Wiring Diagrams

Do not wire motorized units in parallel without written consent from Draper.

Wiring Diagrams Standard Motor)

Single Station Control 

Internal Screen Wiring

White (Common)

Black (Down)

Red (Up)

Green/Yellow (Ground)

Dashed wiring  
by electrician 

Control 
switch 

Single gang box by others 
Min. 4" x 2

 

1

/

8

" x 1

 

7

/

8

" deep 

Blue 

Black 

Red 

Location of key 
operated on-off  
switch if furnished 

To 110-120V Line 

Multiple Station Control 

Internal Screen Wiring

White (Common)

Black (Down)

Red (Up)

Green/Yellow (Ground)

Dashed wiring  
by electrician 

Red 

Red 

Black 

Blue 

Blue 

Cap off with wire  
nut and tape 

Black 

Red 

Blue 

Black 

Single gang box by others 
Min. 4" x 2

 

1

/

8

" x 1

 

7

/

8

" deep. 

3 shown. More or less equally 
feasible. 

Location of key 
operated on-off  
switch if furnished 

To 110-120V Line 

External Two-Way Serial Communication (RS232) with MC1

3 Button W

a

ll Switch 

DO

WN - Blac

k

COM - White

UP - Red

White-Common to screen & 110-120V A

C

 Neutr

al

Red-to screen (directional)

Bro

wn-to screen (directional)

Ye

llo

w

-to 110-120V A

C

-Hot

Blac

k-to 110-120V A

C-Hot

Green-Ground

Ey

e P

o

rt

 fo

r IR Ey

e,

 RF Receiv

e

r or LED

W

a

ll Switch.

 F

o

r more than one of 

these

, a splitter is required.

Au

x

 P

o

rt

 

fo

r connecting additional L

VC-III 

modules (up to six total can be link

ed-

connect from A

ux to Ey

e).

Dashed wir

ing b

y electr

ician

Lo

w v

oltage wir

ing b

y others

White (Common)

Red (Up)

Blac

k (Do

w

n)

Green (Ground)

Location of k

ey

oper

ated on-off 

sw

itch if fur

nished

To

110-120V

Line

Inter

nal Screen Wir

ing

ST

OP

Control 

Switches

24v DC

ST

OP

RS232 Data FROM Control System 

RS232 Data TO Control System 

Signal Ground & Manual Switch Common 

Manual Switch Down 

Manual Switch Up 

White-Common to screen & 110-120V AC Neutral 
Red-to Screen (directional) 
Brown-to Screen (directional) 
Black-Hot to 110-120V AC 
Green/Yellow-Ground 

Fuse 

Program LED 

Eye Port for IR Eye. For RF Receiver or LED 
Wall Switch, a Splitter and a Power Supply 
is required. Plug RF Receiver or LED Wall  
Switch and Power Supply into splitter, then  
run cable from Splitter to MC1 Eye Port. 

Low Voltage Wiring by others 

AC Wiring by electrician 

MC1 

White (Common)
Red (Up)
Black (Down)
Green/Yellow (Gnd)

Internal Screen Wiring 
 

Location of key 
operated on-off  
switch if furnished 

To 

110-120V 

Line 

STOP 

Control  
Switches 
24v DC 

STOP 

External Low Voltage and Remote Control

Please Note: Do not wire motors in parallel.

Internal Screen Wiring

White (Neutral)

Black

Green (Ground)

Dashed wiring 
by electrician

To 110-120V Line

Wall Switch

or RF

Receiver

Radio Technology

110-120V Motor

 CAUTION: Wall switches 

provided with these screens are 
interior switches, and should 
not be installed outdoors.

Summary of Contents for Nocturne

Page 1: ...t then remove ad ditional screws holding fascia onto back top and rotate fascia up and off of unit see Fig 2 Remove screen assembly from screen case If motorized remove motor retaining clips Pull the screen assembly away from the operator end This will depress the spring loaded pin on the non operator end Then you can rotate screen assembly out of the screen case Fig 4 Figure 4 Motorized Crank Dri...

Page 2: ...oper back push button Lower screen to desired down stop position Set lower limit by depressing and releasing the proper front push button Screw Type Limits Determine which direction of travel corresponds with arrows on motor Operate screen to desired down stop position Set limit by turning the proper socket toward the to lower the limit and to raise it Operate screen to desired up stopping positio...

Page 3: ...Aux Port for connecting additional LVC III modules up to six total can be linked connect from Aux to Eye Dashed wiring by electrician Low voltage wiring by others White Common Red Up Black Down Green Ground Location of key operated on off switch if furnished To 110 120V Line Internal Screen Wiring STOP Control Switches 24v DC STOP RS232 Data FROM Control System RS232 Data TO Control System Signal ...

Page 4: ... you have The limits must also be set Here are the initial programming instructions Connect power to motor Select the transmitter channel to which you plan to learn the motor Press and hold the UP and DOWN buttons at the same time until the motor jogs then release Check the motor run direction by press either the UP or DOWN buttons This is important because if you do step 3 without doing this step...

Reviews: