background image

SkyLight 3 Installation Instructions

 6 

of

 6

(765) 987-7999

www.draperinc.com

2”

Center Roller Diameter 1½”

3¼”

10¼”

Fully Open

4½”

6

3

/

8

Side View

Top View - Open Position

3¼” 
Hem 
Bar 
Width 

Stay and Seam Placement 

(if Required)

Shade Length

Shade 

Width

Fabr

ic 

Width = Shade 

Width - 4”

This Side 

Faces the Window

Single Low Voltage Control 

Internal Shade Wiring
White (Neutral)
Black
Green (Ground)

Dashed wiring  
by electrician 

To 110-120V Line 

Multiple Low Voltage Controls 

Internal Shade Wiring
White (Neutral)
Black
Green (Ground)

Dashed wiring  
by electrician 

To 110-120V Line 

Wall Switch, 

RF or IR 

Receiver, 

or integrated 

control system 

Wall Switches, 

RF or IR 

Receivers, 

or integrated 

control systems 

Data Cable 

Data 
Cables 

 

Optional 
splitter 

110-120V Sonesse ILT 50 Shade Wiring Diagram

SkyLight 3 Dimensions

Summary of Contents for FlexShade SkyLight 3

Page 1: ...ld be tested and limits set using test cord before electrician wires shade 12 Before connecting switches controls or electrical make sure power is off Wiring indicated in diagram by dashed lines must be completed by an electrician 13 Do not wire motors in parallel without written permission from Draper 14 It is the installer s responsibility to make sure appropriate fasteners are used for mounting...

Page 2: ...th Center Tab flush with window B b w f Figure 3 Upper Section Lower Section Installing End Pulley Brackets Part One Insert Relieving Roller Anchor Before inserting the Relieving Roller Anchor confirm measurements on the card provided with the shade The length of the shade will determine whether a Relieving Roller is required and the Relieving Roller Anchor orientation Shade shorter than 122 Shade...

Page 3: ... Motor Ring 4 Attach the Idler Mounting Bracket WARNING The following procedure REQUIRES at least two 2 installers to preform safely Part Two Motor Cable Routing see fig 8 1 Feed Motor Cable through the Cable Exit hole See Cable Exit Step 1 2 Route the Motor Cable toward the back of the Motor Mounting Bracket as shown in Fig 8 This will ensure that the Motor Cable does not interfere with the shade...

Page 4: ...Hem Bar Slot toward the Side Channel until it stops This Draw Cable is now properly tensioned 3 Repeat on the opposite side Shade Fabric attached to Hem Bar Hem Bar in Side Channel Tensioning Pulley Draw Cables Shade Fabric attached to Hem Bar Over Tensioning Pulley Draw Cables one on each side End Bracket Pulleys End Bracket Pulleys Sticker Hem Bar in Side Channel See Attaching Cable to Hembar Be...

Page 5: ...mply with national and local electrical codes DO NOT wire motors in parallel without written permission from Draper All operating switches should be off before power is connected Please Note For low voltage wiring requirements Draper recommends consulting with a professional low voltage electrical contractor It is very important that shielded and stranded CAT 5 cable be used to prevent any electri...

Page 6: ...w Single Low Voltage Control Internal Shade Wiring White Neutral Black Green Ground Dashed wiring by electrician To 110 120V Line Multiple Low Voltage Controls Internal Shade Wiring White Neutral Black Green Ground Dashed wiring by electrician To 110 120V Line Wall Switch RF or IR Receiver or integrated control system Wall Switches RF or IR Receivers or integrated control systems Data Cable Data C...