the output termination is currently set to high impedance The units are automatically converted to Vpp You may configure the output terminati...

Page 14: ...he oscilloscope to the PC using a USB cable 2 Power on the oscilloscope 3 Launch the Agilent IO Control and the Agilent Measurement Manager AMM 4 The Select USB Device dialog box will appear displayin...

Page 15: ...quisition tab Displays the time domain waveform for the oscilloscope 3 FFT Analysis tab Displays the FFT spectrum of the signal 4 Configuration summary Displays the configured functions and settings 5...

Page 16: ...rom channel 1 channel 2 click 1 2 or press the shortcut key F5 F6 2 To toggle the channel on or off click the channel buttons on the vertical control panel or click the toolbar to toggle the channel o...

Page 17: ...orizontal scale causes the waveform to expand or contract in the center of the screen It provides functions of Time Base Delay and Mode for the horizontal scale adjustment This is shown in Figure B 87...

Page 18: ...n is located on the toolbar of the soft front panel 2 Click to activate the automated measurement and cursor system This will display the window as shown below Figure B 11 Soft Front Panel of the Meas...

Page 19: ...Scale and Run Stop 1 AutoScale automatically configures the oscilloscope to best display the input signal by analyzing any waveforms connected to the channel and external trigger inputs If AutoScale f...

Reviews: