4. Product Introduction

Stock No.: 

98921

Part No.: 

DSWP1000A

Usage: 

Clear water

Rated voltage: 

220–240V AC

Rated frequency: 

50Hz

Rated input:

1,000W

Max. particle size: 

1mm

Max. duty cycle: 

4h on, 4h off

Output adaptor apertures (exterior):

 32, 25mm

Max. flow rate: 

5,500L/h

Max. head height: 

40m

Max. operating depth: 

7m

Max. water temperature: 

35°C

Min. water level: 

40mm*

Power cable length: 

10m

IP rating: 

IPX8

Appliance class: 

Class I

Weight: 

8kg

*This is the minimum level of water above the base of the 

pump at which the pump can safely operate. However, 

Draper Tools 

strongly recommends that the pump 

remains completely submerged throughout the entire 

operation. Operating the pump when it is not submerged 

may compromise the motor and housing.

– 5 –

EN

4.2 Specification

4.1 Scope

This product is a deep-water pump designed for 

submersion within the reservoir and is suitable for 

transferring clean water only in areas requiring a large 

head or high pressure. This pump is suitable for 

permanent and semi-permanent installations that do not 

require the pump to be in constant use, for example in 

locations where it is necessary to maintain a given level of 

water, or for temporary or emergency installations to lower 

excessively high water levels.
Clear water pumps are suitable for use in pumping clear 

water from pools and garden ponds where the water is not 

muddied by sediment or algae and contains no visible 

particles. Draper Tools recommends that clear water 

pumps are used

 ONLY in reservoirs that are completely 

free from debris.
Part of our core range, this product is suitable for regular 

use by enthusiasts and tradespersons alike. 
Important: This product is NOT suitable for continuous 

use, such as water circulation (water features, etc.). Using 

it in this way will invalidate your product warranty.
Important: Draper Tools strongly recommends this 

product is used to lower water levels 

ONLY and NOT for 

completely draining reservoirs. We recommend that the 

pump remains 

COMPLETELY submerged throughout the 

entire operation to ensure that the motor remains cool and 

does not overheat. If the motor overheats, it may become 

damaged and may compromise the structure of the pump.
Important: This product is NOT suitable for permanent 

installation in fish ponds or any other reservoir containing 

water mixed with chemicals or other acidic contaminants, 

including salt water.
Where the pump is used temporarily in a fish pond, Draper 

Tools 

STRONGLY recommends that the fish are removed 

for the duration of operation or a guard is placed around 

the pump inlet to prevent fish from being drawn into the 

mechanism. Guards must not prevent water from being 

drawn into the pump or obstruct the impeller in any way. 

DO NOT use this product in fish ponds where the fish are 

small enough to access the impeller.

 

WARNING! This product is not a toy and must be 

respected.

Read this manual in full before attempting to assemble, 

operate or maintain the product, and retain it for later 

use.

Summary of Contents for 98921

Page 1: ...98921 EN Version 2 September 2022 230V SUBMERSIBLE WITH FLOAT SWITCH DEEP WATER WELL PUMP ...

Page 2: ...ted No part of this manual may be stored in a retrieval system or transmitted in any other form or means without written permission from Draper Tools Limited In all cases this copyright notice must remain intact 1 Preface 2 These are the original product instructions This document is part of the product retain it for the life of the product passing it on to subsequent holders Read this manual in f...

Page 3: ...Submersible Water Pump 6 5 3 Connection to the Power Supply 7 5 4 Residual Risk 7 6 Identification and Unpacking 8 6 1 Product Overview 8 6 2 Packaging 9 7 Preparation Instructions 10 7 1 Using the Outlet Adaptors 10 7 2 Installation and Placement 10 7 3 Positioning the Float Switch 11 8 Operating Instructions 12 8 1 Switching the Pump On and Off 12 8 2 Pumping Distance and Volume 12 9 Maintenance...

Page 4: ...ccidents or repairs attempted or made by any personnel other than the authorised Draper Tools repair agent In all cases to make a claim for faulty workmanship or materials within the standard warranty period please contact or return the product to the place of purchase Proof of purchase may be required If the place of purchase is no longer trading or if you experience any difficulties with your wa...

