Main body structure

Structure characteristics

1.

The main body of the container to our product is made of high—quality stainless

steel with one portion of Gr, eighteen of Ni, nine of Ti. Our product is not only

acid—proof,alkali--proof,but also safe and durable to consume, its life is three

times longer than aluminum metal alloy product.

2.

Our product heated up by immersion electric heating tube, consumes little power,

while temperature goes up quickly.

3.

Vary heating method available, such as liquefied gas, coal gas, coal gas

stove,firewood,etc.

4.

The safety valve can release over-high pressure automatically when the steam

pressure exceeds 0.165MPa to insure the safety.

5.

The pressure gauge is designed to have double scales, with two types

of reading to show pressure and temperature clearly.

1

1. Safety valve

2. Handle

3. Pressure gauge

4. Steam release valve

5. Container lid

6. Silicone seal

7. Butterfly nut

8. Bolt

9. Container

10. Sterilization chamber

11. Sieve plate

12. Electric heating tube

13. Water discharge cock

14. Set key

15. Led digital display screen

16. Increase/decrease key

17. Start/Stop key

18. Buzzer

19. Wrench

20. Power cable

Summary of Contents for DW-280D

Page 1: ...Model DW 280D digital 18L 24L 30L PORTABLE STEAM STERILIZER USER S MANUAL...

Page 2: ...The equipment should be keep clean and dry in ordinary times pour water out of container when finishing using to help to prolong the life of the sterilization machine 5 Check the sealing ring to find...

Page 3: ...method available such as liquefied gas coal gas coal gas stove firewood etc 4 The safety valve can release over high pressure automatically when the steam pressure exceeds 0 165MPa to insure the safet...

Page 4: ...st 4 To be sure the power source voltage is in accordance with the demand of the apparatus and dependable earth wire required 5 Don t locate the apparatus near inflammable gas sources it should be ins...

Page 5: ...row digital display of time code ST and the time values click the Change button adjusted to required sterilization temperature ST is 0 the controller cancel timer function start time set is the last...

Page 6: ...ill not get a good sterilization effect 4 Every time after the disinfection and sterilization must turn off the power switch 5 Sterilization of the solution the solution should be poured into the high...

Page 7: ...sted at least once a year If the hand of the gauge cannot return to 0 position it should be professionally repaired or replaced otherwise the sterilization effect and safety will be affected Different...

Page 8: ...DW 280D Digital Circuit Diagram 1 K Control switch 2 C Control panel 3 L Lever sensor 4 T Temperature sensor 5 M Solid state relay 6 R Electric heating tube...

Reviews: