Dražice OKHE 100-SMART Operating And Installation Manual Download Page 30

- 30 -

 

 

5

 

IMPORTANT NOTICES 

5.1

 

INSTALLATION REGULATIONS 

-

 

Without  a  confirmation  of  performed  electrical  installation  issued  by  an  authorised  company,  

the warranty certificate shall be void. 

-

 

Check and exchange the Mg anode regularly. 

-

 

You have to apply for approval of a local power supplier to connect the heater. 

-

 

No stop valves can be put between the heater and the safety valve. 

-

 

If the overpressure in the water main exceeds 0.48 MPa, a pressure control valve must be mounted 

before the safety valve. 

-

 

All hot water outputs must have a combination faucet. 

-

 

Before  filling  the  heater  with  water  for  the  first  time,  it  is  recommended  to  fasten  the  flange 

connection nuts of the tank. 

-

 

It is not allowed to handle the thermostat, aside from temperature resetting with a control button. 

-

 

All electric installation handling, adjustment and replacement of the regulation elements shall only 

be performed by an authorised service company. 

-

 

The thermal fuse must not be turned off!

 In case of thermostat defect, the thermal fuse interrupts 

electric power input to the heating element if the water temperature in the heater exceeds 90 °C. 

 

 

Both  the  electric  and  water  installation  must  follow  and  meet  the  requirements  and 
regulations relevant in the country of use!

 

 

5.2

 

DISPOSAL OF PACKAGING MATERIAL AND NON-
FUNCTIONING PRODUCT 

 

30-9-2015 

 

A service  fee for providing return and recovery of packaging material has been paid 
for the packaging in which the water heater was delivered. The service fee was paid 
pursuant to Act No 477/2001 Coll., as amended, at EKO-KOM a.s. The client number of 
the company is F06020274. Take the water boiler packages to a waste disposal place 
determined by the town. When the operation terminates, disassemble and transport 
the discarded and unserviceable heater to a waste recycling centre (collecting yard), 
or contact the manufacturer.  

 

Summary of Contents for OKHE 100-SMART

Page 1: ...TION MANUAL TANK TYPE WATER HEATER FOR VERTICAL MOUNTING OKHE 80 100 125 160 SMART Dru stevn z vody Dra ice stroj rna s r o Dra ice 69 294 71 Ben tky nad Jizerou tel 420 326 370 990 Fax 420 326 370 98...

Page 2: ...11 2 4 ELECTRIC WIRING 12 2 4 1 ELECTRIC INSTALLATION GENERAL INFORMATION 12 2 4 2 ELECTRONIC THERMOSTAT CONNECTION DIAGRAM 13 2 5 FIRST HEATER COMMISSIONING 14 2 6 PUTTING OUT OF SERVICE DISCHARGE 14...

Page 3: ...WARE FOR MOBILE DEVICES 23 4 1 1 BASIC DESIGN 23 4 1 2 PAIRING SCREEN 24 4 1 3 MODE SECTION 24 4 1 4 PROGRAM SECTION 25 4 1 5 VACATION SECTION 27 4 1 6 STATISTICS SECTION 27 4 1 7 SETTING SECTION 28 4...

Page 4: ...nstruction maintenance and other information on electrical water heaters The manufacturer reserves the right for engineering modification of the product The product is designed for permanent contact w...

Page 5: ...rmostat with reaction to the consumption of hot water SMART HDO SMART mode with signal memory HDO 2 MANUAL Common thermostat MANUAL HDO Common thermostat blocked with signal HDO 3 PROG Common thermost...

Page 6: ...nual setting of the required temperature set it only for the value which you need for the household operation Thus you will reduce electricity consumption as well as the amount of lime sediments on th...

Page 7: ...MPTION FOR WARMING CONTENTS FROM 15 C TO 65 C kWh 4 8 6 8 9 5 TOTAL HEAT LOSSES kWh 24h 0 72 0 83 1 00 1 32 LOAD PROFILE M M M L DAILY ELECTRICITY CONSUMPTION kWh 6 19 6 31 6 59 12 03 WEEKLY ELECTRICI...

Page 8: ...es the automatically measured anode rod The main electrical installation is placed in the plastic box assembled directly on the flange lid Water temperature and other comfort functions can be set mech...

