Please Note:

 Draper’s Tab-Tensioning System is factory-set, and under normal 

circumstances will not require field adjustment.  

If wrinkles are observed, however, follow the adjustment procedure  

shown in Figure 8.

Section 7 -

 Tab-Tension Adjustment Procedure

Section 6 -

 Operation

 Caution:

 When operating for the first time, cycle unit down and up several times to confirm satisfactory operation. Be prepared to cut POWER if necessary. 

• 

110-120V SINGLE STATION CONTROL

 - 

3-position UP-OFF-DOWN switch permits operation to be stopped at any point. Factory adjusted limit switches 

automatically stop screen when fully down or fully up.

•  110-120V MULTIPLE STATION CONTROL - 

Switches are similar in appearance to 110-120V Single Station Control. Screen stops when switch is released and 

may be restarted in either direction. Factory adjusted limit switches stop screen automatically when fully up or fully down.

•  24V CONTROL - 

3-button UP-STOP-DOWN switches stop at any point desired, operate in any sequence. Factory adjusted limit switches automatically stop 

screen when fully up or fully down. Installer should incorporate an all-pole disconnect in fixed wiring available with RF or IR remote.

•  KEY OPERATED SWITCHING - 

Two key-operated switches optionally available with this unit: 

•  Key-operated power supply switch 

controls power to screen and switches. When “off”, switches will not operate screen. Key may be removed from 

switch in either "on" or "off" position. 

•  Three-position key switch

 permits the screen to be operated directly by key. Requires screen operator to have a key.

•  RS232 / ETHERNET - 

Serial communication and network communication optionally available.

Section 8 -

 Electrical Connections

1. 

Screen operates on 110-120V, 60 Hz., 1.1 amp current draw.

2. 

Junction box is located just above the bottom access panel at the left end of the screen. 

3. 

Open the access panel/trap door for access to the junction box cover. 

(See bottom access panel/trap door opening and closing instructions below)

4. 

Remove two 

(2)

 hex head screws that secure the cover to the junction box to expose the red, black, and white pigtail leads and the green ground wire per wiring 

diagram 

(Page 7)

.

5. 

If optional low voltage control or video interface control is specified and factory installed, please refer to wiring diagram 

(Page 7)

.

6. 

Screen is shipped with internal wiring complete and control switch

(es)

 fully boxed. Wire to connect screen to switch

(es)

 and switch

(es)

 to power supply should 

be furnished by installer. Connections should be made in accordance with attached wiring diagram, and wiring should comply with national and local electrical 

codes.

7. 

All operating switches should be “off” before power is connected.

PUSH & TURN

CLOCKWISE

to INCREASE TENSION

PUSH & TURN

COUNTER-CLOCKWISE

to RELEASE TENSION

END OF 
DOWEL

END OF 
DOWEL

Figure 8

page 4 of 7

Ultimate Access XL E & V 

Electric Projection Screen

Summary of Contents for Ultimate Access XL V

Page 1: ...ecommended prior to painting If not removed slot on bottom of case should be shielded to protect viewing surface from paint splatters overspray If you have any difficulties installing or servicing your Ultimate Access XL Screen call your dealer or Draper Inc E Free Hanging Viewing Surface V Flexible Vinyl Viewing Surface CAUTION Read and understand all warnings p 2 before beginning installation Pl...

Page 2: ...nstalled calibrated and tested 14 Unit may need to comply with local state or district rules and regulations in particular when installed in schools All applicable rules and regulations should be reviewed before installation and use 15 Failure to precisely follow installation guidelines invalidates all warranties 16 Custom products installations may not be reflected in this manual Call Draper Inc ...

Page 3: ...dler pin goes through idler bracket Reinstall washer and retaining clip Caution Failure to replace washer and retaining clip could result in separation of roller from brackets 5 Center roller fabric assembly by sliding mounting brackets left or right 6 Securely tighten set screws on roller mounting brackets 7 Connect electrical plug from motor to mating socket on junction box 8 Attach center door ...

Page 4: ...switches When off switches will not operate screen Key may be removed from switch in either on or off position Three position key switch permits the screen to be operated directly by key Requires screen operator to have a key RS232 ETHERNET Serial communication and network communication optionally available Section 8 Electrical Connections 1 Screen operates on 110 120V 60 Hz 1 1 amp current draw 2...

Page 5: ...o shut off manually while testing Screen may be damaged by lowering it too far and exposing roller Motor must be installed so limit switches are pointed down Section 8 1 2 Up Limit Adjustment If Screen Raises Too High 1 Lower screen surface approx 1 30 cm below desired setting and turn off 2 Turn UP II limit screw clockwise 3 screw turns 1 2 roller revolution 3 Test by advancing screen up 4 Repeat...

Page 6: ...18 457mm 2 51mm L Varies L 19mm CASE LENGTH Series E Viewing Surface 18 457mm 2 51mm L Varies L 19mm CASE LENGTH Series E Viewing Surface 18 457mm 2 51mm L Varies L 19mm CASE LENGTH Series E Viewing Surface Series V Viewing Surface ACCESS XL For minumum length of ceiling cutout subtract 1 38mm from case length measured from outer edge of flanges For minimum width of cutout front to back see case w...

Page 7: ...n Factory wiring Low voltage wiring by others IR Eye Input Low Voltage Trigger 4 28 VDC RS232 485 Inputs Outputs Receiver Button 3 Button Wall Switch DOWN Black COM White UP Red Wall Switch Electrically Straight Data Cable to more LVC IV modules FUSE 3 15 AMP 250 VAC 5x20mm To 110 120 VAC Line Red to screen directional Brown to screen directional Yellow to 110V 120V AC Hot Black to 110V 120V AC Ho...

Reviews: