background image

Drawell International Technology Limited

Web : www.drawell.com.cn

Tel: +86-023-63268643

Email : [email protected]

Thanks for purchasing the equipment, please carefully read the manual before operating.

I

Application

It’s widely used for drying, baking, melting wax and sterilization in factories, mines,

universities, scientific research and laboratories.

II. Technical Specifications

Note

:Performance parameters are tested under non-load conditions: ambient

temperature is 20°C, relative humidity is 50% RH.

III. Installation requirements

1

) The instrument should be placed in a constant temperature environment, and the

recommended temperature difference is 23 ± 5

;

Model

DW-LBI-

80

DW-LBI-150

DW-LBI-200

DW-LBI-250

DW-LBI-300

DW-LBI-400

Chamber Volume

80L

150L

200L

250L

300L

400L

Temperature Range

0~60

Display Resolution

0.1

Temperature Stability

±1

Temperature
Uniformity

±1

Timing Range

0~9999min

Power Rating

W

180

250

300

350

400

550

Refrigerant

R134a

Power Supply

220V , 50Hz

Continuous Operation

Long continuous operation

Chamber
Size(W×D×H)cm

40×37×55

45×42×85

45×45×100

48×49×107

52×50×117

58×54×127

Exterior
Size(W×D×H)cm

54×57×107

59×62×137

59×64×152

62×68×159

66×69×169

72×74×179

Package Size
(W×D×H)cm

70×73×126

75×78×156

75×80×171

78×84×178

82×85×188

88×90×198

Net/Gross Weight

kg

50/85

90/120

95/138

103/147

115/157

135/170

Summary of Contents for DW-LBI- 80

Page 1: ...International Technology Limited Chongqing Drawell Instrument Co Ltd Shanghai Drawell Scientific Instrument Co Ltd Chongqing Center Suite 2705 Building No 12 Shiyou Road No 1 Yuzhong District Chongqi...

Page 2: ...3 63268643 Email sales05 drawell com cn Contents I Application 3 II Technical Specifications 3 III Installation requirements 3 IV Operation Method 4 V Precautions 6 VI Failure handling methods 7 VII T...

Page 3: ...in a constant temperature environment and the recommended temperature difference is 23 5 Model DW LBI 80 DW LBI 150 DW LBI 200 DW LBI 250 DW LBI 300 DW LBI 400 Chamber Volume 80L 150L 200L 250L 300L...

Page 4: ...finished running it will continue to run at the breakpoint of the last program In the normal state the upper row will display the measured temperature and the lower row will display the temperature s...

Page 5: ...ill display the prompt and the lower row will display the parameter values see the attached table for details of each parameter After setting the parameter long press OK key for 5 seconds to exit the...

Page 6: ...d or alkali and other corrosive articles to wipe the surface The inside chamber can be cleaned regularly with dry cloth When the set temperature is lower than the room temperature the over temperature...

Page 7: ...st setting temperature The temperature controller is broken Change the temperature controller The cable is loose Tighten the cable Timing setting is incorrect Reset or cancel timing Big deviation of t...

Page 8: ...t work normally during warranty period our company is responsible for free repair or replacement of product parts Beyond the warranty we try our best to provide convenience for users IX Packing List W...

Page 9: ...tional Technology Limited Chongqing Drawell Instrument CO Ltd Add Suite 2705 Building No 12 Shiyou Road No 1 Yuzhong District Chongqing China Tel 0086 023 63268643 Shanghai Drawell Scientific Instrume...