Summary of Contents for 98921

Page 1: ...98921 EN Version 2 September 2022 230V SUBMERSIBLE WITH FLOAT SWITCH DEEP WATER WELL PUMP ...

Page 2: ...ted No part of this manual may be stored in a retrieval system or transmitted in any other form or means without written permission from Draper Tools Limited In all cases this copyright notice must remain intact 1 Preface 2 These are the original product instructions This document is part of the product retain it for the life of the product passing it on to subsequent holders Read this manual in f...

Page 3: ...Submersible Water Pump 6 5 3 Connection to the Power Supply 7 5 4 Residual Risk 7 6 Identification and Unpacking 8 6 1 Product Overview 8 6 2 Packaging 9 7 Preparation Instructions 10 7 1 Using the Outlet Adaptors 10 7 2 Installation and Placement 10 7 3 Positioning the Float Switch 11 8 Operating Instructions 12 8 1 Switching the Pump On and Off 12 8 2 Pumping Distance and Volume 12 9 Maintenance...

Page 4: ...ccidents or repairs attempted or made by any personnel other than the authorised Draper Tools repair agent In all cases to make a claim for faulty workmanship or materials within the standard warranty period please contact or return the product to the place of purchase Proof of purchase may be required If the place of purchase is no longer trading or if you experience any difficulties with your wa...

Page 5: ...tains no visible particles Draper Tools recommends that clear water pumps are used ONLY in reservoirs that are completely free from debris Part of our core range this product is suitable for regular use by enthusiasts and tradespersons alike Important This product is NOT suitable for continuous use such as water circulation water features etc Using it in this way will invalidate your product warra...

Page 6: ...and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved Children must not play with the appliance Cleaning and user maintenance must not be performed by children without supervision NEVER use this product to pump corrosive flammable or explosive liquids or solvents This is a Class I appliance This produc...

Page 7: ...ect rating approved to BS 1363 A and ASTA or BS Kite marked ASTA BSI Replacement of the fuse should only be performed by suitably qualified personnel If the power supply cord is damaged it must be replaced by Draper Tools an authorised service agent or similarly qualified personnel in order to avoid a hazard The damaged or incomplete plug when cut from the cable shall be disabled to prevent connec...

Page 8: ...visit drapertools com for our full range of accessories and consumables 6 1 Product Overview Carefully remove the product from the packaging and examine it for any signs of damage that may have occurred during shipment If any part is damaged or missing do not attempt to use the product Please contact the Draper Helpline contact details can be found at the back of this manual 2 5 4 3 7 1 8 6 9 ...

Page 9: ...packaging for the duration of the warranty period for reference should the product need to be returned for repair WARNING Keep packaging materials out of reach of children Dispose of packaging correctly and responsibly and in accordance with local regulations 9 EN ...

Page 10: ...ses The chosen layflat hose should be secured to the adaptor using a suitable retaining clip 7 2 Installation and Placement The pump may only be used to move water containing debris of up to the rated maximum particle size Ensure that all debris exceeding this size is removed from the reservoir before operation as it may cause significant damage to the impeller and pump Important Draper Tools reco...

Page 11: ...mp recess will reduce the change in depth required to switch the pump on and off The pump will switch on at a lower water level than when the distance is longer The pump will switch off at a higher water level than when the distance is longer A longer distance between the float switch and the cable clamp recess will increase the change in depth required to switch the pump on and off The pump will ...

Page 12: ...itch in a downwards vertical position to separate the bearing from the cable and break the circuit or switch off and disconnect the mains power The pump is also fitted with a thermal overload that will cause it to stop automatically if its internal temperature becomes too hot When this occurs disconnect the pump from mains power allow it to cool and investigate possible causes of overheating Once ...

Page 13: ...build up of obstructive debris If the pump is used frequently in water containing debris that is likely to accumulate on the pump body rinse it thoroughly after every use Clean the outside of the pump with a dry or damp cloth ONLY DO NOT use solvents or aggressive chemicals to clean this product as they may damage plastic and insulated parts Ensure that the product is dry before storage Store this...

Page 14: ...impellor housing The outlet or hose adaptor is clogged Remove the hose adaptor and check it and the pump outlet for obstructions The head height exceeds the capabilities of the pump Reduce the vertical distance that the water must be pumped An air bubble has been formed inside the pump Remove the pump from the reservoir and resubmerge it at an angle shaking it as it is lowered to disperse any air ...

Page 15: ...the product of any water and debris before returning it to Draper Tools or its authorised agent A charge may be applicable if Draper Tools must clean the product before investigating a fault Draper Tools will not service any product that has been used to pump sewage slurry or other such materials All returns must be thoroughly cleaned and drained before delivery to Draper Tools or their authorised...

Page 16: ...ith and without reducing adaptor 1mm Max particle size Warning Not for use in fish ponds IP rated for continuous submersion of over 1m Class I appliance WEEE Waste Electrical Electronic Equipment Do not dispose of Waste Electrical Electronic Equipment in with domestic rubbish European conformity UK Conformity Assessed 16 ...

Page 17: ...Notes 17 EN ...

Page 18: ...raper Tools Draper Tools Limited Hursley Road Chandler s Ford Eastleigh Hampshire SO53 1YF UK Website drapertools com Email sales drapertools com Product Helpline 44 0 23 8049 4344 Telephone Sales Desk 44 0 23 8049 4333 General Enquiries 44 0 23 8026 6355 General Fax 44 0 23 8026 0784 Please contact the Draper Tools Product Helpline for repair and servicing enquiries ...

Reviews: