Silhouette E & V
Page 5 of 5
RS232/485 Inputs/Outputs
Receiver
Button
Low Voltage Trigger
4-28 VDC
IR Eye Input
3 BUTTON WALL SWITCH
DOWN -
BLACK
COM -
WHITE
UP -
RED
Wall Switch
To 110-120
VAC LINE
RED -
to screen
(directional)
BROWN -
to screen
(directional)
YELLOW -
to 110V AC-Hot
BLACK -
to 110V AC-Hot
WHITE -
Common to screen & 110V AC Neutral
GREEN/YELLOW
(Ground)
WHITE
(Common)
RED
(Up)
BLACK
(Down)
INTERNAL SCREEN WIRING
GREEN/YELLOW
(Motor Ground)
Electrically Straight
Data Cable to more
LVC-IV modules*
N
L1
GND
Location of key
operated 0n-off
switch if furnished.
Signal Light
External LVC-IV -
Single or Multiple
Projection Screen 120V Wiring Diagram
Receiver
Button
3 BUTTON WALL SWITCH
DOWN -
BLACK
COM -
WHITE
UP -
RED
Wall Switch
To 110-120
VAC LINE
RED -
to screen
(directional)
BROWN -
to screen
(directional)
YELLOW -
to 110V AC-Hot
BLACK -
to 110V AC-Hot
WHITE -
Common to screen & 110 AC Neutral
GREEN/YELLOW
(Ground)
WHITE
(Common)
BLACK
(Up)
RED
(Down)
INTERNAL SCREEN WIRING
GREEN/YELLOW
(Motor Ground)
Electrically Straight
Data Cable to more
LVC-IV modules*
N
L1
GND
Location of key
operated 0n-off
switch if furnished.
Signal Light
External LVC-IV -
Single or Multiple
Ambassador and Rolleramic 120V Wiring Diagram
Dashed wiring by electrician
Low voltage wiring by others
Dashed wiring by electrician
Low voltage wiring by others
*A maximum of six (6)
LVC-IV modules can be
linked together.
*A maximum of six (6)
LVC-IV modules can be
linked together.
RS232/485 Inputs/Outputs
Low Voltage Trigger
4-28 VDC
IR Eye Input
ILT Switch-to-Motor—Dry Contacts or Data Cable connection
Please Note:
This Splitter/
Jack is located inside the
junction box of your screen.
Back of wall switch.
Please Note:
Although both
Dry Contact and Data Cable
connections are shown, you
should only use one connec-
tion type per motor.
Data Cables to switches or
to additional motors can
be plugged into any of the
three open jacks. If this is a
"Case First, Screen Later"
installation, plug the motor
cable into the jack indicated
in the drawing.
Please Note: 5V DC must be
connected to be able to set
limits using the wall switch.
INSERT MOTOR DATA
CABLE HERE