- 30 -
3
IMPORTANT NOTICES
3.1
INSTALLATION REGULATIONS
Without a proof issued by a professional company about performed electrical and plumbing
fixture the warranty shall be void.
It is necessary to check the protective magnesium anode periodically and replace it if
necessary.
No closing armature may be mounted between the tank and the safety valve.
If the overpressure in the eater main exceeds 0.48 MPa, a reduction valve must be mounted
before the safety valve.
All outlets of hot water must be equipped with combination faucets.
Prior to the first filling the tank with water we recommend that the receptacle's flange
connection nuts are tightened.
It is not allowed to handle the thermostat, aside from temperature resetting with a control
button.
All electric installation handling, setting, and regulation feature exchange, may only be
implemented by a service company.
The thermal fuse must not be turned off! In case of a thermostat defect, the thermal fuse
interrupts electric power supply to the heating element if the water temperature in the tank
exceeds 95°C.
As an exception, the thermal fuse may also switch off due to water overheating caused
by overheating the hot water heating system boiler (in case of a combined tank).
We recommend that the tank is only operated on one energy source.
If you don't use the heater (hot water tank) for longer than 24 hours, or if the facility
with heater is unattended, close the cold water inlet to the heater.
The heater (hot water tank) shall be used exclusively in accordance with the conditions
specified on the performance plate and in the instructions for electric wiring.
Both the electric and water installation must follow and meet the requirements
and regulations relevant in the country of use!