background image

 

    

DRAPER TOOLS LIMITED,

Hursley Road, Chandler's Ford, Eastleigh, Hants. SO53 1YF. U.K.

Helpline: (023) 8049 4344.

Sales Desk: (023) 8049 4333.

General Enquiries: (023) 8026 6355.

Fax: (023) 8026 0784.

©Published by Draper Tools Ltd.

No part of this publication may be reproduced,

stored in a retrieval system or transmitted in

any form or by any means, electronic, mechanical

photocopying, recording or otherwise without prior

permission in writing from Draper Tools Ltd.

YOUR DRAPER STOCKIST

http://www.draper.co.uk
e-mail: [email protected]

 

    

25 & 50 LITRE

COMPRESSORS

 

STOCK Nos. 77760

 PART Nos.DA25/190

77759

DA50/190

GENERAL INFORMATION

This manual has been compiled by Draper Tools and is an integrated part of the product with which it is enclosed 
and should be kept with it for future references.
This manual describes the purpose for which the product has been designed and contains all the necessary 
information to ensure its correct and safe use. We recommend that this manual is read before any operation or, 
before performing any kind of adjustment to the product and prior to any maintenance tasks. By following all the 
general safety instructions contained in this manual, it will ensure both product and operator safety, together with 
longer life of the tool itself.
All photographs and drawings in this manual are supplied by Draper Tools to help illustrate the operation of the 
product.
Whilst every effort has been made to ensure accuracy of information contained in this manual, the Draper Tools 
policy of continuous improvement determines the right to make modifications without prior warning.

01/2005

• INSTRUCTIONS •

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY TO ENSURE THE

SAFE AND EFFECTIVE USE OF THIS TOOL.

Summary of Contents for 77759

Page 1: ...any kind of adjustment to the product and prior to any maintenance tasks By following all the general safety instructions contained in this manual it will ensure both product and operator safety together with longer life of the tool itself All photographs and drawings in this manual are supplied by Draper Tools to help illustrate the operation of the product Whilst every effort has been made to en...

Page 2: ...ich this declaration relates is in conformity with the following directive s 98 37 EC 97 23 EC 2000 14 EC 73 23 EEC 89 336 EEC 87 404 EEC JOHN DRAPER Managing Director 16 07 2004 25 and 50 LITRE COMPRESSORS STOCK Nos 77760 PART Nos DA25 190 77759 DA50 190 CONTENTS Contents Declaration 1 Specification Guarantee 2 Power Supply 3 General Safety Instructions 4 Getting to KnowYour Compressor 5 Operatio...

Page 3: ...the machine develop any fault please return the complete tool to your nearest authorized warranty repair agent or contact Draper Tools Limited Chandler s Ford Eastleigh Hampshire SO53 1YF England Telephone 023 8026 6355 If upon inspection it is found that the fault occurring is due to defective materials or workmanship repairs will be carried out free of charge This guarantee does not apply to nor...

Page 4: ...nd the correct type of plug fitted See below WARNING A plug with bare flexible wires exposed is hazardous if engaged in a live power socket outlet WARNING THIS APPLIANCE MUST BE EARTHED The mains lead is coloured Green and Yellow Earth Blue Neutral and Brown Live As these colours may not correspond with the coloured markings identifying the terminals in your plug proceed as follows The wire which ...

Page 5: ...ining or replacing damaged parts ALWAYS disconnect the compressor from the power supply 5 EARTH This compressor is equipped with an approved 3 core power cable The green and yellow conductor in the core is the earth wire NEVER connect the yellow and green wire to a live terminal 6 AVOID DANGEROUS ENVIRONMENTS Do not use the compressor in damp or wet locations or expose it to rain Keep the work are...

Page 6: ...Regulator 5 UNPACKING After removing the packing material make sure the product is in perfect condition and that there are no visible damaged parts If in doubt do not use the compressor and contact the dealer from whom it was purchased The packaging materials plastic bags polystyrene etc must be disposed of in an appropriate refuse collection container These materials must not be left within the r...

Page 7: ...ed see page 10 When the installation procedure is complete the compressor is ready for use Make sure the pressure switch is positioned OFF Switch on the power then position the pressure switch to the ON position to start the compressor Fig 2 When starting the compressor for the first time leave it running for about 10 minutes with the drain cock A open Fig 3 DA25 190 does not have a tap Instead ru...

Page 8: ...ine from the power supply and turn the adjustment bolt clockwise 3 turns and replace the switch cover Run the compressor up to the desired capacity for the pressure switch to be set do not let the compressor run past its maximum pressure At this point turn the mains power off and disconnect from the supply Remove the cover and adjust the bolt anti clockwise gently until the switch is heard to rele...

Page 9: ...ed as follows Allow three minutes Position the pressure switch to 0 OFF Manually reset the thermal cut out Position the pressure switch to 1 ON If you restart the compressor and the overload cut out releases again turn the main switch to position 0 OFF unplug the equipment and contact the Authorized Service Centre If disconnection is required from the air tap assembly ensure the tap is fully close...

Page 10: ...e the oil does not drop below the minimum so as to avoid any damage or seizure Drain condensation while the tank is pressurised by opening the valve I located under the tank Open the valve by turning it anti clockwise Fig 8 with a container under the valve Keep the compressor in a position to allow all condensation to flow out completely MONTHLY OPERATIONS OR MORE FREQUENTLY IF THE COMPRESSOR OPER...

Page 11: ...commended oils with ISO 100 viscosity for compressors in accordance with DIN51506 VDL 100 E Standards and ISO6521 L DAC Specifications suitable for room temperature ranging from 6 C and 25 C AGIP DICREA100 API CM 8X BP ENERGOL CS100 CASTROL AIRCOL PD100 ESSO EXX OLUB H150 IP CALATIA OIL ISO 100 MOBIL RARUS 427 FINA EOLAN AC 100 SHELL COREMA OIL H100 TOTAL CORTUSA 100 Use oils with an ISO 46 68 vis...

Page 12: ... Sales Service The pressure switch valve leaks when the compressor is idle Non return valve seal defective Contact your Local Service Centre The compressor stopped and does not start Overload cut out tripped See Page 8 The compressor does not stop even though the max pressure allowed has been reached the safety valve operates Incorrect Setting Contact your Local Service Centre The compressor does ...

Page 13: ...NOTES 12 ...

Page 14: ...NOTES 13 ...

Page 15: ...NOTES 14 ...

Page 16: ...355 Fax 023 8026 0784 Published by Draper Tools Ltd No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without prior permission in writing from Draper Tools Ltd YOUR DRAPER STOCKIST http www draper co uk e mail sales drapertools com ...

Reviews: