background image

DL231 OPERATORS MANUAL

5

LED BAR DISPLAY is a dual function facility which measures output level (input level if

bypass is selected) or gain-reduction, selectable by the display
switch.

NB
i.

The VU meter and threshold controls are calibrated to show 0VU at +4dB

ii.

In the gain reduction mode, all the red LED’s are very slightly illuminated at all
times. This is quite normal and does not indicate a fault condition.

EXPANDER

THRESHOLD

(+10 to -40 dB) sets the point at which gain reduction takes place.
Signals above threshold pass un-attenuated unless compression
occurs..

RATIO

A three position switch selects ratios of 1:2, 1:5 or 1:20 provides
gating characteristics. Gating can be regarded as the opposite of
limiting.

ATTENUATION

(Attn) a three position switch sets the maximum attenuation of 10,
20 or 40dB.

FUNCTION

selects ‘side-chain listen’, normal (expander in operation) and off
(expander bypassed).

ATTACK

time is completely automatic. See introduction.

RELEASE

time is semi-automatic, matched to the compressor release and is
adjustable via the compressor release

VISUAL DISPLAY

is by means of three LED’s arranged in a horizontal ‘traffic light’
configuration. Green indicates zero expansion, whilst yellow shows
gain reduction of 50%, referring to the attenuated setting and red
100%.

STEREO LINK

couples the control circuits of both compressors to prevent image
shifting when treating stereo material on a final mix. The peak
limiters can also be used if desired but they remain independent.
Operational controls should be set the same on both channels when
linked.

SIDE-CHAIN EQ

may be applied to expanders and compressors via insert points at
the rear of the unit. Connection are via stereo jack ( Rind - send. Tip
- return)

Summary of Contents for DL231

Page 1: ...1 OPERATORS MANUAL CONTENTS SAFETY CONSIDERATIONS page 1 INTRODUCTION page 2 INSTALLATION page 3 CONTROL DESCRIPTIONS page 4 OPERATION page 6 TECHNICAL SPECIFICATION page 8 h DRAWMER ELECTRONICS LTD 1...

Page 2: ...number copy of the original sales invoice and a detailed description of the problem Drawmer will not accept responsibility for loss or damage during transit This warranty is void if the product has be...

Page 3: ...MAINS INPUT VOLTAGE SWITCH IS SET TO 230 VOLTS AC AND 125mA WHERE THE MAINS INPUT VOLTAGE IS 115 VOLTS AC ALL FUSES MUST COMPLY WITH IEC127 2 THE FUSE BODY SIZE IS 20mm x 5mm CAUTION MAINS CABLE DO NO...

Page 4: ...ase the versatility of such a unit by automating some of the more critical control functions The DL231 is a dual channel Expander Compressor Limiter combining ease of operation with flexible performan...

Page 5: ...ad try disconnecting the signal screen on the cables connecting the DL221 to the patchbay If such measures are necessary balanced operation is recommended S C INSERT The side chain insert point is con...

Page 6: ...for the compressor to recover from gain reduction Programme signals are complex so a complex release characteristic is required for optimum results Fast transients require a fast release time to avoid...

Page 7: ...h sets the maximum attenuation of 10 20 or 40dB FUNCTION selects side chain listen normal expander in operation and off expander bypassed ATTACK time is completely automatic See introduction RELEASE t...

Page 8: ...ereo link and set up as above making sure that all controls are the same for both channels GR displays will show the same readings except when excessive peak limiting occurs on either channel 6 If amb...

Page 9: ...djust the expander to obtain the required noise reduction NB The external filter will not affect the processed signal only the control circuitry Frequency Conscious Compression This can be achieved by...

Page 10: ...eshold 24dB to infinity ref 4dBm Ratio Variable 1 1 to 20 1 Attack 50 S to 5mS Release 50mS to 5 Sec Output Gain 20dB to 20dB EXPANDER Threshold 40dB to 10dB Ratio 1 1 1 2 1 20 Switchable Attenuation...