CONTROL DESCRIPTION

Both channels of the DL241 are identical and may be used completely independently or
linked for stereo operation. In the linked mode, only the left hand channel controls are
functional and serve as master controls, though the channel bypass switches remain
independent. In linked mode, the compressor / limiters, peak limiters and expanders of
the two channels track together to avoid the inevitable image shifting that occurs if the
two channels of a stereo signal are treated independently.

EXPANDER

Threshold

:

 

This control sets the level below which expansion  starts to take
place  and  may  be  set  in  the  range  -70dB  to  +20dB.  W hen  the
expander starts to operate, the red status LED will come on. Note:
because the expansion ratio varies with signal level, it is possible
to  arrive  at  a  situation  where  the  red  expansion  LED  may  be
illuminated  when  little  or  no  perceived  gain  reduction  is  taking
place. This means that the expansion Threshold may need to be
set a little higher than it would with a conventional expander and
final setting is best done by ear. The adaptive expansion system
used  in  the  DL241  means,  however,  that  setting  up  is  not
over-critical and the gating action is far more progressive.

Release:

Either a fast or slow release time may be selected depending on

the material being processed. Fast release is achieved with  the
switch out and Slow release with the switch depressed. Percussive
material with little or no reverb is generally treated using the fast
release setting, whereas material with slow decays or a significant
amount of added reverberation will usually respond better to the
longer release setting.

Summary of Contents for DL241

Page 1: ...NUAL CONTENTS SAFETY CONSIDERATIONS page 1 INTRODUCTION page 2 INSTALLATION page 3 CONTROL DESCRIPTIONS page 5 OPERATION page 8 IF A FAULT DEVELOPS page 10 CONTACTING DRAWMER page 10 TECHNICAL SPECIFI...

Page 2: ...umber copy of the original sales invoice and a detailed description of the problem Drawmer will not accept responsibility for loss or damage during transit This warranty is void if the product has bee...

Page 3: ...INPUT VOLTAGE SWITCH IS SET TO 230 VOLTS AC AND 63mA WHERE THE MAINS INPUT VOLTAGE IS 115 VOLTS AC ALL FUSES MUST COMPLY WITH IEC 127 2 THE FUSE BODY SIZE IS 20mm x 5mm CAUTION MAINS CABLE DO NOT ATTE...

Page 4: ...used The accepted way of dealing with this problem is to include in the compressor a separate expander section with its own threshold control so that a low level gating action may be applied to keep p...

Page 5: ...compatible with mono jacks The mono jack actually shorts the cold terminal to ground For the DL241 units fitted with XLR connectors unbalanced operation is achieved by shorting pin 3 of the XLR conne...

Page 6: ...voltage which is different to that as supplied the following procedure must be carried out see following diagram 1 Disconnect the unit from the mains 2 Using a number 1 size pozidrive screwdriver remo...

Page 7: ...ote because the expansion ratio varies with signal level it is possible to arrive at a situation where the red expansion LED may be illuminated when little or no perceived gain reduction is taking pla...

Page 8: ...he rate at which the compressor will respond to input signals that exceed the threshold level This may be set in the range 0 5mS to 100mS Release Sets the rate at which the system gain returns to norm...

Page 9: ...y fast acting enabling it to control any peaks without audible distortion If the output signal is so high as to cause the limiter to operate for more than 20mS the system gain is automatically reduced...

Page 10: ...ly by observing the gain reduction meter In general a maximum gain reduction of between 8dB and 12dB will be adequate If more gain reduction appears necessary consider applying a conservative degree o...

Page 11: ...mme dynamics it should be possible to obtain far more satisfactory results than are possible with conventional expanders By the same token do not assume that because the expander threshold LED flicker...

Page 12: ...original sales invoice and a detailed description of the problem Authorised returns should be prepaid and must be insured All Drawmer products are packaged in specially designed containers for protect...

Page 13: ...th Expander Off Wideband 22Hz 22KHz CCIR ARM IEC A Q Pk CCIR AV 90dB 95dB 95dB 97dB 84dB RMS 88dB 93dB 93dB 95dB 82dB DISTORTION 100Hz 1KHz 10KHz Unity Gain 4dBu input 0 03 0 02 0 03 14dBu input 10dB...

Page 14: ...DL241 OPERATORS MANUAL 12 BLOCK DIAGRAM...

Reviews: