![Draper Foundation Installation Manual Download Page 16](http://html.mh-extra.com/html/draper/foundation/foundation_installation-manual_2528080016.webp)
page 16 of 32
Foundation
™
for LED Panels
Section 6 -
Adjusting and Aligning Horizontal Rails
1.
Position three
(3)
Plum Alignment Pins on each horizontal rail ensuring one is at the far left, center and far right.
2.
Using a 5mm Hex Wrench, loosen the four
(4)
locking screws on the top and bottom of each of the four
(4)
outer wall mounting brackets.
3.
Shine a laser level parallel to the wall with the laser intersecting the plum alignment pins.
4.
Using a 3mm Hex Wrench, turn the two
(2)
adjustment set screws on each wall mounting bracket to position the Alignment Notch with the laser line
(Please Note: when setting the plumb adjustment, the face of the horizontal rail must remain plump and not twisted)
.
5.
Once the Laser Line and all Alignment Pins are aligned, tighten the four
(4)
locking screws on the top and bottom each of the outer mounting bracket.
SIDE
VIEW
TOP VIEW -
CONVEX WALL
Laser Line
Laser Line
TOP VIEW -
CONCAVE WALL
SIDE
VIEW
Laser Line
Laser Line
Loosen
Adjustment
Screws
Loosen
Adjustment
Screws
Alignment
Notch
LASER
LINE
Before
Adjustement
Tighten
Adjustment
Screws
Tighten
Adjustment
Screws
3mm Hex
Wrench
LASER
LINE
After
Adjustement
After
Adjustement
Alignment
Notch