Page 5: ...tains no visible particles Draper Tools recommends that clear water pumps are used ONLY in reservoirs that are completely free from debris Part of our core range this product is suitable for regular use by enthusiasts and tradespersons alike Important This product is NOT suitable for continuous use such as water circulation water features etc Using it in this way will invalidate your product warra...

Page 6: ...and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved Children must not play with the appliance Cleaning and user maintenance must not be performed by children without supervision NEVER use this product to pump corrosive flammable or explosive liquids or solvents This is a Class I appliance This produc...

Page 7: ...ect rating approved to BS 1363 A and ASTA or BS Kite marked ASTA BSI Replacement of the fuse should only be performed by suitably qualified personnel If the power supply cord is damaged it must be replaced by Draper Tools an authorised service agent or similarly qualified personnel in order to avoid a hazard The damaged or incomplete plug when cut from the cable shall be disabled to prevent connec...

Page 8: ...visit drapertools com for our full range of accessories and consumables 6 1 Product Overview Carefully remove the product from the packaging and examine it for any signs of damage that may have occurred during shipment If any part is damaged or missing do not attempt to use the product Please contact the Draper Helpline contact details can be found at the back of this manual 2 5 4 3 7 1 8 6 9 ...

Page 9: ...packaging for the duration of the warranty period for reference should the product need to be returned for repair WARNING Keep packaging materials out of reach of children Dispose of packaging correctly and responsibly and in accordance with local regulations 9 EN ...

Page 10: ...ses The chosen layflat hose should be secured to the adaptor using a suitable retaining clip 7 2 Installation and Placement The pump may only be used to move water containing debris of up to the rated maximum particle size Ensure that all debris exceeding this size is removed from the reservoir before operation as it may cause significant damage to the impeller and pump Important Draper Tools reco...

Page 11: ...mp recess will reduce the change in depth required to switch the pump on and off The pump will switch on at a lower water level than when the distance is longer The pump will switch off at a higher water level than when the distance is longer A longer distance between the float switch and the cable clamp recess will increase the change in depth required to switch the pump on and off The pump will ...

Page 12: ...itch in a downwards vertical position to separate the bearing from the cable and break the circuit or switch off and disconnect the mains power The pump is also fitted with a thermal overload that will cause it to stop automatically if its internal temperature becomes too hot When this occurs disconnect the pump from mains power allow it to cool and investigate possible causes of overheating Once ...

Page 13: ...build up of obstructive debris If the pump is used frequently in water containing debris that is likely to accumulate on the pump body rinse it thoroughly after every use Clean the outside of the pump with a dry or damp cloth ONLY DO NOT use solvents or aggressive chemicals to clean this product as they may damage plastic and insulated parts Ensure that the product is dry before storage Store this...

Page 14: ...impellor housing The outlet or hose adaptor is clogged Remove the hose adaptor and check it and the pump outlet for obstructions The head height exceeds the capabilities of the pump Reduce the vertical distance that the water must be pumped An air bubble has been formed inside the pump Remove the pump from the reservoir and resubmerge it at an angle shaking it as it is lowered to disperse any air ...

Page 15: ...the product of any water and debris before returning it to Draper Tools or its authorised agent A charge may be applicable if Draper Tools must clean the product before investigating a fault Draper Tools will not service any product that has been used to pump sewage slurry or other such materials All returns must be thoroughly cleaned and drained before delivery to Draper Tools or their authorised...

Page 16: ...ith and without reducing adaptor 1mm Max particle size Warning Not for use in fish ponds IP rated for continuous submersion of over 1m Class I appliance WEEE Waste Electrical Electronic Equipment Do not dispose of Waste Electrical Electronic Equipment in with domestic rubbish European conformity UK Conformity Assessed 16 ...

Page 17: ...Notes 17 EN ...

Page 18: ...raper Tools Draper Tools Limited Hursley Road Chandler s Ford Eastleigh Hampshire SO53 1YF UK Website drapertools com Email sales drapertools com Product Helpline 44 0 23 8049 4344 Telephone Sales Desk 44 0 23 8049 4333 General Enquiries 44 0 23 8026 6355 General Fax 44 0 23 8026 0784 Please contact the Draper Tools Product Helpline for repair and servicing enquiries ...