Draper Access MultiView Series Installation & Operating Instructions Download Page 2

Motorized Roller/Fabric Installation

The bottom access panel must be removed first. The Access/MultiView has 
two roller/fabric assemblies. The one equipped with a complete projection 
screen fabric is installed first, higher in the brackets, and connects to the 
left-hand junction box. The second roller has black masking strips at the sides 
and no fabric in the middle: it installs lower in the brackets and connects to the 
right-hand junction box.
The motor end mounting brackets have steel mounting rings with prongs that
engage with motor head.
To engage the motor end bracket flange above the two channels in the top of 
the screen housing, rotate the bracket approximately 45° counterclockwise 
to allow the top surface of the motor bracket to rest flat against the top inside 
of the housing. Rotating the bracket clockwise until it is engaged with the 
channels, slide it along the length of the housing toward the electrical junction 
box at left end of case.

Engage the idler end bracket (rectangular mounting pad) in the same manner 
as the motor end bracket and slide it toward the opposite end of the screen 
housing. Do not tighten the set screws on this bracket until the roller/fabric 
assembly is installed.
Locate the viewing surface roller/fabric assembly and remove the retaining 
clip and flat steel washer from the idler end pin.

(NOTE: This will require two people to perform safely.)

 Raise the viewing 

surface roller/fabric assembly up into the screen housing and en-gage the 
head of the motor completely into the motor mounting bracket. The steel clip 
on the motor mounting ring must snap into the groove on the motor. Once this 
is done the clip must be manually pulled down away from the mounting ring to 
disengage motor. Make sure the limit switch adjustment knobs are visible from 
bottom of housing. 
While supporting the idler end of the roller, slide the idler end mounting 
bracket toward the roller. Insert the roller pin into the nylon bushing on the 
idler end mounting bracket.
The roller idler pin needs to go through the idler bracket far enough to allow 
the steel washer and retaining clip to be reinstalled on the pin. Failure to 
replace the washer and retaining clip as shown could result in the separation 
of the roller from the brackets.
The fabric/roller assembly and brackets will need to be moved left or right 
until centered in case. Tighten two set screws on each roller mounting bracket 
using 

1

/

8

" hex key.

Locate the masking roller assembly and remove the retaining clip from motor 
stud and remove retaining clip and washer from idler pin.
Raise masking roller up into screen housing making sure motor is on the 
right (as viewed by audience). Engage the motor stud inside square bushing. 
Engage the idler pin all the way through the round bushing on left roller 
mounting bracket. Place washer over pin and fasten retaining clip in the 
groove of idler pin.

220V Access MultiView by Draper

 page 2 of 4

Motorized Roller/Fabric Removal

Reverse the instructions above under “Motorized Roller/Fabric Installation”
for removal of the unit.

Operation

When screen and masking are first operated, 

be cautious! 

Cycle unit down 

and up several times to confirm satisfactory operation. Factory adjusted limit 
switches should automatically stop screen or masking when fully down or 
fully up. Separate controls operate screen and masking motors, unless the 
Access/MultiView Control is used.

220V SINGLE STATION CONTROL (2 standard)—

3-position UP-OFF-OWN

switches permit operation to be stopped at any point.

220V MULTIPLE STATION CONTROL

—(Not CE Approved) Switches are 

similar in appearance to 220V Single Station Control. Screen stops when 
switch is released and may be restarted in either direction. 

ACCESS/MULTIVIEW CONTROL

—This 24V control permits both motors to 

be operated from a single switch, which is equipped with two sets of UP-0FF-
DOWN buttons.

24V MULTIPLE STATION CONTRO

L—Separate three-button UP-STOP-

DOWN switches for each motor, stop at any point desired, operate in any 
sequence.

220V & 12V VIDEO INTERfACE CONTROL

—(Not CE Approved) Allows 

screen to be controlled by a trigger signal—when the signal comes on, the 
screen descends automatically. Two versions: Model VIC220 integrates screen 
operation with a DRAPER video projector lift or a video projector or tuner with 
a 220V switched outlet. Model VIC12 interfaces with a 12V switched outlet. 
Both available with an override switch (VIC–OS), permitting independent 
operation. VIC–OS not available with factory installed VIC220 & VIC12. 

KEY OPERATED SWITCHING

—(Not CE Approved) Two kinds of key-

operated switches are optionally available with this unit. 

1

 The key-operated power supply switch controls power to the screen and  

  switches. When it is “off”, the switches will not operate screen.  
  Key may be removed from the switch in either “on” or “off” position.

2

 A three-position key switch permits the screen to be operated directly by  

  key. In this case, the screen’s operator must always have a key.

Motor roller 

assembly

Retaining 

clip

Washer

Idler end roller 

mounting bracket

Connect the electrical plugs from the motors to the mating sockets on the
junction boxes.
Reinstall the bottom access panel as previously described.

www.draperinc.com

(765) 987-7999

Reviews: