SIX-PACK” OPERATORS’ MANUAL
11
TECHNICAL SPECIFICATIONS
(Measurements taken at +4dBu operating level where applicable)
INPUT IMPEDANCE
20K
S
MAXIMUM INPUT LEVEL
+20dBu
OUTPUT IMPEDANCE
50
S
(bal), 100
S
(unbal)
MAXIMUM OUTPUT LEVEL
+20dBu
BANDWIDTH
<10Hz to 22KHz -1dB
NOISE AT UNITY GAIN
with Expander Off
Wideband
22Hz - 22KHz
CCIR ARM
IEC A
Q-Pk CCIR
AV
-90dB
-95dB
-95dB
-97dB
-84dB
RMS
-88dB
-93dB
-93dB
-95dB
-82dB
DISTORTION
100Hz
1KHz
10KHz
Unity Gain, +4dBu input
< 0.03%
< 0.02%
<0.03%
+14dBu input, 10dB Gain Red.
< 0.1%
< 0.1%
< 0.1%
POWER REQUIREMENTS
115Volt or 230Volt at 50-60Hz, 9 Watts
FUSE RATING
32mA for 230Volt,
63mA for 115Volt
CONFORMING TO BS EN 60127-2:1991 SHEET III
FUSE TYPE
20mm x 5mm, Class 3 Slo-Blo, 250Volt working
CASE SIZE
482mm (w) x 44mm (h) x 200mm (d)
WEIGHT
(incl packaging)
3.2 Kgs