background image

Section 10 -

 Case Length Dimensions

Section 12 -

 Mounting Bracket Dimensions

Section 11 -

 Case Width Dimensions

5

/

8

 (16mm)

3

/

8

(41mm)

12 

3

/

16

” (

310mm)

10 

15

/

16

” 

(278mm)

5

/

8

” 

(86mm)

For minumum length of ceiling cutout: subtract 38mm from case length 

(measured from outer edge of flanges)

For minimum width of cutout 

(front to back)

: see case width dimensions below. 

**Leveling brackets are used to level the case and should NOT be used to support the weight of the unit.  

The leveling brackets are riveted to the side of the case and remains stationary. Hardware used for leveling provided by others.

Leveling brackets are not adjustable.

14 

11

/

16

(373mm)

3

1

/

16

(77mm)

9

/

16

(65mm)

3

/

8

(187mm)

½”

(13mm)

10 

3

/

8

” 

(264mm)

9¾” 

(248mm)

11” 

(274mm)

14 

1

/

16

(357mm)

7

/

16

(11mm)

2”

(51mm)

12 

3

/

16

” 

(310mm)

7

/

8

(22mm)

5

/

8

(16mm)

18” 

(457mm)

2”

(51mm)

*L = Varies

L*

¾”

(19mm)

CASE LENGTH

Series E

Viewing Surface

18” 

(457mm)

2”

(51mm)

*L = Varies

L*

¾”

(19mm)

CASE LENGTH

Series E

Viewing Surface

18” 

(457mm)

2”

(51mm)

*L = Varies

L*

¾”

(19mm)

CASE LENGTH

Series E

Viewing Surface

Series V

Viewing Surface

ULTIMATE

ACCESS XL

For minumum length of ceiling cutout:

 

subtract 1½" (38mm) 

from case length (measured from outer edge of flanges). 

For minimum width of cutout (front to back):

 see case width dimensions below.

Standard Motor Wiring is on the 

AUDIENCE LEFT END 

of Screen Case.

14 

11

/

16

(373mm)

3

1

/

16

(77mm)

9

/

16

(65mm)

3

/

8

(187mm)

½”

(13mm)

10 

3

/

8

” 

(264mm)

9¾” 

(248mm)

11” 

(274mm)

14 

1

/

16

(357mm)

7

/

16

(11mm)

2”

(51mm)

12 

3

/

16

” 

(310mm)

7

/

8

(22mm)

5

/

8

(16mm)

18” 

(457mm)

2”

(51mm)

*L = Varies

L*

¾”

(19mm)

CASE LENGTH

Series E

Viewing Surface

18” 

(457mm)

2”

(51mm)

*L = Varies

L*

¾”

(19mm)

CASE LENGTH

Series E

Viewing Surface

18” 

(457mm)

2”

(51mm)

*L = Varies

L*

¾”

(19mm)

CASE LENGTH

Series E

Viewing Surface

Series V

Viewing Surface

ULTIMATE

ACCESS XL

For minumum length of ceiling cutout:

 

subtract 1½" (38mm) 

from case length (measured from outer edge of flanges). 

For minimum width of cutout (front to back):

 see case width dimensions below.

Standard Motor Wiring is on the 

AUDIENCE LEFT END 

of Screen Case.

page 6 of 7

Ultimate Access XL E & V 

Electric Projection Screen

Summary of Contents for Ultimate Access XL V

Page 1: ...ecommended prior to painting If not removed slot on bottom of case should be shielded to protect viewing surface from paint splatters overspray If you have any difficulties installing or servicing your Ultimate Access XL Screen call your dealer or Draper Inc E Free Hanging Viewing Surface V Flexible Vinyl Viewing Surface CAUTION Read and understand all warnings p 2 before beginning installation Pl...

Page 2: ...nstalled calibrated and tested 14 Unit may need to comply with local state or district rules and regulations in particular when installed in schools All applicable rules and regulations should be reviewed before installation and use 15 Failure to precisely follow installation guidelines invalidates all warranties 16 Custom products installations may not be reflected in this manual Call Draper Inc ...

Page 3: ...dler pin goes through idler bracket Reinstall washer and retaining clip Caution Failure to replace washer and retaining clip could result in separation of roller from brackets 5 Center roller fabric assembly by sliding mounting brackets left or right 6 Securely tighten set screws on roller mounting brackets 7 Connect electrical plug from motor to mating socket on junction box 8 Attach center door ...

Page 4: ...switches When off switches will not operate screen Key may be removed from switch in either on or off position Three position key switch permits the screen to be operated directly by key Requires screen operator to have a key RS232 ETHERNET Serial communication and network communication optionally available Section 8 Electrical Connections 1 Screen operates on 110 120V 60 Hz 1 1 amp current draw 2...

Page 5: ...o shut off manually while testing Screen may be damaged by lowering it too far and exposing roller Motor must be installed so limit switches are pointed down Section 8 1 2 Up Limit Adjustment If Screen Raises Too High 1 Lower screen surface approx 1 30 cm below desired setting and turn off 2 Turn UP II limit screw clockwise 3 screw turns 1 2 roller revolution 3 Test by advancing screen up 4 Repeat...

Page 6: ...18 457mm 2 51mm L Varies L 19mm CASE LENGTH Series E Viewing Surface 18 457mm 2 51mm L Varies L 19mm CASE LENGTH Series E Viewing Surface 18 457mm 2 51mm L Varies L 19mm CASE LENGTH Series E Viewing Surface Series V Viewing Surface ACCESS XL For minumum length of ceiling cutout subtract 1 38mm from case length measured from outer edge of flanges For minimum width of cutout front to back see case w...

Page 7: ...n Factory wiring Low voltage wiring by others IR Eye Input Low Voltage Trigger 4 28 VDC RS232 485 Inputs Outputs Receiver Button 3 Button Wall Switch DOWN Black COM White UP Red Wall Switch Electrically Straight Data Cable to more LVC IV modules FUSE 3 15 AMP 250 VAC 5x20mm To 110 120 VAC Line Red to screen directional Brown to screen directional Yellow to 110V 120V AC Hot Black to 110V 120V AC Ho...

Reviews: