– 11 –
(D)
Display
Used to display the values of each parameter.
(E)
Data save button
Used for save welding data, which can store ten
different sets of welding data.
(F)
Parameter adjusting knob
Adjust parameters.
(G)
Load button
Retrieve the stored welding parameters
(H)
Welding mode selection button
Hold for three seconds in the Argon welding, then
release the convertible arc welding.
(I)
Waveform selection button
Square wave, sine wave and triangle wave can be
selected.
(J)
AC and DC selection button
DC, AC function selection.
(K)
Pulse function selection
Choose the pulse and compound pulse function, and
the compound pulse function can only be used in the
state of AC
(L)
High voltage indicating light
no-load voltage indicator light
(M)
Alarm light
Welding machine overheat, over current alarm light.
7.7 FUNCTION PARAMETERS
Function:
Description:
Adjust Range:
Default value:
Pre-flow
The time of gas prior to
welding
0~10 S
0.1 S
Hot start
Hot start current
5~200A
100A
Arc-start current
The preset starting
current is adjusted when
arc closing is controlled
5~200A
40 A
Slope up
When arc closing control
is adopted, the rising time
from arc starting current
to welding current can be
adjusted
0~20 S
5 S
Spot welding
The welding time in the
spot welding functional
state
0~10 S
3 S
Base current
When pulse mode is
adopted, the low current
of the pulse is adjusted
5~200A
10 A
Peak current/welding
current
Adjust welding current or
pulse peak current
5~200A
150 A
Duty ratio
Adjust the ratio of peak
current to pulse period
when pulse mode is
adopted
10~90 %
50 %
Summary of Contents for Expert 70052