![Drazice OKC 160 NTR/HV Operating And Installation Manual Download Page 29](http://html1.mh-extra.com/html/drazice-0/okc-160-ntr-hv/okc-160-ntr-hv_operating-and-installation-manual_2529673029.webp)
- 29 -
PROCEDURE OF EXCHANGING ANODE ROD IN UPPER HEATER PART
1.
Turn off control voltage to the tank
2.
Drain water from 1/5 tank.
PROCEDURE: Close water inlet in the tank
Open the hot water valve on the combination faucet.
Open the drain tap of the tank
3.
Anode is screwed in under the plastic cover in the upper lid of the tank
4.
Unscrew the anode using adequate wrench
5.
Pull the anode out and follow reversed steps to install a new one
6.
During the fitting, make sure the grounding cable (300 - 500l) is connected properly; this is
the condition of the anode's proper functioning
7.
Fill the tank with water
PROCEDURE OF EXCHANGING ANODE ROD IN SIDE FLANGE
1.
Turn off control voltage to the tank
2.
Drain water from the tank.
PROCEDURE: Close water inlet in the tank
Open the hot water valve on the combination faucet.
Open the drain tap of the tank
3.
One anode is screwed in under the plastic cover in the upper lid of the tank, and the other one is
screwed in on the side flange
4.
Unscrew the anode using adequate wrench
5.
Pull the anode out and follow reversed steps to install a new one
6.
Fill the tank with water
The list of heaters with anode in the side flange:
OKC 200 NTR/BP
OKC 200 NTRR/BP
OKC 250 NTR/BP
OKC 250 NTRR/BP
OKC 300 NTR/BP
OKC 300 NTRR/BP
OKC 400 NTR/BP
OKC 400 NTRR/BP
OKC 500 NTR/BP
OKC 500 NTRR/BP
2.8
SPARE PARTS
- flange lid
- flange lid seal
- insulation flange lid
- thermostat and thermal
-magnesium anode
- control button for the
fuse
thermostat
- control lights with wires
- orientation temperature indicator - set of M12 (or M10) bolts
When ordering spare parts always state the name of the part, the type and type number from the tank's
plate.