background image

SkyLight 3 Installation Instructions

 3 

of

 6

(765) 987-7999

www.draperinc.com

Part Three: Installing Roller Fabric Assembly -

 (2 installers REQUIRED)

 

(1) 

 Lift the entire

 Roller Assembly up near the Motor Mounting Brackets and  

      insert the 

Hem Bar Rollers into the Side Channels (see Fig. 9).  

      Be sure to continuously pull the excess 

Motor Cable through the Cable Exit.   

 

(2) 

 With the 

Hem Bar inserted into both of the Side Channels, lift the Roller  

     Assembly up until the Lower Sections of the Motor Mounting Brackets  
    (attached to the ends of the 

Roller Assembly) are completely engaged with  

  the 

Upper Sections (mounted to the skylight frame).   

 

(3) 

 Re-tighten the four (4) screws (2 per bracket) using a Hex Wrench. 

Installing Roller/Fabric Assembly

Part One: Attaching Lower Sections of Motor Bracket (see fig. 7)

 

(1)

 Remove the 

Motor Ring from the Motor on the end of the Roller Assembly.

 
 

(2)

 Feed the 

Motor Cable through the Operator side of the Motor Mounting  

  Bracket. 
 
 

(3)

 Attach the 

Operator Mounting Bracket to Motor and secure with Motor Ring.

 
 

(4)

 Attach the 

Idler Mounting Bracket.

WARNING : 

The following procedure REQUIRES at least two (2)  

     

 

  installers to preform safely.

Part Two: Motor Cable Routing (see fig. 8) 

 

(1)

 Feed 

Motor Cable through the Cable Exit hole (See Cable Exit Step 

(1)

). 

 
 

(2) 

Route the 

Motor Cable toward the back of the Motor Mounting Bracket  

    as shown in Fig. 8. This will ensure that the 

Motor Cable does not interfere  

    with the shade while in operation.

C

 Feed Motor Cable         

     through the Operator      
     side of the Motor  

      

     Mounting Bracket

B

 Remove  

 

     Motor Ring

D

 Attach Bracket to Motor 

     and Secure with Motor Ring

E

 Attach Idler Bracket     

Hem Bar

Roller 

Assembly

Idler End

Roller 

Assembly

Operator End

Figure 

(7)

C

 Route Motor Cable

     toward the back of 
     the bracket as shown

B

 Feed Motor Cable

     through the Cable      
     Exit hole

Roller 

Assembly

(Operator End)

Figure 

(8)

WINDOW 

FRAME

WIDTH

B

 Insert Hem Bar 

     Rollers into 

     Side Channels

INSERT ROLLERS

HEM BA

R

HEM 

BAR

Figure 

(9)

Roller

Assemb

ly

HEM 

BAR

C

 With the Hem Bar inserted into

     the both of the Side Channels, 
     Lift the Roller Assembly up until the  
     Lower Sections of the Motor 
     Mounting Brackets are engaged with  
     the Upper Sections.

D

 Re-tighten the four (4) 

     screws (2 per bracket) 
     using a hex wrench.

Figure 

(10)

Summary of Contents for FlexShade SkyLight 3

Page 1: ...ld be tested and limits set using test cord before electrician wires shade 12 Before connecting switches controls or electrical make sure power is off Wiring indicated in diagram by dashed lines must be completed by an electrician 13 Do not wire motors in parallel without written permission from Draper 14 It is the installer s responsibility to make sure appropriate fasteners are used for mounting...

Page 2: ...th Center Tab flush with window B b w f Figure 3 Upper Section Lower Section Installing End Pulley Brackets Part One Insert Relieving Roller Anchor Before inserting the Relieving Roller Anchor confirm measurements on the card provided with the shade The length of the shade will determine whether a Relieving Roller is required and the Relieving Roller Anchor orientation Shade shorter than 122 Shade...

Page 3: ... Motor Ring 4 Attach the Idler Mounting Bracket WARNING The following procedure REQUIRES at least two 2 installers to preform safely Part Two Motor Cable Routing see fig 8 1 Feed Motor Cable through the Cable Exit hole See Cable Exit Step 1 2 Route the Motor Cable toward the back of the Motor Mounting Bracket as shown in Fig 8 This will ensure that the Motor Cable does not interfere with the shade...

Page 4: ...Hem Bar Slot toward the Side Channel until it stops This Draw Cable is now properly tensioned 3 Repeat on the opposite side Shade Fabric attached to Hem Bar Hem Bar in Side Channel Tensioning Pulley Draw Cables Shade Fabric attached to Hem Bar Over Tensioning Pulley Draw Cables one on each side End Bracket Pulleys End Bracket Pulleys Sticker Hem Bar in Side Channel See Attaching Cable to Hembar Be...

Page 5: ...mply with national and local electrical codes DO NOT wire motors in parallel without written permission from Draper All operating switches should be off before power is connected Please Note For low voltage wiring requirements Draper recommends consulting with a professional low voltage electrical contractor It is very important that shielded and stranded CAT 5 cable be used to prevent any electri...

Page 6: ...w Single Low Voltage Control Internal Shade Wiring White Neutral Black Green Ground Dashed wiring by electrician To 110 120V Line Multiple Low Voltage Controls Internal Shade Wiring White Neutral Black Green Ground Dashed wiring by electrician To 110 120V Line Wall Switch RF or IR Receiver or integrated control system Wall Switches RF or IR Receivers or integrated control systems Data Cable Data C...