5
Temperature setting
Water temperature is set by turning the thermostat knob. The desired symbol is adjusted against the fixed point on
the control panel.
Notice:
Adjusting the thermostat selector at the left backstop does not mean permanent shutoff of the heating
element.
When the heater is in use without blocking the daily rate, we do not recommend the temperature to be set above
60°C.
The maximum value to select is “
60“
.
Limiting the regulation range; locked settings.
For various safety reasons (unintentional scalding, preventing children or unauthorised person from handling), the
regulation range can be
limited
, or the setting on the thermostat
blocked
.
Regulation limited
- pull off the thermostat knob (it will be tough at first) and you will find two cylindrical
pins
2,15mm on the back side of the knob
- pull off one pin and insert it to the corresponding hole of the selected maximum
temperature.
- put the knob back on (to the stop)
Setting blocked – set the selected temperature
pull off the thermostat knob without changing the setting and you will find two pins on the back
side of the knob; pull both of them and fit them into the holes corresponding with the selected
temperature so that the gap between the pins was without a hole, and the position was opposite
the set temperature.
Lower temperature range
limit (about 5°C)
Fixed point on the control
panel
Anti-freezing temperature
(about 8°C)
Upper temperature range
limit (about 74°C)
”Ideal” temperature (about
60°C)
Regulation limited
Setting blocked