Draper 99074 Manual Download Page 4

- 4 -

3. WARRANTY

3.1 WARRANTY

Draper tools have been carefully tested and inspected before shipment and are guaranteed to be 

free from defective materials and workmanship.

Should the tool develop a fault, please return the complete tool to your nearest distributor or 

contact

Draper Tools Limited, Chandler's Ford, Eastleigh, Hampshire, SO53 1YF. England.

Telephone Sales Desk: (023) 8049 4333 or Product Help Line (023) 8049 4344.

A proof of purchase must be provided with the tool.

If upon inspection it is found that the fault occurring is due to defective materials or workmanship, 

repairs will be carried out free of charge. This warranty period covering parts & labour is 12 

months from the date of purchase except where tools are hired out when the warranty period is 90 

days from the date of purchase. This warranty does not apply to any consumable parts, any type 

of battery or normal wear and tear, nor does it cover any damage caused by misuse, careless or 

unsafe handling, alterations, accidents, or repairs attempted or made by any personnel other than 

the authorised Draper warranty repair agent.

Note: If the tool is found not to be within the terms of warranty, repairs and carriage charges will 

be quoted and made accordingly.

This warranty applies in lieu of any other warranty expressed or implied and variations of its terms 

are not authorised.

Your Draper warranty is not effective unless you can produce upon request a dated receipt or 

invoice to verify your proof of purchase within the warranty period.

Please note that this warranty is an additional benefit and does not affect your statutory rights.

Draper Tools Limited.

Summary of Contents for 99074

Page 1: ...has been designed and contains all the necessary information to ensure its correct and safe use By following all the general safety instructions contained in this manual it will ensure both product a...

Page 2: ...S SAFETY CONTENT WARNING Information that draws attention to the risk of injury or death CAUTION Information that draws attention to the risk of damage to the product or surroundings 1 4 COPYRIGHT NO...

Page 3: ...5 2 REDUCING RISK OF ELECTRICAL SHOCK OR ELECTROCUTION 6 5 3 PREVENTING INJURY 6 5 4 SAFETY PRECAUTIONS 7 6 TECHNICAL DESCRIPTION 6 1 IDENTIFICATION 8 7 UNPACKING AND CHECKING 7 1 PACKAGING 9 7 2 WHAT...

Page 4: ...tools are hired out when the warranty period is 90 days from the date of purchase This warranty does not apply to any consumable parts any type of battery or normal wear and tear nor does it cover any...

Page 5: ...SI 11 03 Bar Built in pressure switch 130 PSI On 8 96 Bar 155 PSI Off 10 69 Bar Auto Reset Thermal Protection Yes Hose 1 4 PCL type Working length 7 6m Weight 5 92kg 4 3 HANDLING AND STORAGE Care must...

Page 6: ...ed near children This compressor will become HOT during and immediately after use Do not touch any part of this compressor with bare hands other than the ON OFF switch during and immediately after use...

Page 7: ...PSI rated working pressure extension hose Do not use aftermarket hoses with less than 200 13 79 Bar PSI working pressure Some aftermarket hoses may not be suitable for use with this air compressor due...

Page 8: ...1 4 3 2 6 5 6 1 IDENTIFICATION 6 TECHNICAL DESCRIPTION 8 1 Compressor on off switch 2 Crocodile clips 3 Air line coupling 4 Safety valve 5 Overload trip switch 6 Inlet filter...

Page 9: ...ions DO NOT OVER STRETCH THESE HOSES 7 Tyre inflator 8 Metal needle adaptor 9 Plastic adaptors 10 Coil hoses 11 Carry bag 7 1 PACKAGING Carefully remove the product from the packaging and examine it f...

Page 10: ...nflation the compressor may not restart This is completely normal since inline pressure is greater than cut on pressure of the pressure switch and less than cut off pressure of the pressure switch To...

Page 11: ...release the air to the desired pressure Once finished turn power switch on compressor to the off position Note To release excess pressure from the system turn off compressor and disconnect hose from c...

Page 12: ...ION INSTRUCTION Check to make sure air filter element is properly installed in your Inlet Air Filter Assembly Remove the temporary protective red plug from compressor s air inlet port Install inlet ai...

Page 13: ...is equipped with permanently lubricated maintenance free motor Never try to lubricate the compressor Regularly clean dust and dirt from compressor cooling fins and motor housing All repairs should be...

Page 14: ...of proper ventilation or ambient temperature is too high Compressor valves failed Move compressor to well ventilated area or area with lower ambient temperature Service or replace compressor Compress...

Page 15: ...e that it is disposed of according to national regulations Contact your local authority for details of collection schemes in your area In all circumstances Do not dispose of power tools with domestic...

Page 16: ...ice Warranty Repair Agent For aftersales servicing or warranty repairs please contact the Draper Tools help line for details of an agent in your local area YOUR DRAPER STOCKIST Published by Draper Too...