background image

6

production from all of your analogue to digital devices. The
analogue input is fed simultaneously to two seperately
controlled outputs both in AES/EBU, SPDIF and TOSLINK
formats enabling a backup copy to be made of the signal, as
well as solving any connectivity problems and allowing signal
distribution.

The Drawmer DMS-3 A2D2 has been meticulously designed
to faithfully, and transparently recreate your analogue signal
in digital in as simple and intuative method as possible. A
high quality Burr Brown input stage has been incorporated,
coupled with the AES Grade 1 digital converted outputs,
making the A2D2 perfect for recording, mastering and post-

CONTROL DESCRIPTION

INPUT LEVEL for 0dBfs
MODE

One switch toggles between 

Variable

 and 

Calibrated

 modes of input level gain.

VARIABLE

In situations where the input levels can vary from place to place, such as in outside broadcasts, or
live venues, a variable input level has been provided, with accurate individual left/right control, to
provide quick setup. This ranges from +28dBU to 0dBU.

CALIBRATED

In the studio, where input and output levels will be calibrated and under better control, a calibrated
input gain option has been provided, in the form of very accurate (24 turn) left/right potentiometers
ranging from +28dBU to 0dBU. These require a small screwdriver to operate and so once set are
less likely to be accidentally adjusted.

CHAPTER 2

Output Sample Rate

The A2D2 has dual independant stereo digital outputs at different selectable sample rates from 44.1kHz to 192kHz - so it is
possible to have a main output at 192kHz with another at 44.1kHz as a low resolution copy.

O/P 1

The outgoing sample rate for O/P1 of the DMS-3 can be set using the two sample rate switches on the top
row - the left moving down rate and the right moving up, with a corresponding LED being lit to show the
current sample rate. The DSM-3 generates six Ultra Low Jitter sample rates - 44.1k, 48k, 88.2k, 96k, 176.4k
and 192k, all stable to <1ppm, and in addition can also operate at the sample rate generated by an external
source. With the Leds set to EXT the sample rate is set by the Wordclock input (as located on the rear panel).
A lock LED is provided on the front and operates when the EXT clock signal is strong.
O/P 1 also sets the sample rate of the three wordclock outputs on the rear panel.

W/Length

The top switch provides either 16 Bit Dither or 24 Bit operation for O/P1.

O/P 2

The outgoing sample rate for O/P2 can be set using the two sample rate switches on the bottom row and
operates in exactly the same way as with O/P1. When on EXT the sample rate is set using the same
Wordclock input as with O/P1.

W/Length

The bottom switch provides either 16 Bit Dither or 24 Bit operation for O/P2.

Summary of Contents for A2D2 DMS-3

Page 1: ...Radio Frequencies Statement Chapter 1 Introduction Introduction Installation Power Connection Audio Connections Guide Chapter 2 Control Description Control Description Simple Setup Procedure Chapter 3 General Information If a fault develops Contacting Drawmer Specification Block Diagram 2 2 2 3 4 4 4 6 7 8 8 8 9 ...

Page 2: ... THE POSSIBILITY OF SUCH DAMAGES Some states and specific countries do not allow the exclusion of implied warranties or limitations on how long an implied warranty may last so the above limitations may not apply to you This warranty gives you specific legal rights You may have additional rights that vary from state to state and country to country For the USA FEDERAL COMMUNICATIONS COMMISSION RADIO...

Page 3: ...l and signal processing can be either analogue or digital software or hardware based At some point in the signal path a high quality Analogue to Digital converter is required which faithfully reproduces analogue signals in the digital domain Step up the Drawmer A2D2 The A2D2 is a stereo A D converter giving simultaneous dual stereo outputs at different selectable sample rates from 44 1kHz to 192kH...

Page 4: ...commended that a very good quality cable is used as the plastic conductors used in cheap cables can damage data Additionally performance is compromised over long lengths of cable as the signal strength weakens due to impurities in the conductive material therefore lengths of no longer than five metres are recommended unless using a signal booster Though the connectors are the same TOSLink and ADAT...

Page 5: ...5 SIMPLE CONNECTION GUIDE ...

Page 6: ...om 28dBU to 0dBU These require a small screwdriver to operate and so once set are less likely to be accidentally adjusted CHAPTER 2 Output Sample Rate The A2D2 has dual independant stereo digital outputs at different selectable sample rates from 44 1kHz to 192kHz so it is possible to have a main output at 192kHz with another at 44 1kHz as a low resolution copy O P 1 The outgoing sample rate for O ...

Page 7: ...at the meter is as close to 0dBfs as possible without drifting into overload to obtain the optimum output levels With your desired digital equipment connected to the any of the O P 1 digital outputs they work simultaneously and also connected to the wordclock outputs on the front panel set the top row O P1 of the Output Sample Rate to the desired rate and set the Bit Depth Where a digital backup o...

Page 8: ...ce your usage of this equipment Please address correspondence to Drawmer Technical Help line Coleman Street Parkgate Rotherham S62 6EL UK Alternatively contact us by E mail on tech drawmer com Further information on all Drawmer dealers Authorised service departments and other contact information can be obtained from our web pages on http www drawmer com A2D2 DMS 3 GENERAL INFORMATION CHAPTER 3 IF ...

Page 9: ...9 BLOCK DIAGRAM Ref 1v01 B 09 09 08 ...

Page 10: ...10 ...