Page 9: ...NS Figure 2 OKHE 80 SMART OKHE 100 SMART OKHE 125 SMART OKHE 160 SMART A 730 875 1040 1237 B 731 876 1041 1223 C 578 724 754 1010 D 520 520 520 520 E 556 556 556 556 F 15 15 15 15 G 115 115 115 115 R...

Page 10: ...liance or the thermostat to be set to minimum operation temperature of 60o C For proper operation drinkable water of adequate quality shall be used To avoid potential sediments we recommend that the d...

Page 11: ...alve must be easily accessible as close to the heater as possible The inlet pipes must have at least the same clearance as the safety valve Safety valves with fixed pressure settings from the manufact...

Page 12: ...potential disassembly or repair When assembling the security equipment follow u268 CSN 06 0830 2 4 ELECTRIC WIRING Do not plug the water heater in HDO socket it would not work properly in SMART mode...

Page 13: ...aker disconnecting all poles of the network and a circuit breaker protector Installations in bathrooms lavatories and showers must comply with the SN 33 2000 7 701 standard To adjust the distance from...

Page 14: ...n the combination faucet 3 Open the cold water inlet valve to the heater 4 As soon as the water starts running through the hot water valve the heater is filled and the valve can be closed 5 In case of...

Page 15: ...utdown that exceeds 5 days Caution In doing so the cold water supply pipe and the connection fitting of the tank may get heated If the hot water heater does not work or if hot water is not withdrawn n...

Page 16: ...ter that user consumes in relevant time leaving a certain reserve for case of unexpected water withdrawal In this phase water consumption data are collected and evaluated The obtained information is a...

Page 17: ...heating spiral is blocked 3 1 5 OPTIMUM IN MODE MANUAL AND MANUAL HDO Recommended temperature for manual setting 55 C During this temperature the best efficiency of smart heater is achieved 3 1 6 PRO...

Page 18: ...cludes the four digit seven segment LED display additionally to the heater The display example is below 3 3 FUNCTION DESCRIPTION In basic mode the panel displays water temperature and uses the light o...

Page 19: ...ve mode ANTI FREEZE MODE DZ centre red Indication of active heating spiral gradual change of the light intensity with period approx 2 s permanent light in rest state Table 5 List of symbols 1 LED ANTI...

Page 20: ...ifu najdete na www eon cz nizkytarif Pro zji t n platnosti doby n zk ho tarifu pro va e k dy zde sta zadat prvn uveden k d HDO kter naleznete na p stroji Pokud jste z oblasti ji n Moravy je k d HDO tv...

Page 21: ...pages of electricity distributor also list the accurate times of your cheap and expensive product tariffs The frequency is always at the HDO receiver e g in figure 9 the frequency is 216 66Hz Referen...

Page 22: ...TURE SETTING After turning the controller within scope of MANUAL mode temperature setting the display indicates the flashing temperature value which complies with the actual controller setting After f...

Page 23: ...1 BASIC DESIGN The mobile application automatically adjusts the size and design of some user interface parts according to the display size and its turning width height In case of width display the mon...

Page 24: ...chapter 4 1 7 Setting section 4 1 3 MODE SECTION After pairing the thermostat with the mobile device the width display in section Mode is set as the home screen in case of height display it displays...

Page 25: ...hours in a week is performed by means of the field with round buttons in two steps After the first pressing of the specified round button the initial option location is marked then it is necessary to...

Page 26: ...26 Figure 12 Setting the program mode Figure 13 Notification of the program mode...

Page 27: ...r operation by means of annual graph for the last year and the last week together with total consumption Total consumption is measured from the day of the first boiler start or after pressing button R...

Page 28: ...and it is possible to activate or deactivate the HDO function It is possible to set the name of the connected boiler which is suitable in situation the user owns more SMART heaters and it is necessary...

Page 29: ...ZING TIME After the application start the actual thermostat time is automatically checked If the time differs from the time in the mobile device the user can press the button Synchronize to set time i...

Page 30: ...and replacement of the regulation elements shall only be performed by an authorised service company The thermal fuse must not be turned off In case of thermostat defect the thermal fuse interrupts ele...

Reviews: