- 13 -

 

 

2.6

 

SPARE PARTS 

-magnesium anode

 

 

When ordering spare parts always state the name of the part, the type and type number from the tank's plate.

 

3

 

IMPORTANT NOTICES 

3.1

 

IMPORTANT NOTICES 

 
Without a proof issued by a professional company about performed electrical and plumbing 
fixture the warranty shall be void. 
 
It is necessary to check the protective magnesium anode periodically and replace it if necessary. 
 
No closing armature may be mounted between the tank and the safety valve. 
 
All outlets of hot water must be equipped with combination faucets. 
 
Prior  to  the  first  filling  the  tank  with  water  we  recommend  that  the  receptacle's  flange 
connection nuts are tightened. 
 

3.2

 

INSTALLATION REGULATIONS 

 
Both the electric and water installation must follow and meet the requirements and regulations 
relevant in the country of use! 
 

3.3

 

DISPOSAL OF PACKAGING MATERIAL AND NON-
FUNCTIONING PRODUCT 

A  service  fee  for  providing  return  and  recovery  of  packaging  material 
has been paid for the packaging in which the product was delivered The service 
fee was paid pursuant to Act No. 477/2001 Coll., as amended, at EKO-KOM a.s. 
The client number of the company is F06020274. Take the water tank packages 
to  a  waste  disposal  place  determined  by  the  municipality.  Disassemble 
the  discarded  and  unserviceable  product  after  the  operation  terminates, 
and  transport  it  to  a  waste  recycling  centre  (collecting  yard),  or  contact 
the manufacturer. 

 

12-10-2018 

Summary of Contents for OKC 400 NTRR/HP/SOL

Page 1: ...ECT WATER TANKS OKC 400 NTRR HP SOL OKC 500 NTRR HP SOL Dru stevn z vody Dra ice stroj rna s r o Works Cooperative Dra ice Machine Plant Ltd Dra ice 69 294 71 Ben tky nad Jizerou tel 420 326 370 911 f...

Page 2: ...FITTING INSTRUCTIONS 8 2 1 COMMISSIONING THE RESERVOIR 8 2 2 CONNECTING THE RESERVOIR TO HOT WATER DISTRIBUTION 9 2 3 PLUMBING FIXTURE 10 2 4 CONNECTION OF TANK TO HOT WATER DISTRIBUTION SYSTEM 11 2 5...

Page 3: ...onsible person or unless properly instructed by such responsible person The manufacturer reserves the right for engineering modification of the product The product is designed for permanent contact wi...

Page 4: ...heating circuit lower tubular heat exchangers is designed for solar system The tank is placed on the ground next to the heating water source or in its vicinity All connecting distributions must be pro...

Page 5: ...SURE IN THE VESSEL MPa 1 MAXIMUM OPERATING OVERPRESSURE IN THE EXCHANGER MPa 1 MAXIMUM HEATING WATER TEMPERATURE C 110 MAXIMUM OPERATING TEMPERATURE IN THE VESSEL C 80 HEATING SURFACE OF UPPER LOWER E...

Page 6: ...KC 400 NTRR HP SOL Figure 1 Table 2 OKC 400 NTRR HP SOL A 1644 B 812 C 857 D 700 E 55 F 1521 G 973 I 723 J 288 L 208 M 648 N 812 O 1348 P 355 R 1073 S 1173 1 outer 3 4 inner 5 4 inner 1 2 inner 6 4 in...

Page 7: ...KC 500 NTRR HP SOL Figure 2 Table 3 OKC 500 NTRR HP SOL A 1914 B 812 C 857 D 700 E 55 F 1790 G 1023 I 773 J 288 L 228 M 609 N 818 O 1618 P 473 R 1123 S 1409 1 outer 3 4 inner 5 4 inner 1 2 inner 6 4 i...

Page 8: ...he way in first the operating and then the safety thermostat b open the hot water valve on the combination faucet c Open the cold water inlet valve to the tank d when the water starts flowing through...

Page 9: ...ssel The safety valve does not replace the safety valve on the cold water inlet No closing return armature and filter may be mounted between the heater and the safety valve T fixtures with discharge v...

Page 10: ...e guide provided by the safety equipment manufacturer It is necessary to check the safety valve each time before putting it into operation It is checked by manual moving of the membrane from the seat...

Page 11: ...way valve backflow flaps and the exchanger from sedimentation It is recommended to flush the heating circuit before the assembly All wiring connections must be properly insulated from heat If the sys...

Page 12: ...rease the temperature of hot service water HSW periodically for a transitional period of time to at least 70 It is also possible to make use of another way of disinfecting HSW PROCEDURE OF EXCHANGING...

Page 13: ...t the receptacle s flange connection nuts are tightened 3 2 INSTALLATION REGULATIONS Both the electric and water installation must follow and meet the requirements and regulations relevant in the coun...

Reviews: